Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
A three way stopcock is a valve fitting with three openings that sits in an intravenous line and is used for injection of medications, administration of IV infusions and collection of blood samples. In US regulation it is named as a component of an intravascular administration set, and CDC infection-control guidance treats it as an access point. Who uses it: nurses, anesthesia and critical-care staff, and the buyers who stock IV supplies for them.
What a three way stopcock is
The name describes the fitting: three ports joined at one valve body, with a handle that selects which ports are connected. CDC’s 2002 guideline describes stopcocks as devices “used for injection of medications, administration of IV infusions, and collection of blood samples”. For the rest of the IV line, see IV equipment: parts, pumps and FDA classes by role; for the connector-style alternative, see IV claves and needleless connectors.
Where it sits in an IV set (FDA class)
21 CFR 880.5440 defines an intravascular administration set as a device used to administer fluids from a container to a patient’s vascular system through a needle or catheter inserted into a vein. The regulation’s list of components includes “an I.V. set stopcock” alongside items such as an infusion line filter and fluid delivery tubing. The same section classifies the device type as Class II (special controls). Source: eCFR, 21 CFR 880.5440, checked 2026-11-03. Related set components: Y-type tubing and the IV drip chamber.
Stopcock versus piggyback system: what CDC says
| Option | What the CDC/HICPAC guideline says |
|---|---|
| Stopcock | A potential portal of entry for microorganisms into vascular access catheters and IV fluids; contamination reported in 45% and 50% in the majority of series. |
| Piggyback system | Described as an alternative to stopcocks. |
The same guideline adds that whether stopcock contamination is a substantial entry point for catheter-related bloodstream infection “has been difficult to prove”. Treat the figures as historical: the source is the 2002 MMWR Recommendations and Reports 51(RR-10), and a later update exists. Checked 2026-11-03.
Infection-control basics (CDC, 2002)
The guideline’s recommendations for stopcocks include capping them when not in use (Category IB) and cleaning injection ports before the system is accessed (Category IA). Facilities follow their own current policy and the product’s instructions for use; this page summarizes one published guideline.
FAQ
Is a three way stopcock an FDA-regulated device?
It is named as a component of the intravascular administration set in 21 CFR 880.5440, a Class II (special controls) device type.
Why is a stopcock an infection risk?
CDC describes it as a potential portal of entry for microorganisms into the catheter and IV fluids, while noting the contribution to bloodstream infection is hard to prove.
What is a stopcock used for?
CDC’s 2002 guideline describes stopcocks as used for injection of medications, administration of IV infusions and collection of blood samples.
Where to find infusion supplies
CASRAI does not sell products. LAC lists infusion supplies in its shop.
Sources
- eCFR, 21 CFR 880.5440 Intravascular administration set, https://www.ecfr.gov/current/title-21/section-880.5440, checked 2026-11-03.
- CDC/HICPAC, Guidelines for the Prevention of Intravascular Catheter-Related Infections, MMWR 2002;51(RR-10), https://www.cdc.gov/mmwr/preview/mmwrhtml/rr5110a1.htm, checked 2026-11-03.