Written and maintained by CASRAI Editorial Board
Published
On this page
Short answer
The Strep-tag is a synthetic peptide affinity tag engineered for single-step protein purification and detection under physiological conditions. The modern Strep-tag II consists of an eight-amino-acid sequence (WSHPQFEK, 1.06 kDa) that binds the engineered streptavidin matrix Strep-Tactin with micromolar affinity. Target proteins elute gently using 2.5 mM desthiobiotin, preserving native folding, enzyme activity, and fragile multi-subunit complexes.
Definition and scope
In recombinant protein biochemistry, the strep tag refers to a class of short peptide affinity tags developed to enable rapid, high-purity isolation of functional proteins directly from crude biological extracts. Established by Thomas G. M. Schmidt and Arne Skerra, the system avoids extreme pH, chaotropic denaturants, and metal-stripping agents that destabilize target proteins.
Unlike bulky fusion partners such as GST (26 kDa) or MBP (42 kDa), the modern Strep-tag II is an eight-residue peptide (1,058 Da). Its minimal steric size, neutral net charge at physiological pH, and lack of hydrophobic patches render it biologically inert. It can be fused to the N-terminus, C-terminus, or surface loops of recombinant proteins without perturbing tertiary folding or membrane translocation. Expression constructs are distributed through repositories like the Addgene plasmid repository and commercial vectors. Beyond preparative chromatography, Strep-tag fusions serve in sandwich ELISA assay formats, western blotting, and surface plasmon resonance (SPR).
How it works or how it is used in practice
Affinity chromatography with Strep-tag fusion proteins relies on a reversible competitive binding mechanism. Natural streptavidin binds free biotin with femtomolar affinity (Kd approximately 10^-14 M), requiring harsh denaturants to break. Researchers engineered Strep-Tactin, a modified streptavidin tetramer with binding-pocket mutations conferring reversible micromolar affinity (Kd approximately 1 µM) toward Strep-tag II.
Standard bench purification follows five distinct phases:
1. Sample Clarification
Expressing cells are lysed under non-denaturing conditions. Insoluble particulates and debris must be eliminated by high-speed centrifugation (15,000 × g to 40,000 × g, 20–30 min at 4°C) followed by syringe filtration through a 0.22 µm or 0.45 µm membrane filter before loading (Sigma-Aldrich, Cytiva).
2. Column Equilibration
Columns—whether gravity-flow, spin columns, or automated ÄKTA chromatography systems—are equilibrated with 5 to 10 column volumes (CV) of Buffer W (100 mM Tris-HCl, pH 8.0, 150 mM NaCl, 1 mM EDTA; see our guide on Tris-HCl buffer and general buffer solutions). For metalloproteins requiring Mg²⁺ or Ca²⁺, EDTA is omitted or replaced with PBS (pH 7.4).
3. Loading and Washing
Clarified lysate is applied at 0.5 to 1 ml/min. Strep-tag II binds the Strep-Tactin matrix while untagged host contaminants flow through. The matrix is washed with 5 to 10 CV of Buffer W until A280 absorbance returns to baseline.
4. Competitive Elution
Target protein is eluted with Buffer E (Buffer W containing 2.5 mM D-desthiobiotin). Desthiobiotin competitively displaces Strep-tag II at neutral pH, eluting active protein without altering salt concentration or temperature.
5. Column Regeneration
Strep-Tactin resin is regenerated for 3 to 5 reuse cycles using 3 CV of 100 mM NaOH or 1 mM HABA in Buffer W. HABA binds Strep-Tactin and turns the resin orange-red, visually confirming desthiobiotin displacement. The column is re-equilibrated with 15 CV of Buffer W until neutral pH is restored and the color clears.
Types or related concepts
The table below summarizes key parameters of Strep-tag variants and common affinity tags based on manufacturer and literature data:
| Tag System | Sequence & Size | Matrix | Kd | Elution Mechanism | Primary Advantage |
|---|---|---|---|---|---|
| Strep-tag II | WSHPQFEK (8 aa, 1.06 kDa) | Strep-Tactin | ~1 µM | 2.5 mM desthiobiotin (pH 8.0) | >95% single-step purity; physiological elution |
| Twin-Strep-tag | Tandem WSHPQFEK (~28 aa, 2.8 kDa) | Strep-Tactin XT | ~300 pM | 50 mM biotin (Buffer BXT) | Picomolar capture; tolerates 0.1% SDS and 1 M NaCl |
| Polyhistidine (6xHis) | HHHHHH (6 aa, 0.84 kDa) | Ni-NTA / TALON | 1–10 µM | 250–500 mM imidazole or pH 4.5 | Inexpensive resin; works under 8 M urea |
| FLAG-tag | DYKDDDDK (8 aa, 1.01 kDa) | Anti-FLAG M2 resin | 10–100 nM | 3xFLAG peptide or pH 3.5 | High specificity; enterokinase cleavage |
Strep-tag II (strepii tag) peptide sequence and design
The Strep-tag II peptide sequence is Trp-Ser-His-Pro-Gln-Phe-Glu-Lys (WSHPQFEK). Inserting a short flexible linker (such as Gly-Gly-Gly-Ser) between the tag and protein prevents steric hindrance. To improve yield from dilute culture supernatants, the Twin-Strep-tag pairs two Strep-tag II motifs with an internal linker (WSHPQFEK-GGGSGGGSGG-SA-WSHPQFEK). This tandem arrangement generates bivalent avidity on Strep-Tactin XT matrices, driving dissociation constants down to picomolar levels without sacrificing mild elution.
Where it matters for labs, clinics or supply decisions
Selecting an affinity platform impacts product integrity, operational reliability, and consumable budgets:
1. Complex Assembly and Metalloprotein Integrity
Unlike IMAC systems where 250–500 mM imidazole strips structural metal cofactors (such as Zn²⁺ or Mg²⁺) or disrupts delicate subunit associations, Strep-tag elution occurs at physiological pH 8.0 and 150 mM NaCl. This preserves multi-subunit protein assemblies and enzymatic activity without precipitation.
2. Biotin Masking in Culture Supernatants
Free D-biotin in culture media binds Strep-Tactin irreversibly under native conditions, blocking resin binding sites. Mammalian media (DMEM, RPMI-1640) and insect media contain 0.1 to 1 mg/L free biotin. Adding 2 to 3 µg avidin or commercial masking solution (bioLock) per milliliter of supernatant complexes free biotin prior to loading, preventing column fouling without reducing Strep-tag binding.
3. Consumable Lifecycle and Economics
While Strep-Tactin resin has a higher initial cost per milliliter than Ni-NTA, it delivers >95% purity in a single step, bypassing secondary polishing columns. Reusing resins for 3 to 5 cycles via NaOH or HABA regeneration and omitting post-purification protease cleavage substantially lowers total processing costs.
Common misunderstandings
- “Strep-tag binds wild-type streptavidin effectively”: Wild-type streptavidin exhibits poor affinity toward Strep-tag II. Strep-tag II requires the engineered binding pocket of Strep-Tactin to achieve micromolar affinity at N-terminal, C-terminal, or internal positions.
- “Strep-tag must always be cleaved off”: Because Strep-tag II is only 8 amino acids (1.06 kDa) with a balanced charge, it rarely interferes with crystallization or assays. Proteolytic removal is optional.
- “Strep-Tactin columns can be eluted with imidazole”: Imidazole does not bind Strep-Tactin. Elution strictly requires competitive displacement with D-desthiobiotin (or biotin for Strep-Tactin XT).
- “Free biotin in media does not affect purification”: Free biotin competitively poisons Strep-Tactin columns. Unmasked mammalian or insect cell media causes complete target loss into the flow-through.
- “Strep-tag works under 8 M urea”: Strep-Tactin binding requires intact tertiary protein structure. High concentrations of urea or guanidine-HCl denature the matrix; denaturing purifications require His-tags.
Frequently asked questions
What is the difference between Strep-tag and Strep-tag II?
The original Strep-tag (AWRHPQFGG, 9 aa) bound wild-type streptavidin only at the extreme C-terminus. Strep-tag II (WSHPQFEK, 8 aa) was engineered to bind Strep-Tactin at N-terminal, C-terminal, or internal locations.
What is the amino acid sequence of Strep-tag II?
The amino acid sequence is Trp-Ser-His-Pro-Gln-Phe-Glu-Lys, abbreviated as WSHPQFEK, with a molecular mass of ~1,058 Da.
How is a Strep-tagged protein eluted?
Proteins are eluted at physiological pH 8.0 by adding 2.5 mM D-desthiobiotin to the wash buffer, competitively displacing the tag without denaturing conditions.
Can Strep-tag be used for western blotting and biosensors?
Yes. Fusions can be detected using enzyme-conjugated Strep-Tactin or StrepMAB-Classic antibody, and immobilized on SPR sensor chips using StrepMAB-Immo.
How do you regenerate a Strep-Tactin column?
Wash the column with 3 CV of 100 mM NaOH or 1 mM HABA in Buffer W. HABA turns the matrix orange-red, verifying desthiobiotin displacement, followed by 15 CV of Buffer W to restore neutral pH.
Sources
- Schmidt, T. G. M., & Skerra, A. (2007). “The Strep-tag system for one-step purification and high-affinity detection or capturing of proteins.” Nature Protocols, 2(6), 1528–1535. PMID: 17571060. DOI: 10.1038/nprot.2007.209 (read 2026-11-10).
- IBA Lifesciences. “The Strep-tag® System: General Information and Protocols for Strep-tag®II and Twin-Strep-tag® Protein Purification.” Manual / Technical Guide, IBA Lifesciences GmbH, Göttingen, Germany. URL: https://www.iba-lifesciences.com/download-area.html (read 2026-11-10).
- Sigma-Aldrich / Merck KGaA. “Strep-tag® II Purification Protocol.” Technical Documents, Protein Biology & Purification. URL: https://www.sigmaaldrich.com/technical-documents/protocol/protein-biology/protein-purification/strep-tag-purification-protocol (read 2026-11-10).
- Cytiva Life Sciences. “StrepTrap HP Instructions.” Document 28-9136-34 AB, Cytiva / GE Healthcare Bio-Sciences AB, Uppsala, Sweden. URL: https://www.cytivalifesciences.com (read 2026-11-10).







