Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
A Tono-Pen is a handheld electronic tonometer made by Reichert that estimates intraocular pressure (eye pressure) in millimetres of mercury (mmHg) by lightly touching the cornea. It is used by eye care clinicians and trained technicians. This guide explains how it is built, how it differs from the Icare rebound tonometer, which consumables it depends on, and where it sits in FDA’s device classification.
What a Tono-Pen is
Tono-Pen is Reichert’s brand name for a family of portable tonometers. The human-use model listed by Reichert, the Tono-Pen AVIA, uses a micro strain gauge transducer; Reichert describes it as less sensitive to corneal centration than other tonometers. Reichert also lists the Tono-Pen AVIA Vet for veterinary use. Who uses it: eye care clinicians, and technicians after what the manufacturer calls minimal training.
How it works and how it is built
The tip of the instrument contains the strain gauge transducer. The device records a series of brief taps at the tip and displays a pressure reading. Reichert’s AVIA page describes two modes: a First Generation mode that typically takes five taps, and a Quick-Tap mode that can take as few as two. Reichert states that routine calibration of the Tono-Pen AVIA is not required.
Power comes from a removable Powercel battery pack that the user can change without tools; Reichert describes it as capable of thousands of measurements.
Consumables: Ocu-Film and tip covers
Each measurement uses a single-use, sanitized Ocu-Film and Tip Cover. Reichert lists these covers as FDA cleared and notes that covers not made by Reichert may cause Tono-Pen readings to be erratic or inaccurate. The cover, not the handpiece, is the recurring item. Reichert’s veterinary starter kit is listed with 150 individually wrapped covers. Cleaning and disinfection of the handpiece is covered by the manufacturer’s own cleaning documents, which should be followed as written; for general disinfectant background see 70% isopropyl alcohol as a disinfectant.
Tono-Pen and Icare compared
People searching for a Tono-Pen often also meet the Icare tonometer, which uses a different principle. The Icare IC200, the current model on Icare’s US site, uses rebound tonometry and states that it needs no air puffs. The earlier Icare TA01i is marked retired on Icare’s site, which points to the IC200 as the latest model.
| Instrument | Principle and use | Stated range | Consumable |
|---|---|---|---|
| Tono-Pen AVIA (Reichert) | Micro strain gauge transducer at the tip; two measurement modes; no routine calibration | 5-55 mmHg | Single-use Ocu-Film and Tip Covers |
| Tono-Pen AVIA Vet (Reichert) | Same strain gauge approach with a 1.0 mm transducer tip; for veterinary professionals, 40+ cat and dog breeds, any position | 1-99 mmHg | Ocu-Film and Tip Covers (starter kit of 150) |
| Icare IC200 | Rebound tonometry; no air puffs; no calibration | 7-50 mmHg | Single-use probes (stated on the retired TA01i page) |
Icare states IC200 accuracy of ±1.2 mmHg at or below 20 mmHg and ±2.2 mmHg above 20 mmHg, with repeatability CV under 8%, a one-decimal mmHg display, a Quick Measure mode, and a probe-base indicator that shows green or red. It runs on four AA (LR6) batteries. Icare describes the IC200 as a professional tonometer for clinical, surgical and emergency settings.
Types and models at a glance
Human and veterinary Tono-Pen
The two Tono-Pen models differ mainly in intended patient and range: 5-55 mmHg for the human AVIA against 1-99 mmHg for the AVIA Vet. They are not interchangeable in intended use.
Icare tonometer
An “Icare tonometer” is a rebound instrument from a different manufacturer. Its disposable item is the probe rather than a film-and-cover set.
How it is regulated
Tonometers and accessories fall under 21 CFR 886.1930. In FDA’s openFDA classification database (checked 2026-10-30), product code HKX is titled “Tonometer, AC-Powered”, medical specialty Ophthalmic, device class 2. The classification is per product code; check a specific model’s FDA listing rather than assuming it from the brand name.
Safe use and handling basics
- Use the manufacturer’s own covers or probes; Reichert warns that other covers may give erratic or inaccurate readings.
- Covers and probes are single-use; Icare describes single-use probes as a way to avoid contamination between patients.
- Follow the manufacturer’s cleaning and disinfection documents for the handpiece.
- Measurement and interpretation belong to a trained clinician; this page gives no clinical guidance.
Common mistakes
- Assuming a Tono-Pen and an Icare work the same way: one touches the cornea with a strain gauge tip, the other uses rebound tonometry.
- Using the human-use model’s range for an animal patient, or the reverse.
- Treating the retired Icare TA01i as the current model.
- Substituting third-party tip covers.
FAQ
Who uses a Tono-Pen?
Eye care clinicians, and technicians after what Reichert calls minimal training. This page gives product information only, not guidance on measurement.
Does a Tono-Pen need calibration?
Reichert states that routine calibration of the Tono-Pen AVIA is not required, and its veterinary page says no daily calibration is needed.
What is an Icare tonometer?
It is a handheld rebound tonometer from Icare that measures eye pressure with a light single-use probe, with a stated range of 7-50 mmHg on the IC200. Icare states that the IC200 needs no air puff.
What does a Tono-Pen use for each measurement?
A single-use, sanitized Ocu-Film and Tip Cover. Related ophthalmic equipment is covered in the ophthalmoscope guide and the optometry clinic supply checklist. Clinic buyers can browse diagnostic, monitoring and imaging equipment as a category.
Sources
- Reichert, Tono-Pen AVIA product page, https://www.reichert.com/Products/Tono-Pen-AVIA (checked 2026-10-30)
- Reichert, Tono-Pen AVIA Vet product page, https://www.reichert.com/Products/Tono-Pen-AVIA-Vet (checked 2026-10-30)
- Icare, iCare IC200 tonometer, https://www.icare-world.com/us/product/icare-ic200-tonometer/ (checked 2026-10-30)
- Icare, iCare TA01i tonometer (retired), https://www.icare-world.com/us/product/icare-ta01i-tonometer/ (checked 2026-10-30)
- FDA openFDA device classification, product code HKX, 21 CFR 886.1930, https://api.fda.gov/device/classification.json?search=product_code:HKX (checked 2026-10-30)







