Skip to main content
v2026.11,986 entries · CC-BY 4.0

Small RNA Sequencing: Workflow, Library Prep and Bias

How small RNA sequencing works: library prep chemistries compared, ligation blind spots, adapter dimers and the analysis pipeline.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Small RNA sequencing (small RNA-seq) is a next-generation sequencing method that profiles short non-coding RNAs, most often microRNAs of about 22 nucleotides, by converting them into an adapter-flanked cDNA library and reading the whole molecule in a single read. It differs from standard mRNA sequencing because the library chemistry, size selection, read configuration and analysis are all built around very short inserts.

What counts as small RNA

Illumina’s technique page names microRNA (miRNA), small interfering RNA (siRNA), piwi-interacting RNA (piRNA) and other small non-coding RNAs as the classes this approach profiles. The page does not give one size range for the group. A general reference article on the method describes small RNA loosely as roughly 20 to 200 nucleotides, while the miRNA class at the centre of most projects is about 22 nucleotides long, according to a 2021 review in Diagnostics (Benesova, Kubista and Valihrach).

Because miRNAs are so short, a sequencing read of ordinary length covers the entire molecule plus the adapters. That single fact explains most of the practical differences from mRNA sequencing: the recommended read type, the kit requirements and the way adapter artefacts show up in the data. Annotation of miRNA sequences is curated in miRBase; the Diagnostics review cites miRBase release 22 as listing more than 38,000 miRNAs across 271 organisms, including 1,917 human miRNAs.

The same review notes that isomiRs, biologically active variants of a miRNA with different 5′ or 3′ ends, are part of what the method can resolve, which is one reason read-level data is reported rather than only gene-level counts.

How small RNA sequencing works, from sample to reads

The review describes the workflow as three stages: RNA isolation, cDNA library construction and sequencing. Each stage has choices that matter for small RNA specifically.

1. RNA isolation

The review states that analysing total RNA is usually preferred over a dedicated small RNA enrichment step, because enrichment can cause losses and isolation-specific bias. It cites a plasma comparison in which a total RNA protocol gave a higher proportion of miRNA reads and more detected miRNAs than an enrichment protocol. For low-concentration samples such as liquid biopsies, the review says RT-qPCR and small RNA-seq cope with low input better than microarrays. Extracellular vesicle work follows the same logic; see the CASRAI guide to exosome RNA for what that sample type adds.

2. Library construction

Illumina states that total RNA and mRNA kits do not retain the short fragments through their bead cleanups, so small RNAs need a dedicated small RNA library preparation. In the most common design, adapters are ligated to both ends of the RNA, the product is reverse transcribed and the cDNA is amplified by PCR. The chemistry choices are compared in the data table below.

3. Sequencing

Illumina recommends single-end sequencing for small RNA-seq and says paired-end reads offer no advantage, since the full insert is captured in one read. The same page describes its DRAGEN miRNA pipeline as aligning and quantifying miRNAs and other small RNAs from total RNA, including from FFPE tissue, blood and cell culture. Vendor input specifications are product-specific: Illumina’s miRNA Prep, for example, is described as optimised for 1 to 500 ng of total RNA, and that figure should not be read as a general requirement of the method.

Library preparation approaches compared

The data table below compares the four approaches the 2021 review distinguishes: traditional two-adaptor ligation, improved ligation with randomised adaptors, ligation-free methods and hybridisation platforms. Each cell traces to that review. Three points from it matter most when choosing between them.

  • Adaptor ligation is described as the most prominent source of bias, and the bias comes from the secondary structure of the miRNA and the adaptor. It is worst at low input.
  • No protocol outperformed all others on every metric, and of twelve comparative studies the authors identified, only three compared all of the available approaches.
  • Randomised-adaptor protocols were described as the most robust overall, and the Extracellular RNA Communication Consortium selected this approach as a standard.

Bias and blind spots: what ligation cannot see

A ligation-based library only contains RNAs whose ends are chemically compatible with the ligase. This is a structural limit, not a kit defect, and it is the part most vendor pages leave out. The table summarises what the sources state.

Feature of the RNA Effect on a ligation-based library Reported mitigation
Trimethylguanosine-capped snRNAs Not captured by ligation None stated in the review
2′-O-methylated 3′ end Reduced capture with standard enzymes Capturable with an optimised T4 RNA ligase 2 truncated enzyme (review)
5′-hydroxyl, 3′-phosphate or 2′,3′-cyclic phosphate ends Block ligation (general reference article) End-repair pretreatment with polynucleotide kinase (PNK), per the same article
Base modifications such as m1A, m3C, m1G and m22G Interfere with reverse transcription (general reference article) AlkB demethylase pretreatment, per the same article
Longer RNA fragments (for example lncRNA fragments) Also captured by ligation protocols and can crowd the library Bead-based size selection or PAGE (review)

For a project built to measure one specific RNA class, confirm that the class carries ends the chosen chemistry can ligate before reading differences between classes as biology.

Quality control and adapter dimers

The review warns that adapter dimers, the products of adapters ligating to each other, can consume a large share of reads when they are not removed. The problem is greatest in low-input samples, which need more PCR cycles. Its listed remedies are bead-based or gel purification, enzymatic removal of excess 3′ adaptor, chemically modified adaptors and blocking reverse transcription of dimers. The general reference article describes fragment-size QC before sequencing, by Bioanalyzer-type electrophoresis or gel, so the dimer peak is seen before sequencer time is spent on it.

A practical read-through of a library trace therefore asks three questions:

  1. Is there a dominant adapter-dimer peak, and is it larger than the insert peak?
  2. Does the insert-size distribution match the RNA class planned for, with a clear miRNA-sized peak?
  3. Do the index capacities fit the cohort? The review notes that most kits provide 96 indexes while some offer 48 or 24, which means extra sequencing runs for large cohorts.

Analysis pipeline outline

The general reference article summarises the analysis in a consistent order, and the Diagnostics review adds the points on bias correction and tool choice.

  1. Trim adapters and any unique molecular identifier (UMI) or index sequences from the reads.
  2. Run read-level quality control.
  3. Map the reads to a reference.
  4. Collapse duplicates, using UMIs where the library carries them.
  5. Quantify against annotation sets: miRBase for miRNA, with GtRNAdb for tRNA-derived fragments and GENCODE for other annotated RNAs.

UMIs help correct PCR amplification bias, but the review cautions that using randomised adaptor bases as UMIs can cause over-deduplication of highly abundant miRNAs. Check how a kit uses its randomised bases before deduplicating blindly; see unique molecular identifiers for the general concept. The review also reports more than 1,000 miRNA analysis tools and says this calls for experienced bioinformaticians, so document the chosen tools and versions. For target prediction after differential expression, see the TargetScan guide, and for the generic RNA-seq stages that small RNA-seq modifies, see RNA-seq steps.

Planning checklist for bench staff

  • Define the RNA class first, then check its end chemistry against the chemistry in the table above.
  • Prefer total RNA input to enrichment unless a source for your sample type says otherwise.
  • Choose single-end reads, as Illumina recommends.
  • Include a plan to detect and remove adapter dimers, and record the library trace.
  • Check the index capacity against the number of samples before ordering.
  • Consider synthetic equimolar standards, which the review says are used to measure ligation bias.
  • Plan RT-qPCR validation for key findings; the review calls RT-qPCR the gold standard for targeted miRNA analysis.

Sequencing versus RT-qPCR and probe-based assays

The review frames the choice by the question being asked. RT-qPCR is described as the gold standard for targeted miRNA analysis, so it suits a short list of known miRNAs. Small RNA-seq reads every compatible molecule in the library, so it suits discovery of novel miRNAs, isomiRs and other small RNA classes, and profiling of many miRNAs at once. Probe-based hybridisation panels sit between the two: they measure predesigned targets without a ligation and PCR library, but they cannot report anything outside the probe set. A common design is to profile with small RNA-seq and then confirm the few findings that carry the conclusion by RT-qPCR; the CASRAI pages on RNA-seq steps cover the general sequencing logic that this workflow shares.

Low-input samples change the balance. The review notes that biofluid samples such as plasma carry few miRNAs, that more PCR cycles are needed as input falls, and that more cycles raise both amplification bias and the share of reads lost to adapter dimers. Planning input, cycle number and cleanup together, rather than as separate choices, is the practical consequence.

Reporting what was done

Because the results depend on chemistry choices, the methods section of a paper or core-facility report should name the library preparation approach (ligation design, randomised adaptors, UMIs or hybridisation), the RNA input type (total RNA or enriched), the read configuration, the annotation sources and versions used for quantification, and the cleanup used to remove adapter dimers. The sources above show that each of these choices changes which RNAs are counted, so a reader cannot interpret relative abundance without them.

Common misunderstandings

Can an mRNA-seq kit be used for small RNA?

No. Illumina states that total RNA and mRNA library kits do not retain small RNA fragments through bead cleanup, so a dedicated small RNA kit is needed.

Is paired-end sequencing better?

Not for this method. The whole insert is captured in a single read, and Illumina says paired-end offers no advantage.

Does small RNA-seq count every small RNA equally?

No. Ligation bias and end chemistry mean relative read counts can reflect capture efficiency, not only abundance. The review states that sequencing-related bias such as lane and flow-cell effects is considered minor compared with ligation.

Is a hybridisation panel a sequencing alternative?

It answers a different question. Hybridisation platforms use predesigned probes, so they cannot discover novel miRNAs, and the review reports that nCounter showed low correlation with RNA-seq methods.

Does the method work at single-cell level?

Single-cell small RNA methods have been published, for example the Small-seq method published in Nature for single-cell small-RNA sequencing. For the mRNA counterpart, see single-cell RNA sequencing.

Sources

Data: Small RNA-seq library preparation approaches: capture principle, reported strengths and limitations

Compares four library preparation approaches for small RNA profiling (traditional two-adaptor ligation, randomised-adaptor ligation, ligation-free, hybridisation) using statements from a 2021 peer-reviewed review; compiled by CASRAI from that review only.

Small RNA-seq library preparation approaches: capture principle, reported strengths and limitations
ApproachHow the RNA is capturedReported strengthsReported limitations
Traditional two-adaptor ligationPre-adenylated 3' adaptor ligated first, then 5' adaptor, followed by reverse transcription and PCRWidely used formatLigation bias from miRNA and adaptor secondary structure; performed poorly across benchmarking studies
Improved ligation with randomised adaptorsAdaptors with randomised bases, or single-adaptor plus circularisation; some designs add UMIsDescribed as most robust overall; selected as a standard by the Extracellular RNA Communication ConsortiumRandomised bases used as UMIs risk over-deduplication of abundant miRNAs
Ligation-free (polyadenylation, template switching)RNA is polyadenylated or template-switched instead of ligatedAvoids ligation bias; polyadenylation more accurate than traditional ligationOften low miRNA mapping rates; lower yield and mapping rate than ligation methods
Hybridisation (nCounter, FirePlex, HTG EdgeSeq)Predesigned probes hybridise to target miRNAsHTG EdgeSeq showed strong accuracy, mapping rate and sensitivity in one studyPredesigned probes only; lower specificity for EdgeSeq in one study; nCounter showed low correlation with RNA-seq methods

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Small RNA Sequencing: Workflow, Library Prep and Bias

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →