Skip to main content
v2026.11,858 entries · CC-BY 4.0
LAC HealthMedical & Research SuppliesReagents, PPE & instruments — chain-of-custody documented.Fast, traceable sourcing built for regulated research environments, from bench consumables to instrumentation.Shop lac.us CodeCASRAIlac.us
GuideLaboratory Operations

Also relevant to: Mechanical & Aerospace Engineering

Supercritical CO2: What It Is, How It Works and Where It Is Used

What supercritical CO2 is, its NIST critical point, how density tuning and co-solvents work, reported extraction ranges and lab safety limits.

Written and maintained by CASRAI Editorial Board

Last updated

Short answer

Supercritical CO2 is carbon dioxide held above its critical point, 31.03 °C (304.18 K) and 73.8 bar (7.38 MPa), per the NIST Chemistry WebBook. Above that point it is a single dense fluid, not a liquid or a gas. Its solvent strength can be tuned with pressure and temperature, which is why it is used for extraction and chromatography.

Definition and the critical point

Every pure substance has a critical temperature and critical pressure. Above both, the liquid and gas phases no longer exist as separate phases and the substance becomes a supercritical fluid. For carbon dioxide, NIST Standard Reference Database 69 lists a critical temperature of 304.18 K (±0.04 K, Suehiro 1996) and a critical pressure of 73.80 bar (±0.15 bar). The triple point is 216.58 K at 5.185 bar.

Published values differ slightly between sources. NIST itself lists other reported critical temperatures from 304.1 to 304.35 K and other critical pressures of 73.40 and 73.825 bar, and the review cited below rounds to 31.1 °C and 73.8 bar. Use the NIST value when you need a citable figure, and treat the second decimal as source-dependent.

How it works in practice

Density tuning

The solvating power of a supercritical fluid follows its density. According to a review of supercritical fluid extraction of natural bioactive compounds (PMC7504334), raising pressure at constant temperature raises density and solvating power. Raising temperature at constant pressure lowers density, but it can also raise the vapor pressure of the solute, so the net effect on extraction varies by compound.

Change Effect on CO2 density Effect on extraction (as reported)
Pressure up, temperature constant Increases Solvating power increases
Temperature up, pressure constant Decreases Net effect varies: lower density, but possibly higher solute vapor pressure

The same review notes that very high pressure can compact the plant material in the vessel and reduce yield, so more pressure is not always better.

Why co-solvents are added

Pure CO2 is nonpolar. The review reports that polar or larger molecules need a modifier such as ethanol, methanol or water, with alcohol content frequently below 10%, and that ethanol is less toxic than methanol. Highly polar substances with a molecular weight above 400 are almost insoluble in CO2 even with tuning.

Why it leaves little residue

CO2 is a gas at ambient conditions, so when pressure is released the solvent leaves the extract with minimal residue. The review also describes it as non-toxic, easy to separate and an approved food-grade solvent, and notes that its low operating temperature suits heat-sensitive compounds.

Where it is used

The same review lists decaffeination, hops and spice extracts, alkaloids, artemisinin and cosmetic ingredients as applications of supercritical CO2 extraction. In analytical labs the fluid is the mobile phase in supercritical fluid chromatography; see SFC versus HPLC for how that differs from liquid chromatography. Outside the lab, the U.S. Department of Energy has published work on supercritical CO2 as the working fluid in power-generation Brayton cycles, a separate use of the same phase.

Reported operating windows (not recommendations)

The review reports the ranges below from published studies. They show the order of magnitude of conditions used, not settings to copy.

Parameter Reported range
Thermolabile compounds 35 to 60 °C at about 400 bar
Essential oils and terpenoids 90 to 120 bar at 35 to 50 °C
Sample moisture 4 to 14%
Particle size 0.25 to 2.0 mm

Where it matters for labs

Working above 73.8 bar means supercritical CO2 systems are pressure equipment, and CO2 itself is an exposure hazard when it is released into a room. NIOSH lists for carbon dioxide an IDLH (immediately dangerous to life or health) value of 40,000 ppm, revised down from 50,000 ppm in 1994, a recommended exposure limit of 5,000 ppm (9,000 mg/m3) as a time-weighted average, and a short-term limit of 30,000 ppm (54,000 mg/m3). Pressurized CO2 is supplied in cylinders; see the dictionary entry on compressed gas cylinder sizes, and for local exhaust and ventilation concepts see fume hood. Follow your institution’s pressure-equipment and gas-handling procedures and the instrument manufacturer’s instructions; this page does not replace them.

For downstream analysis of extracts, an evaporative detector is one option covered in evaporative light scattering detector.

Common misunderstandings

  • It is not a new state of matter. It is a fluid phase of the same substance above its critical point.
  • It is not a universal solvent. Pure CO2 is nonpolar and needs a modifier for polar compounds; very polar, high-molecular-weight substances stay almost insoluble.
  • Hotter is not automatically stronger. At constant pressure, higher temperature lowers density, so the net effect depends on the compound.
  • Residue-free does not mean hazard-free. Co-solvents add their own toxicity considerations, and CO2 has the exposure limits above.

FAQ

What is the critical point of CO2?

NIST lists 304.18 K (31.03 °C) and 73.80 bar (7.38 MPa). Other sources report values within a few hundredths of a kelvin and a few tenths of a bar.

Is supercritical CO2 a liquid or a gas?

Neither. Above the critical point there is one fluid phase with no liquid-gas boundary.

Why is supercritical CO2 used for extraction?

It is non-toxic, leaves little residue because it is a gas at ambient conditions, works at temperatures gentle on heat-sensitive compounds, and its solvating power can be adjusted through pressure and temperature.

Sources

  • NIST Chemistry WebBook, SRD 69, carbon dioxide (phase change data): webbook.nist.gov, read 2026-11-08.
  • NIOSH, Immediately Dangerous to Life or Health Values: carbon dioxide: cdc.gov/niosh/idlh/124389, read 2026-11-08.
  • Supercritical Fluid Extraction of Natural Bioactive Compounds (review), PMC7504334: pmc.ncbi.nlm.nih.gov, read 2026-11-08.
  • U.S. Department of Energy, Supercritical Carbon Dioxide Brayton Cycle: energy.gov (PDF).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Supercritical CO2: What It Is, How It Works and Where It Is Used

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →