Skip to main content
v2026.11,986 entries · CC-BY 4.0

SK-OV-3 Cell Line: Identity and Research Limits

SK-OV-3 identity, derivative names, authentication records and the evidence needed to justify an ovarian cancer model.

Written and maintained by CASRAI Editorial Board

Published

On this page

The SK-OV-3 cell line is a human ovarian adenocarcinoma research model derived from ascitic fluid, with adherent growth and epithelial-like morphology. Also called SKOV3, it is catalogued as ATCC HTB-77 and Cellosaurus CVCL_0532. Its ovarian origin, authenticated identity and suitability for a particular cancer subtype are separate questions.

Short answer

SK-OV-3 is useful to recognize as both a biological model and a named research material. A catalogue record establishes which line a supplier describes; an authentication result concerns the sample tested; a model-comparison study addresses the biological question that sample can represent. These kinds of evidence answer different questions and should remain distinguishable in a laboratory record.

The central qualification is subtype fit. In their genomic comparison of ovarian cancer models, Domcke and colleagues found SK-OV-3 poorly suited to represent high-grade serous ovarian cancer, or HGSOC. That finding does not erase the line’s ovarian origin or every possible research application. It means that the label “ovarian cancer cell line” alone does not justify a claim that an experiment models HGSOC.

Definition and scope

ATCC describes SK-OV-3 as a human line from a 64-year-old female with ovarian adenocarcinoma. Its tissue field includes ovary and ascites. The originating institution, Memorial Sloan Kettering Cancer Center, identifies ascites as the source material and gives 1973 as the year of establishment. ECACC independently describes the ascitic-fluid origin. Thus “ovarian” identifies the cancer context; it should not be expanded into an unsupported statement that the culture came directly from a solid ovarian biopsy.

The names SK-OV-3, SKOV-3 and SKOV3 refer to the parental line in the relevant repository and registry records. Cellosaurus provides the accession CVCL_0532 and the citation identifier RRID:CVCL_0532. ATCC’s HTB-77 and ECACC’s 91091004 identify their respective catalogue entries. Keeping the repository identifier alongside the biological name helps distinguish a documented source from an informal label on a vial.

These identifiers have different roles. A supplier number points to a repository record; a registry accession brings together names, cross-references and relationships. Neither is a test result for a particular laboratory stock. A methods description therefore benefits from retaining both the source identifier and the stock’s own quality records, rather than treating the registry entry as evidence that a local culture has been authenticated.

ATCC restricts the material to laboratory research and excludes diagnostic and therapeutic use. ECACC likewise describes its cultures as research materials. The explanations here concern laboratory interpretation and documentation, not diagnosis, treatment or clinical validation.

How SK-OV-3 is used in practice

ATCC lists SK-OV-3 as a suitable transfection host and includes 3D cell culture among its applications. Memorial Sloan Kettering describes colony formation in soft agar. These are specific documented uses or properties; they should not be converted into a guarantee that every experimental system will behave identically.

For a researcher, the useful distinction is between an assay performed in SK-OV-3 and a conclusion about a disease population. A result can accurately describe a response measured in this line while requiring additional evidence before it supports a claim about a particular ovarian cancer subtype. The line name belongs in the experimental description; the disease-model justification belongs in the rationale.

Ovarian origin and HGSOC model suitability

Domcke and colleagues compared 47 ovarian cancer cell lines with tumour data using DNA copy-number changes, mutations and gene expression. Their analysis identified substantial differences between commonly used lines and HGSOC tumours. SK-OV-3 was among the models they judged poorly suited for HGSOC, despite its frequent use.

The authors also identified lines with closer genomic resemblance to HGSOC, including KURAMOCHI and OVSAHO. Their analysis supports selecting models against the characteristics relevant to the research question. It does not establish a universal replacement line or make a genomic similarity score sufficient for every assay. A study of a specific alteration and a study claiming broad subtype representation require different justifications.

Molecular annotations need their source context

Cellosaurus lists the TP53 frameshift p.Ser90Profs*33, corresponding to c.267delC, for SK-OV-3. This differs from the TP53 characterization reported in the older Domcke analysis. The sound reading is to preserve that disagreement rather than merge the two records into a single supposedly settled genotype.

A laboratory investigating TP53 should identify the molecular dataset behind its rationale and document the stock used. The older study’s broader conclusion about HGSOC suitability can be reported as that study’s finding without repeating its TP53 statement as a universal current fact. Equally, a registry annotation is not a measurement of the cells in a particular experiment. This distinction prevents a literature citation from being mistaken for stock-specific characterization.

The important distinctions are the parental line, named derivatives and independent ovarian cancer models. Cellosaurus lists child records for SK-OV-3, including luciferase-labelled derivatives and separately named resistant derivatives. Those relationships explain why a suffix can carry biological information instead of being a cosmetic variation in spelling.

A parental SK-OV-3 culture and a reporter derivative should therefore retain their separate names in experimental records. A registry relationship establishes ancestry; it does not establish that two stocks have identical engineering, selection history or assay behaviour. Likewise, an independently established ovarian cancer line is a comparator, not a synonym for SK-OV-3.

Authentication and characterization also differ. ICLAC’s human-cell authentication guide explains that STR profiling cannot distinguish lines from the same donor or separately subcloned lines. A matching STR profile can support donor identity while leaving a derivative-specific question unresolved. Reporter status or a named resistant phenotype needs evidence appropriate to that property, rather than being inferred from the shared parental identity.

Growth descriptions belong in this same framework. ATCC and ECACC both describe an adherent epithelial culture. Cellosaurus gathers different published doubling-time observations. Those observations are records from different sources, not one universal doubling time that can be assigned to every SK-OV-3 stock. The name of a line does not remove the need to report the conditions under which a growth measurement was made.

Where it matters for labs and supply documentation

For laboratory planning, the most useful source comparison concerns documentation, compatibility and the identity of the material being used. The evidence checklist in the data table below brings together repository, registry, authentication and model-comparison records. Each row identifies the kind of claim its source actually supports; the table is not a culture protocol.

Repository documents describe particular materials

ATCC and ECACC both name McCoy’s 5a in their SK-OV-3 culture documentation, but their published serum formulations differ. That difference is a reason to retain the source-specific formulation in the experimental record. It does not support combining selected details from the two pages into a third, supposedly universal recipe. ATCC expressly warns that changing recommended media or reagents may affect recovery, growth or function.

ATCC also provides lot-based certificate retrieval. A certificate of analysis belongs with the material and lot it describes. A product-page specification, a lot certificate and a later in-house test should remain identifiable as separate records. Otherwise, a quality result for supplied material can be mistaken for an observation made on a working culture after laboratory handling.

Identity and contamination are separate checks

ICLAC’s institutional practices distinguish registry checks, STR genotyping, detection of non-human species and mycoplasma testing. This is why a single “quality checked” label is less informative than naming the checks and their results. A mycoplasma result does not establish the donor identity of a human culture, and an identity match does not substitute for a contamination assessment.

ATCC publishes an STR reference profile alongside separate microbial quality specifications. For the broader interpretation of those records, see cell line authentication and STR profiling. ICLAC’s 2023 guide cites ASN-0002-2022 and specifies at least 13 nuclear STR loci plus amelogenin. An isolated matching marker should not be presented as a complete authentication result.

The choice and interpretation of a contamination assay are a different topic, covered in the comparison of mycoplasma testing methods. Keeping that result separate from authentication makes a methods record more explicit about what was tested, instead of implying that one assay answered both questions.

Safety classifications retain their framework

The source documents also illustrate why safety labels need attribution. ATCC lists SK-OV-3 as BSL 1 under its material risk assessment. ECACC lists ACDP Hazard Group 2 and explains that it routinely handles cell lines at containment level 2 unless otherwise specified. These labels arise in different frameworks; they should not be presented as interchangeable instructions.

Both repositories place responsibility on the user to meet applicable institutional and national requirements. The practical documentation task is to retain the relevant supplier information and the institution’s risk assessment. Selecting the less restrictive label from another repository is not a substitute for that assessment.

Illustrative composite: separating a methods claim

Consider a fictional laboratory preparing a report on a luciferase-labelled SK-OV-3 derivative. This illustrative composite describes no real experiment. Writing only “SKOV3 cells were authenticated” would leave several different matters compressed into one phrase: the source of the parental material, the derivative’s identity, the sample tested and the intended disease-model claim.

A clearer record would distinguish the supplier and catalogue reference, the complete derivative designation, the stock’s STR report, its separate mycoplasma result and the evidence for the reporter property. If the report claims to model HGSOC, that rationale needs its own supporting comparison. This organization follows ICLAC’s distinction between donor authentication and subclone identity, together with Domcke’s distinction between ovarian origin and subtype resemblance.

Common misunderstandings

“A different spelling means a different line.” SKOV3 and SK-OV-3 are recognized aliases in the registry. A derivative suffix is different: it can identify a separately recorded material. Alias matching and derivative identification should not be collapsed into the same decision.

“Epithelial morphology establishes the subtype.” The repositories describe morphology, while the genomic-comparison study evaluates resemblance to HGSOC. The first observation does not supply the second conclusion. Preserve the distinction when writing an introduction, figure legend or study rationale.

“STR authentication proves the experimental phenotype.” ICLAC explicitly describes the limits of STR for same-donor cultures and subclones. Authentication supports an identity claim within those limits; it does not establish a reporter signal, resistance phenotype or the suitability of a disease model.

“A repository QC result describes the current working culture.” A source’s specifications and a laboratory’s own test concern different records and samples. Reporting their provenance avoids extending a supplier result beyond what it documents. Similarly, conflicting molecular annotations should retain their sources rather than becoming an unsourced consensus statement.

Sources

Data: SK-OV-3 identity and research evidence checklist

An original cross-source compilation of SK-OV-3 repository identifiers, registry relationships, provenance, model-comparison findings and authentication guidance. Each row names the document behind its finding; the rows describe different evidence roles rather than a culture protocol.

SK-OV-3 identity and research evidence checklist
Evidence recordIdentifier or documentDocumented findingSource URL
Source repositoryATCC HTB-77Human ovarian adenocarcinoma line; adherent growth; epithelial morphology; transfection host.https://www.atcc.org/products/htb-77
Identity registryCellosaurus CVCL_0532SKOV3 and SKOV-3 are aliases; the record links repository accessions and separately named derivatives.https://www.cellosaurus.org/CVCL_0532
Independent repositoryECACC 91091004Human ovarian tumour ascitic-fluid origin; epithelial cell type; adherent growth; STR reference profile.https://www.culturecollections.org.uk/nop/product/sk-ov-3
Originating institutionMSK SK1980-528Established in 1973 from ascites of a 64-year-old female with ovarian adenocarcinoma.https://www.mskcc.org/research-advantage/support/technology/tangible-material/human-ovarian-cell-line-sk-ov-3
Disease-model comparisonDomcke et al., Nature Communications 4:2126 (2013)Genomic analysis of 47 ovarian cancer lines judged SK-OV-3 poorly suited as an HGSOC model.https://www.nature.com/articles/ncomms3126
Distinct quality assessmentsICLAC institutional practicesRegistry identity checks, STR genotyping, non-human species detection and mycoplasma testing are listed separately.https://iclac.org/resources/best-lab-practices/
Authentication scopeICLAC guide, 2 March 2023; ASN-0002-2022At least 13 nuclear STR loci plus amelogenin; STR does not distinguish same-donor lines or separately subcloned lines.https://iclac.org/wp-content/uploads/ICLAC_Guide-to-Human-Cell-Line-Authentication_02-Mar-2023.pdf

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about SK-OV-3 Cell Line: Identity and Research Limits

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →