Written and maintained by CASRAI Editorial Board
Published
On this page
Short answer
Soil liquefaction is a process in which saturated sandy or silty soil loses strength during earthquake shaking and, for a short time, behaves more like a fluid than a solid. The U.S. Geological Survey (USGS) stresses that it is a physical process, not a type of ground failure: the failures it can lead to are lateral spreads, flow failures and loss of bearing strength.
Definition and scope
The USGS describes liquefaction as a process that takes place during some earthquakes and that may lead to ground failure. Shaking causes water-saturated sand and silt to lose strength, and the ground can then move, settle or fail in ways that damage buildings, bridges, pipelines and port structures.
The 2021 National Academies of Sciences, Engineering, and Medicine (NASEM) consensus report on the state of the art and practice in assessing earthquake-induced soil liquefaction uses a broader engineering definition: the seismic generation of excess porewater pressures and the consequent softening of granular soils. In that framing, the term covers both the conditions at the onset of the phenomenon, called liquefaction triggering, and what the soil does once it has softened, including its effects on the strength, stability and deformation of the ground.
The scope of this page is the concept and how it is assessed. Remedial measures for increasing liquefaction resistance, and mitigation of post-liquefaction consequences, were explicitly outside the NASEM report and are not covered here either. For the wider discipline that houses this topic, see What Is Civil Engineering? and, for the soil itself, What Is Soil Science?
Which ground is susceptible?
The USGS states that liquefaction is restricted to certain geologic and hydrologic environments, mainly areas where sands and silts were deposited in the last 10,000 years and where ground water is within 30 feet of the surface. Looser, younger sediment and a higher water table make a site more vulnerable. This gives a first screening checklist, summarised below from the USGS wording.
- Soil type: sand and silt deposits (granular soil) are the materials the USGS names.
- Age: deposited within roughly the last 10,000 years; looser, younger sediment is more susceptible.
- Water: the soil is saturated, with ground water within about 30 feet (roughly 9 metres) of the surface.
- Shaking: an earthquake strong enough to disturb the soil. The NASEM report maps where the horizontal peak ground acceleration (PGA) specified by the International Building Code for residential and commercial construction is 0.1 g or greater, and notes that liquefaction cannot be precluded in the areas outside that shading, depending on site-specific conditions.
These are screening conditions, not a design calculation. Identifying which soils at a site are classified as sand, silt or clay is itself a laboratory task; see ASTM D2488 visual-manual soil identification and ASTM D6913 sieve analysis of soils for the standard test methods behind soil description and grain-size data.
How it works
NASEM summarises the mechanism in three linked steps. Earthquake shaking disturbs the structure (fabric) of a loose granular soil. In saturated soil the water cannot escape instantly, so the pressure in the pore water rises. As that excess porewater pressure builds, the grains carry less of the load and the soil loses much of its strength and stiffness. The USGS describes the result as saturated sand and silt acting like a fluid for a short time.
How liquefaction is assessed in practice
NASEM separates two questions that are often blurred together.
1. Triggering: will the soil soften?
The most common practical approach is the simplified stress-based procedure, first proposed in 1971 (often called the Seed-Idriss simplified procedure). It compares two quantities: the cyclic stress ratio (CSR), a measure of the loading the earthquake imposes, and the cyclic resistance ratio (CRR), a measure of the soil’s resistance. The factor of safety is the ratio of resistance to demand. CSR is estimated from peak ground acceleration and stress terms rather than a full site-response analysis, and is corrected with a magnitude scaling factor.
CRR is tied to an in situ measurement. The original method used the standard penetration test (SPT) blow count; later variants use other indices, namely cone penetration test (CPT) resistance and shear wave velocity. NASEM describes current practice as deterministic: factors of safety computed against depth for a chosen earthquake scenario. The report calls for movement toward probabilistic, performance-based analysis.
2. Consequences: what will the softened ground do?
Consequence assessment asks about settlement, lateral spreading, slope failure and damage to buildings, roads, dams and utilities. NASEM finds the methods for predicting consequences less mature and less validated than those for triggering. A reader should therefore treat a triggering result and a consequence estimate as results of different reliability.
Types of ground failure
The USGS identifies three ground failures caused by liquefaction, plus related effects such as settlement and sand boils.
- Lateral spreads: lateral movement of large blocks of soil in response to shaking. The USGS describes these as usually disruptive rather than catastrophic.
- Flow failures: liquefied soil, or blocks of intact material riding on a layer of liquefied soil. The USGS calls these the most catastrophic type of liquefaction-caused failure.
- Loss of bearing strength: the soil supporting a building or other structure liquefies and loses strength, so the structure can settle and tip.
The data table below pairs each failure type with the historical event the USGS uses to illustrate it, with the location, year and reported effect for each. Reading across it shows that the same physical process produced very different outcomes depending on slope, setting and structure.
Where it matters for labs, testing and engineering decisions
For geotechnical and earthquake engineering teams, the NASEM recommendations are the most practical guidance on how the field data behind a liquefaction assessment should be produced and used:
- Prefer the CPT for measuring field resistance, and if the SPT is used, measure the hammer energy.
- Apply simplified methods only as originally developed, and consider more than one published variant rather than one.
- Quantify the uncertainties. NASEM names the main ones as the stress reduction factor, the relation between CRR and SPT resistance, and the overburden and static shear corrections.
- Draw on curated, public case-history databases, and move toward performance-based probabilistic analysis.
NASEM also observes that triggering procedures developed after 1996 differ substantially at depths beyond about 15 to 18 metres and for fines contents above about 5 percent, which is a reminder that grain-size testing and depth both change the answer. Structural engineers who model buildings on soft ground use analysis packages such as the one described in SAP2000: Structural Analysis Software Explained; the soil behaviour that feeds such a model comes from the geotechnical assessment above.
Common misunderstandings
Liquefaction is not itself a ground failure
The USGS is explicit: liquefaction is a physical process. The visible damage is a lateral spread, flow failure or bearing-strength loss, or related settlement and sand boils.
Not every earthquake or every site liquefies
Susceptibility depends on geology and groundwater. A site with old, dense deposits or a deep water table does not meet the USGS conditions, while young, loose, saturated sands do.
Triggering analysis does not by itself predict damage
Finding that a layer will soften answers the triggering question only. How far the ground moves and what happens to structures is a consequence question, and NASEM rates those methods as less validated.
The soil does not stay liquid
The USGS describes the fluid-like behaviour as lasting for a short time during shaking. Damage can nevertheless be permanent: the 1964 Niigata apartment buildings tipped, and most were later jacked upright and reused.
Frequently asked questions
What soils can liquefy?
According to the USGS, saturated sands and silts, particularly those deposited in the last 10,000 years with ground water within 30 feet of the surface. Looser, younger sediment is more vulnerable.
What does liquefaction do to buildings and infrastructure?
It can cause lateral spreads, flow failures and loss of bearing strength. The USGS cites pipeline breaks in the 1906 San Francisco earthquake, more than 200 bridges damaged or destroyed in the 1964 Alaska earthquake, and tipped apartment buildings in Niigata in 1964.
How is liquefaction potential evaluated?
The most common method compares earthquake loading (CSR) with soil resistance (CRR) derived from SPT, CPT or shear wave velocity measurements, usually reported as a factor of safety against depth for a scenario earthquake.
Which field test does NASEM prefer?
The 2021 NASEM report recommends the CPT for field resistance and, where the SPT is used, measuring hammer energy.
Sources
- U.S. Geological Survey, What are the effects of earthquakes? (Earthquake Hazards Program), read 12 November 2026.
- National Academies of Sciences, Engineering, and Medicine (2021), State of the Art and Practice in the Assessment of Earthquake-Induced Soil Liquefaction and Its Consequences, National Academies Press, chapter 1 and summary, read 12 November 2026.
Data: Liquefaction-caused ground failure types and the historical earthquakes the USGS uses to illustrate them
Compiled from the U.S. Geological Survey Earthquake Hazards Program page on the effects of earthquakes: each row pairs one historical earthquake with the ground failure type the USGS associates with it and the reported effect.
Period covered: 1906/1964.
| Earthquake | Year | Location | Ground failure type | Reported effect |
|---|---|---|---|---|
| San Francisco earthquake | 1906 | San Francisco, California, USA | Lateral spread | Major pipeline breaks in the city; displacements of less than 7 feet largely responsible for the devastation |
| Kansu earthquake | 1920 | Kansu, China | Flow failure | Flow failures up to 1 mile in length and breadth; an estimated 200,000 deaths |
| Prince William Sound earthquake | 1964 | Alaska, USA | Lateral spread (also submarine flow failures) | More than 200 bridges damaged or destroyed; port facilities at Seward, Whittier and Valdez carried away by submarine flow failures |
| Niigata earthquake | 1964 | Niigata, Japan | Loss of bearing strength | Several four-story apartment buildings tipped as much as 60 degrees; most later jacked upright and reused |
Sources
- USGS: What are the effects of earthquakes? (accessed 2026-11-12)