Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
A sucrose safety data sheet (SDS) documents the chemical identity, physical hazards, occupational exposure limits, and handling protocols for D-sucrose (CAS 57-50-1). While regulatory bodies including OSHA, the European Chemicals Agency (ECHA), and major chemical suppliers classify sucrose as a non-hazardous substance under standard laboratory conditions, finely divided airborne sucrose dust presents a recognized combustible dust explosion hazard, and bulk aqueous solutions require specific handling to prevent microbial contamination and environmental loading.
Definition, Chemical Properties, and CAS Number
Sucrose (chemical formula C12H22O11, molecular weight 342.30 g/mol, CAS number 57-50-1) is a non-reducing disaccharide composed of glucose and fructose linked by an α-1,2-glycosidic bond. In scientific literature and safety documentation, it is also designated as D-(+)-sucrose, saccharose, cane sugar, beet sugar, and α-D-glucopyranosyl-(1→2)-β-D-fructofuranoside. It is indexed under EC number 200-334-9 and RTECS number WN6500000.
In physical appearance, laboratory-grade sucrose is an odorless, white crystalline solid or fine white powder with a characteristic sweet taste. Its physical and chemical parameters relevant to laboratory operations and industrial safety include:
- Melting point and decomposition: Sucrose melts between 160 °C and 186 °C (320 °F to 367 °F) with simultaneous thermal decomposition, precluding a true atmospheric boiling point. At temperatures exceeding 160 °C, caramelization occurs, producing volatile decomposition products and water vapor.
- Solubility: Sucrose is exceptionally soluble in water, dissolving at approximately 2,000 g/L (or roughly 67% w/w) at 20 °C, and increasing to over 4,000 g/L at 80 °C. It is sparingly soluble in ethanol and virtually insoluble in non-polar organic solvents like diethyl ether, chloroform, and hexane.
- Specific rotation: In polarimetry, aqueous D-sucrose exhibits an optical rotation [α]D²⁰ of +66.3° to +66.8° (c = 26 in water), an essential quality assurance metric for reagent purity.
- Bulk density: The loose bulk density of crystalline sucrose ranges from 800 to 950 kg/m³, whereas finely ground powdered sucrose displays bulk densities between 500 and 700 kg/m³, which directly influences dust suspension dynamics in air.
- Solution pH: Neutral aqueous solutions (10% to 50% w/v) typically display a pH between 5.5 and 7.5 when prepared in high-purity deionized water.
GHS Classification and Hazard Identification Across Regulatory Bodies
Under the Globally Harmonized System of Classification and Labelling of Chemicals (GHS), as implemented by the United States Occupational Safety and Health Administration (OSHA Hazard Communication Standard, 29 CFR 1910.1200) and the European Union CLP Regulation (EC No 1272/2008), sucrose is not classified as a health hazard. It does not meet criteria for acute toxicity, skin corrosion, serious eye damage, respiratory sensitization, germ cell mutagenicity, carcinogenicity, or reproductive toxicity.
In the ECHA Classification and Labelling (C/L) Inventory maintained under REACH regulations, over 95% of notifying chemical manufacturers classify sucrose as “Not Classified” for health and environmental endpoints. A small fraction of notifications report mild mechanical eye irritation resulting from physical crystalline abrasion.
However, regulatory authorities and manufacturer safety data sheets enforce a critical physical hazard distinction based on particulate state:
- OSHA Combustible Dust Classification: In the United States, OSHA 29 CFR 1910.1200 Appendix B and Appendix C designate airborne organic dust clouds capable of igniting and producing deflagrations as hazardous. Because finely divided dry sucrose particles suspended in air can form an explosive mixture, OSHA-aligned SDSs assign the signal word Warning and the hazard statement May form combustible dust concentrations in air.
- European CLP Classification: Under EU CLP regulations, combustible dust is not a standardized standalone hazard class with dedicated GHS pictograms, although EU SDS Section 2 documents dust explosion hazards under supplementary information.
- NFPA 704 Standard Rating: Under the National Fire Protection Association hazard identification system, sucrose carries ratings of Health 0 (minimal hazard), Flammability 0 or 1 (bulk crystalline sugar is difficult to ignite, but fine dust presents a combustion hazard), and Instability/Reactivity 0 (stable under ordinary conditions).
Sourced Comparison of Supplier Safety Data Sheets
Although sucrose has a single chemical CAS identity (57-50-1), safety data sheets provided by major laboratory suppliers display subtle differences in hazard wording, grade-specific purity guarantees, and recommended controls. When establishing standard operating procedures under a laboratory safety chemical hygiene plan, cross-referencing these sheets clarifies institutional expectations.
A review of safety data sheets from leading global suppliers reveals several distinct reporting conventions:
- MilliporeSigma / Sigma-Aldrich (Product S0389, Molecular Biology Grade): Sigma-Aldrich designates sucrose as a Combustible Dust under US OSHA HCS 2012, assigning the signal word “Warning” and the hazard statement “May form combustible dust concentrations in air.” The sheet notes that sucrose is certified free of detectable DNase, RNase, and protease activity. Recommended PPE includes safety glasses with side-shields conforming to EN 166 or ANSI Z87.1, protective nitrile gloves with a minimum thickness of 0.11 mm providing breakthrough times exceeding 480 minutes, and standard laboratory coats. Sigma classifies its storage class under German TRGS 510 as LGK 10-13.
- Fisher Scientific (Catalog BP220, Fisher BioReagents; S5-500, Certified ACS): Fisher Scientific classifies both its ACS crystalline grade and BioReagents molecular biology grade as non-hazardous under OSHA 29 CFR 1910.1200 and GHS Rev 8. Unlike Sigma, Fisher does not assign a formal signal word on its primary Section 2 banner, but notes under Section 5 (Firefighting Measures) and Section 7 (Handling and Storage) that fine organic dusts can present a particulate flash hazard if suspended in confined spaces with an ignition source.
- Carl Roth GmbH + Co. KG (Article 4621, D(+)-Saccharose, p.a. / Ph. Eur.): Carl Roth’s European SDS complies with EC Regulation 1907/2006 (REACH) and EC 1272/2008 (CLP). The product carries no hazard pictograms, no signal word, and no hazard statements. Purity is guaranteed at ≥ 99.5% with strict limits on heavy metals (≤ 0.0005%) and sulfated ash (≤ 0.02%). The sheet assigns storage class LGK 10-13, emphasizing basic hygiene: avoiding dust formation and maintaining dry storage.
- Avantor / VWR Chemicals BDH (Catalog BDH0308, ACS Reagent): Avantor classifies the substance as non-hazardous under standard operating conditions. Section 7 emphasizes minimizing mechanical impact and static discharge during bulk powder transfer. Recommended PPE includes splash goggles or safety glasses, nitrile or neoprene gloves, and general exhaust ventilation.
For an overview of how individual manufacturers structure the standard 16-section document format, consult our comprehensive reference on how to read a safety data sheet. The data table below compares the specific regulatory designations, exposure thresholds, and safety parameters across these suppliers and regulatory standards.
Occupational Exposure Limits and Industrial Hygiene Standards
Because sucrose exhibits extremely low systemic toxicity, occupational exposure limits are established to protect workers against chronic respiratory irritation and mechanical pulmonary loading caused by inert particulates. In industrial hygiene, sucrose is evaluated under the general category of “particulates not otherwise regulated” (PNOR) or “nuisance dusts.”
Key regulatory and consensus exposure limits enforced in the United States and internationally include:
- OSHA Permissible Exposure Limit (PEL): Enforced under 29 CFR 1910.1000 Table Z-1, the mandatory 8-hour time-weighted average (TWA) for sucrose dust is 15 mg/m³ for total dust and 5 mg/m³ for the respirable fraction. Employers are legally required to maintain laboratory and manufacturing air concentrations below these limits.
- NIOSH Recommended Exposure Limit (REL): The National Institute for Occupational Safety and Health recommends a 10-hour TWA of 10 mg/m³ for total airborne dust and 5 mg/m³ for respirable dust (RTECS WN6500000). NIOSH has not established an Immediately Dangerous to Life or Health (IDLH) concentration due to the absence of acute systemic lethality.
- ACGIH Threshold Limit Value (TLV): The American Conference of Governmental Industrial Hygienists recommends an 8-hour TWA of 10 mg/m³ for inhalable particulate matter. The ACGIH assigns sucrose a Carcinogenicity classification of A4 (“Not classifiable as a human carcinogen”), confirming that epidemiological studies and animal bioassays show no evidence of carcinogenic potential.
- United Kingdom Workplace Exposure Limit (WEL): Under the UK Health and Safety Executive (HSE EH40/2005), the long-term exposure limit (8-hour TWA) for sucrose is 10 mg/m³, with a short-term exposure limit (STEL, 15-minute reference period) of 20 mg/m³.
Toxicological studies compiled in chemical registries demonstrate that sucrose possesses an oral lethal dose 50% (LD50) in rats of greater than 29,700 mg/kg. Inhalation acute toxicity is likewise negligible, with minor coughing and mucus membrane drying being the only observable physiological reactions to excessive acute particulate exposure. Comparing these thresholds to other common laboratory salts, such as those detailed in our calcium carbonate SDS and sodium carbonate SDS guides, illustrates how non-hazardous carbohydrates are regulated primarily through particulate mass rather than chemical toxicity.
Laboratory PPE, Engineering Controls, and Handling Protocols
Standard laboratory safety protocols must be observed when handling solid sucrose reagents or preparing concentrated stock solutions. Even though sucrose does not present an acute chemical hazard, adherence to standard operating procedures prevents reagent contamination, personal discomfort, and ergonomic strain.
Environmental health and safety (EHS) programs recommend the following tiered controls:
- Engineering controls: Routine bench weighing of milligram to gram quantities does not require specialized containment. However, when handling bulk containers (e.g., 5 kg to 25 kg containers) or transferring dry powders that generate visible dust clouds, operations should be performed inside a certified chemical fume hood, local exhaust canopy, or dedicated powder containment enclosure. General room ventilation with 6 to 12 air changes per hour is standard in academic and industrial laboratories.
- Eye and face protection: Standard ANSI Z87.1-approved safety glasses with side-shields or European EN 166 safety spectacles are required in all laboratory spaces. When preparing large volumes of boiling or hot concentrated sucrose syrups (which exhibit elevated boiling points and high thermal heat capacity), chemical splash goggles are recommended to protect against skin burns from accidental splashes.
- Skin and hand protection: Disposable nitrile examination gloves (minimum nominal thickness 0.10 to 0.12 mm) provide adequate barrier protection against mechanical contact and ensure that hand sweat and skin enzymes (such as invertase) do not contaminate biological preparations. Standard knee-length chemical-resistant laboratory coats and closed-toe footwear are mandatory.
- Respiratory protection: In standard bench workflows, respiratory protection is unnecessary. In bulk preparation rooms where air monitoring indicates dust concentrations exceeding 5 mg/m³ respirable or 10 mg/m³ total dust, personnel should wear a NIOSH-approved N95 particulate filtering facepiece respirator, governed by an institutional respiratory protection program conforming to 29 CFR 1910.134.
- Personal hygiene: Personnel must wash their hands thoroughly with soap and warm water after handling chemical reagents and before leaving laboratory zones. Eating, drinking, storing food, or applying cosmetics in chemical laboratory areas is strictly prohibited under OSHA regulations, regardless of the non-hazardous nature of the specific chemical being handled.
Modern institutions often track chemical inventory, standard operating procedures, and safety compliance across labs using specialized chemical safety software, which ensures that safety data sheets remain accessible on digital dashboards for all registered research staff.
Solution Preparation, Autoclaving, and Biological Media Stability
In life science laboratories, sucrose is ubiquitous in biological buffers, gradient centrifugation, and cell biology workflows. However, aqueous sucrose solutions introduce specific handling considerations that are not fully captured on standard industrial safety data sheets.
Common laboratory workflows and stability guidelines include:
- Density gradient centrifugation: High-density sucrose solutions (20% to 66% w/v) are widely utilized in swinging-bucket ultracentrifugation for isolating subcellular organelles, viral particles, membrane vesicles, and macromolecules. Preparing 50% to 60% w/v sucrose solutions requires slow addition of solid powder to warm buffer (40 °C to 50 °C) under vigorous magnetic stirring, as dissolution is endothermic. High-density solutions are extremely viscous (dynamic viscosity of 60% w/w sucrose at 20 °C is approximately 58 mPa·s, compared to 1.0 mPa·s for pure water), requiring care when pipetting to avoid splashing and volume inaccuracies.
- Tissue cryoprotection and electrophysiology: In histology and neuroscience, sucrose solutions (typically 15% to 30% w/v in phosphate buffer) serve as cryoprotectants to prevent ice crystal formation during tissue freezing. In slice physiology, sucrose-based cutting artificial cerebrospinal fluid (aCSF) replaces sodium chloride with 180 to 220 mM sucrose to prevent excitotoxic neuronal death during vibratome sectioning.
- Autoclaving vs. sterile filtration: A frequent operational question in biological labs is whether sucrose solutions can be sterilized by autoclaving. Autoclaving sucrose solutions at standard conditions (121 °C, 15 psi for 20 to 30 minutes) frequently causes hydrolysis (inversion) of sucrose into glucose and fructose, particularly if the solution pH is slightly acidic (pH below 6.5). Prolonged heat exposure causes caramelization and Maillard-type browning reactions, yielding toxic furfural derivatives that inhibit cell growth and alter gradient density. Therefore, the recommended sterilization method for molecular biology and tissue culture grade sucrose solutions is positive-pressure sterile filtration through a 0.22 μm polyethersulfone (PES) or cellulose acetate membrane. When autoclaving cannot be avoided (e.g., for microbiological agar media), sucrose solutions should be autoclaved separately at neutral pH for the minimum validated duration (e.g., 115 °C to 118 °C for 10 to 15 minutes) or prepared as concentrated sterile-filtered stock and added to autoclaved basal media after cooling to 50 °C.
- Microbiological contamination: Unpreserved aqueous sucrose solutions are rich nutrient substrates for airborne bacteria, yeasts, and molds. A 10% to 50% sucrose solution stored at room temperature without preservatives will develop visible bacterial turbidity and fungal mycelia within several days. Sterile stocks should be aliquoted under laminar flow and stored at 4 °C for short-term use (up to one month) or frozen at -20 °C for extended storage. For non-biological industrial or cleaning solutions, the addition of 0.02% sodium azide (NaN3) prevents microbial proliferation, but introduces significant chemical toxicity requiring dedicated hazardous waste disposal.
Storage Classes, Incompatibilities, and Combustible Dust Prevention
While sucrose is chemically inert under ambient conditions, safety data sheets identify clear storage requirements and chemical incompatibilities that must be respected in laboratory stockrooms and chemical storage cabinets.
Primary storage conditions and incompatibilities include:
- Storage environment: Store solid sucrose in original, tightly sealed containers in a cool, dry, and well-ventilated location away from direct sunlight and sources of ignition. Sucrose is hygroscopic; excessive atmospheric humidity causes caking and clumping, which impairs accurate gravimetric dispensing and encourages surface fungal growth. Under the German chemical storage code TRGS 510, sucrose falls into storage class LGK 10-13 (non-combustible and combustible solids without special hazards), meaning it can be co-stored with other standard non-reactive solids.
- Chemical incompatibilities: Sucrose is a polyhydroxy compound that reacts vigorously with strong oxidizing agents. Contact with concentrated nitric acid (HNO3) or potassium permanganate (KMnO4) can cause violent oxidation, release of toxic nitrogen dioxide gas, and thermal runaway. Contact with concentrated sulfuric acid (H2SO4) results in a rapid and dramatic dehydration reaction: sulfuric acid strips water molecules from the carbohydrate backbone, leaving an expanding column of porous elemental carbon (the classic “carbon sugar snake”) accompanied by steam and choking sulfur dioxide (SO2) fumes. Sucrose must never be stored in direct contact with strong mineral acids, liquid oxidizers, or halogenating reagents.
- Combustible dust deflagration dynamics: In industrial facilities, milling units, or bulk handling suites, finely powdered sucrose presents an explosion hazard if three conditions coincide: a dispersed dust cloud with particle diameters below 420 μm, an airborne concentration exceeding the lower explosive limit (LEL, approximately 45 g/m³ for sucrose), and an ignition source exceeding the minimum ignition energy (MIE, typically between 30 and 100 mJ). The minimum autoignition temperature for a sucrose dust cloud is approximately 350 °C to 380 °C. In benchtop research laboratories, quantities rarely reach the lower explosive limit, but researchers grinding sucrose in mechanical ball mills or using dry spray-drying apparatus must ensure equipment is grounded, static electricity is eliminated, and dust accumulation on elevated ledges is prevented.
Spill Cleanup, Drain Disposal, and EHS Waste Compliance
Spill management and disposal of laboratory chemicals must comply with institutional environmental health and safety policies and regional municipal sewer ordinances. Sucrose handling generates both solid powder spills and viscous liquid syrup releases, each requiring distinct mitigation approaches.
Recommended spill cleanup procedures:
- Solid powder spills: Avoid dry sweeping or compressed air blowing, which aerosolizes fine particulates and creates airborne dust clouds. For small benchtop spills (less than 500 g), carefully scoop or scrape the material into a clean container for disposal. Alternatively, wipe the surface with damp paper towels or use a HEPA-filtered vacuum cleaner certified for combustible organic dusts. Wash the residual area with warm water to prevent sticky residue.
- Liquid syrup spills: Concentrated sucrose solutions (such as density gradient fractions or cell culture stocks) dry into hard, sticky residues that can foul laboratory equipment, attract pests, and create slipping hazards on floors. Absorb liquid spills promptly using universal absorbent pads, vermiculite, or dry paper wipes. Clean the contaminated floor or benchtop with a standard laboratory detergent and warm water, followed by an alcohol wipe (70% ethanol or isopropanol) to sanitize the surface.
Waste disposal and environmental regulatory classification:
- RCRA Hazardous Waste Status: Under the United States Resource Conservation and Recovery Act (40 CFR Part 261), pure sucrose is not listed as a hazardous waste (neither P-listed, U-listed, nor characteristic for toxicity, corrosivity, reactivity, or ignitability). Solid waste contaminated only with sucrose can generally be discarded in regular municipal solid trash, unless it has come into contact with regulated biohazardous agents or toxic chemical reagents.
- Drain disposal and Biochemical Oxygen Demand (BOD): While dilute aqueous sucrose solutions are non-toxic to aquatic organisms and readily biodegradable, municipal publicly owned treatment works (POTWs) strictly regulate the discharge of concentrated biodegradable organics. Dissolved sucrose creates high biochemical oxygen demand (BOD) and chemical oxygen demand (COD), which can deplete dissolved oxygen in biological wastewater treatment systems or local waterways. Bench-scale rinses and dilute fractions (under 5% w/v) may generally be discharged down the sanitary sewer with copiously running tap water, subject to local wastewater permits. In contrast, bulk concentrated stocks (e.g., several liters of 50% to 60% sucrose syrups) should not be dumped down the drain in single slugs; they must be diluted appropriately or collected through institutional chemical waste channels for regulated biological waste management.
Common Misunderstandings About Sucrose Safety in Research Laboratories
Because sucrose is universally recognized as a household food ingredient, laboratory personnel frequently adopt casual handling practices that can compromise experimental rigor or violate institutional safety compliance. Environmental health and safety officers routinely encounter several persistent misconceptions:
- Misunderstanding 1: “Food-grade grocery store sugar can be substituted for laboratory-grade sucrose.” Grocery store granulated sugar is formulated for human consumption, not quantitative research. Commercial table sugar contains minor anti-caking agents, trace sulfur dioxide from bleaching, mineral ash, and variable moisture content that do not interfere with cooking, but can ruin molecular biology assays, alter enzyme kinetics, or introduce endotoxin and nuclease contamination into cell cultures. Research applications require designated reagent-grade, ACS-certified, or molecular biology-grade sucrose with documented lot-specific certificates of analysis.
- Misunderstanding 2: “Because sucrose is non-toxic, it can be consumed in the laboratory.” Under OSHA 29 CFR 1910.1450 (Occupational Exposure to Hazardous Chemicals in Laboratories), consuming food or beverages in any designated chemical or biological laboratory space is a severe regulatory violation. Even if a container contains pure sucrose, storing or tasting laboratory reagents risks catastrophic cross-contamination with toxic, mutagenic, or radioactive agents handled in adjacent workspace zones. Reagent containers must never be treated as edible.
- Misunderstanding 3: “Autoclaving is always the preferred method to sterilize sucrose buffers.” As detailed in earlier sections, high-temperature thermal sterilization hydrolyzes sucrose into glucose and fructose and induces caramelization, producing inhibitory byproducts that degrade experimental reproducibility. Unless a specific microbiological formulation explicitly demands autoclaving, sterile filtration through a 0.22 μm membrane is the standard life science practice.
- Misunderstanding 4: “Sucrose dust is completely harmless because sugar does not explode.” While crystalline granulated sugar in a beaker does not pose an explosion risk, finely pulverized sugar dust is a notorious historical cause of catastrophic industrial dust explosions (such as the 2008 Imperial Sugar refinery disaster). In research labs performing mechanical ball-milling, spray-drying, or pilot-scale feed hoppers, combustible dust risk assessments and anti-static precautions are mandatory.
Frequently asked questions
What is the GHS classification for sucrose on a safety data sheet?
Under both OSHA Hazard Communication Standard (29 CFR 1910.1200) and European CLP regulations (EC 1272/2008), sucrose is not classified as a health or environmental hazard. However, US OSHA safety data sheets frequently classify dry sucrose powder as a Combustible Dust, carrying the signal word Warning and the hazard statement “May form combustible dust concentrations in air.”
What personal protective equipment is required when handling sucrose in the lab?
Standard laboratory personal protective equipment (PPE) for sucrose includes ANSI Z87.1-approved safety glasses with side-shields, disposable nitrile gloves (minimum 0.10 mm thickness), a standard chemical-resistant laboratory coat, and closed-toe footwear. When working with hot concentrated syrups or operations generating heavy airborne dust, chemical splash goggles or an N95 particulate respirator should be worn.
What are the occupational exposure limits for sucrose dust?
The OSHA Permissible Exposure Limit (PEL) for sucrose is 15 mg/m³ for total dust and 5 mg/m³ for the respirable dust fraction as an 8-hour time-weighted average (TWA). The NIOSH Recommended Exposure Limit (REL) is 10 mg/m³ total dust and 5 mg/m³ respirable dust (10-hour TWA), while the ACGIH Threshold Limit Value (TLV) is 10 mg/m³ (8-hour TWA).
Can concentrated sucrose solutions be poured down the laboratory sink?
Dilute sucrose rinses and small volumes (under 1 liter of dilute solution) can generally be discharged to the sanitary sewer accompanied by copious tap water, provided local municipal wastewater regulations allow. However, large volumes of concentrated syrups (20% to 60% w/v) exert a high Biochemical Oxygen Demand (BOD) on municipal sewage systems and should be collected for institutional disposal or diluted according to local environmental health and safety guidelines.
Why should high-concentration sucrose solutions be sterile-filtered rather than autoclaved?
Autoclaving aqueous sucrose solutions at standard sterilization conditions (121 °C for 20 to 30 minutes) induces thermal hydrolysis of the disaccharide into glucose and fructose, particularly in non-alkaline buffers. Prolonged thermal exposure causes caramelization and produces toxic furfural derivatives that interfere with cell growth and alter physical solution density. Sterile filtration through a 0.22 μm membrane avoids heat degradation and preserves solution integrity.
What chemicals are incompatible with sucrose in laboratory storage?
Sucrose is chemically incompatible with strong oxidizing agents (such as potassium permanganate, chlorates, and perchlorates) and concentrated mineral acids. Mixing sucrose with concentrated sulfuric acid triggers a violent exothermic dehydration reaction producing elemental carbon, steam, and toxic sulfur dioxide gas, while contact with concentrated nitric acid produces hazardous oxidation reactions and nitrogen dioxide emissions.
Sources
- Occupational Safety and Health Administration (OSHA). “Chemical Database: Sucrose (Chemical ID 589, CAS 57-50-1).” United States Department of Labor. Accessed 2026-11-14. https://www.osha.gov/chemicaldata/589
- National Center for Biotechnology Information (NCBI). “PubChem Compound Summary for CID 5988, Sucrose.” National Library of Medicine. Accessed 2026-11-14. https://pubchem.ncbi.nlm.nih.gov/compound/5988
- MilliporeSigma / Sigma-Aldrich. “Safety Data Sheet: Sucrose, Molecular Biology Grade (Product S0389, CAS 57-50-1).” Merck KGaA. Accessed 2026-11-14. https://www.sigmaaldrich.com
- Fisher Scientific. “Safety Data Sheet: D-Sucrose (Catalog Numbers BP220, S5-500, CAS 57-50-1).” Thermo Fisher Scientific. Accessed 2026-11-14. https://www.fishersci.com
- Carl Roth GmbH + Co. KG. “Safety Data Sheet: D(+)-Saccharose (Article Number 4621, EC 200-334-9, CAS 57-50-1).” Accessed 2026-11-14. https://www.carlroth.com
- Avantor Performance Materials. “Safety Data Sheet: Sucrose, ACS Reagent (Catalog Number BDH0308, CAS 57-50-1).” VWR Chemicals BDH. Accessed 2026-11-14. https://www.avantorsciences.com
Data: Sucrose Laboratory Safety and Regulatory Comparison
Comparative analysis of safety data sheet parameters, GHS hazard classifications, combustible dust designations, exposure limits, and storage classifications across major laboratory chemical suppliers and regulatory authorities.
| Supplier or Regulatory Authority | GHS Health Classification | Combustible Dust Designation | Assigned Signal Word | Total Dust Exposure Limit (mg/m³) | Respirable Exposure Limit (mg/m³) | Storage Class or Code |
|---|---|---|---|---|---|---|
| OSHA (29 CFR 1910.1000/1200) | Not classified as health hazard | Classified as Combustible Dust | Warning | 15 | 5 | General chemical storage |
| NIOSH (Pocket Guide / REL) | Not classified as toxic agent | Recognized organic dust explosion hazard | None | 10 | 5 | General industrial storage |
| ACGIH (Threshold Limit Values) | A4 - Not classifiable human carcinogen | Particulate matter inhalable fraction | None | 10 | 3 | Standard chemical warehouse |
| MilliporeSigma (Product S0389) | Not classified as health hazard | Combustible Dust (OSHA HCS 2012) | Warning | 15 | 5 | TRGS 510: LGK 10-13 |
| Fisher Scientific (Catalog BP220) | Not classified as hazardous | Explosive dust-air mixture warning in Sec 5/7 | None | 15 | 5 | Cool, dry chemical store |
| Carl Roth (Article 4621) | Not classified (EC 1272/2008 CLP) | Supplemental physical dust hazard advisory | None | 10 | 4 | TRGS 510: LGK 10-13 |
| Avantor / VWR (Catalog BDH0308) | Not classified as hazardous | Organic particulate explosion warning | None | 15 | 5 | General dry chemical storage |
Sources
- OSHA Occupational Chemical Database: Sucrose (accessed 2026-11-14)
- PubChem Compound Summary: Sucrose CID 5988 (accessed 2026-11-14)
- MilliporeSigma Sucrose SDS S0389 (accessed 2026-11-14)
- Fisher Scientific D-Sucrose SDS BP220 (accessed 2026-11-14)
- Carl Roth D(+)-Saccharose SDS 4621 (accessed 2026-11-14)
- Avantor VWR Sucrose SDS BDH0308 (accessed 2026-11-14)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.