Skip to main content
v2026.11,986 entries · CC-BY 4.0

Trypan Blue SDS: Hazards, PPE, Storage and Disposal Compared

Trypan blue SDS side by side: all three sheets say H350, one adds H361. Compare PPE, storage, incompatibles and disposal wording.

Written and maintained by CASRAI Editorial Board

Published

On this page

A trypan blue SDS (safety data sheet) classifies the dye as a Category 1B carcinogen, hazard statement H350 “May cause cancer”, with the signal word Danger. Of the three manufacturer sheets compared here, one (Thermo Fisher) also lists Reproductive toxicity Category 2 (H361), while the other two do not. The sheet for your exact product governs.

Short answer: what the sheets agree on and where they differ

The three sheets compared on this page are the Thermo Fisher (Life Technologies) “Trypan Blue Stain” sheet, product code 15250061, revision date 26 September 2025; the STEMCELL Technologies “Trypan Blue” 0.4% sheet, effective 20 January 2016; and the Loba Chemie “Trypan Blue for Microscopy” sheet, dated 6/7/2024 as printed. Reading them side by side shows a clear pattern.

  • They agree that trypan blue (CAS 72-57-1) carries Carcinogenicity Category 1B, H350, the signal word Danger, and the response statement P308+P313 (if exposed or concerned, get medical advice or attention).
  • They differ on reproductive toxicity (H361 on one sheet, absent or “not classified” on the others), on which precautionary statements are printed, on glove and respiratory advice, and on incompatible materials.
  • They are not interchangeable. The sheets describe different products: a 0.1-1% solution, a 0.4% solution and a solid powder, issued in 2025, 2016 and 2024 under US and EU formats.

The data table below the guide sets the three sheets out attribute by attribute. The rest of this page explains how to read the entries that matter at the bench.

What a trypan blue SDS covers: identity and scope

Trypan blue is a diazo dye used in the lab mainly as a vital stain: cells with intact membranes exclude it, so counting stained and unstained cells under a microscope gives a viability estimate (see the guide to hemocytometer cell counting and viability). The safety data sheet is a separate question from the method: it is the supplier’s statement of hazards, handling, storage and disposal for the specific product in the bottle.

The sheets identify the substance by CAS number 72-57-1 and EC number 200-786-7. The Loba Chemie sheet adds EC Index number 611-024-00-1. PubChem, the US National Library of Medicine’s compound database, lists the tetrasodium salt (molecular formula C34H24N6Na4O14S4, molecular weight 960.8) under the title “C.I. Direct Blue 14”, which is the colour-index name you may see on some labels and older sheets. The STEMCELL sheet gives the same formula and states a molecular weight of 960.81.

Scope matters too. The Thermo Fisher sheet is marked “For research use only. Not for use in diagnostic procedures” and lists trypan blue at 0.1-1% by weight in the product. The STEMCELL sheet is for a 0.4% solution described as a dark blue liquid. The Loba Chemie sheet covers the solid substance, so its entries on dust, solubility and pH describe a powder, not a ready-to-use solution.

Trypan blue hazards: what H350 and H361 mean on the sheet

Carcinogenicity Category 1B and H350

All three sheets print “H350 – May cause cancer” under Carcinogenicity, Category 1B, with the Danger signal word and the health-hazard pictogram. The sheets state the category and the hazard statement and this page reports them as printed. For the wider picture of how agencies list carcinogens, see the IARC list of carcinogens.

The STEMCELL sheet also records, in its toxicology section, that IARC lists the substance in Group 2B (possibly carcinogenic to humans), and states that no component at or above 0.1% is identified as a carcinogen by ACGIH, NTP or OSHA. That wording is the supplier’s own text. It does not conflict with the H350 label, because the GHS classification and the IARC or ACGIH lists are separate systems, and that sheet itself prints both. The STEMCELL sheet also carries a California Proposition 65 warning that the product contains a chemical known to the State of California to cause cancer.

Reproductive toxicity Category 2 and H361

Only the Thermo Fisher sheet lists Reproductive toxicity Category 2, “H361 – Suspected of damaging fertility or the unborn child”. The STEMCELL sheet lists Carcinogenicity 1B alone. The Loba Chemie sheet states in its toxicology section that reproductive toxicity is “Not classified”. A person who reads only one sheet could therefore come away with a different understanding of the hazard than a colleague who reads another. If you work with the Thermo Fisher product, treat H361 as part of the label you are working under.

Acute toxicity and other classifications

The Thermo Fisher sheet gives an oral LD50 for rats of 6200 mg/kg and says its acute toxicity data are conclusive but insufficient for classification. The STEMCELL sheet reports no data available for oral, inhalation or dermal acute toxicity. The Loba Chemie sheet lists germ cell mutagenicity, reproductive toxicity and specific target organ toxicity as not classified. The Thermo Fisher sheet’s HMIS rating shows Health 4 with an asterisk, Flammability 0 and Reactivity 0.

How the SDS is used in practice at the bench

Every sheet follows the numbered-section format of the GHS safety data sheet, and the sections that decide day-to-day handling are the same on all three. Our guide to reading a safety data sheet walks through all sixteen sections; for trypan blue these are the ones to read first.

  • Section 2, hazards identification: the classification, signal word, pictogram and the H and P statements printed on the container label.
  • Section 7, handling and storage: container, ventilation and storage conditions.
  • Section 8, exposure controls and personal protection: occupational limits, engineering controls and PPE.
  • Section 10, stability and reactivity: conditions to avoid and incompatible materials.
  • Section 13, disposal: the waste route, which in practice is set by your institution as well as by the sheet.

Because H350 is a carcinogen classification, many laboratories manage such products as part of their chemical hygiene plan, with their own rules on designated areas, labelling and waste. The guide to particularly hazardous substances in the lab explains how select carcinogens are treated under that framework; your environmental health and safety office decides what applies in your building.

PPE and exposure controls compared

The three sheets give different levels of detail, which is itself useful information when you write a local procedure.

  • Gloves. Thermo Fisher names butyl rubber at 0.7 mm coating thickness or nitrile rubber at 0.4 mm, with a breakthrough time of more than 240 minutes. STEMCELL asks for gloves that are inspected before use and removed with the proper technique without touching the outer surface, and says to dispose of contaminated gloves according to applicable laws and good laboratory practice; it names no material. Loba Chemie says only “protective gloves”.
  • Eyes. Thermo Fisher: tight sealing safety goggles. STEMCELL: eye protection tested and approved to a government standard such as NIOSH (US) or EN 166 (EU). Loba Chemie: chemical goggles or safety glasses.
  • Body. Thermo Fisher: suitable protective clothing. STEMCELL: impervious clothing. Loba Chemie lists “wear a mask” under skin and body protection.
  • Respiratory. Thermo Fisher: respirators only if ventilation is insufficient. STEMCELL: respiratory protection not required, with OV/AG (US) or ABEK (EU) cartridges for nuisance exposures. Loba Chemie: wear an appropriate mask.
  • Engineering controls. Thermo Fisher: adequate ventilation, especially in confined areas. STEMCELL: mechanical exhaust or a laboratory fume hood. Loba Chemie: good ventilation of the work station.
  • Exposure limits. The Thermo Fisher sheet’s table of OSHA PEL and ACGIH OEL values lists none for trypan blue; the STEMCELL sheet says the product contains no substances with occupational exposure limit values; the Loba Chemie sheet gives no national limit values.

The practical reading is that no sheet sets a numerical exposure limit, so the controls are qualitative. A fume hood or other local exhaust is named explicitly only by the STEMCELL sheet, which is the one for a ready-made solution; the Loba Chemie sheet covers the powder, where dust is the realistic route of exposure, and it asks for good ventilation and a mask. Neither sheet states a weighing or dust-control procedure, so that part comes from your own risk assessment.

Storage conditions and incompatible materials

Storage wording varies more than the classification does. Thermo Fisher says to keep the product in a dry, cool and well-ventilated place, in properly labelled containers, and to store it in accordance with local regulations; its section 2 lists storage precautionary statements as not applicable. STEMCELL says to keep the container tightly closed in a dry, well-ventilated place and to reseal opened containers carefully and keep them upright to prevent leakage. Loba Chemie says to store in the original container, tightly closed, in a dry place, protected from moisture and locked up, in a cool, well-ventilated place away from heat; its section 10 lists direct sunlight, air contact and moisture as conditions to avoid.

“Store locked up” appears only on the Loba Chemie sheet, which is the one for a solid powder classified H350. The instruction is not printed on the other two sheets.

On incompatibilities the sheets give three answers. Thermo Fisher: “No dangerous reaction known under conditions of normal use.” STEMCELL: strong oxidizing agents. Loba Chemie: no additional information available, and no dangerous reactions known under normal conditions of use. For a bench that segregates by compatibility class, a cautious reading is to keep trypan blue away from strong oxidizers, since one supplier names them; the guide to chemical storage compatibility and segregation covers the general rules.

Spills, fire and disposal

For spills, Thermo Fisher says to soak up with inert absorbent material and to avoid discharge into drains and waterways whenever possible. STEMCELL says to soak up with inert absorbent material and dispose of it as hazardous waste, keeping it in suitable, closed containers, and not to let the product enter drains. In fire, the Thermo Fisher sheet lists water spray, carbon dioxide, foam and dry chemical as suitable extinguishing media; the STEMCELL sheet describes the product as not flammable or combustible.

For disposal, the Thermo Fisher sheet prints P501 (dispose of contents and container to an approved waste disposal plant) and says disposal of the product, its solutions and any by-products must comply with all applicable regulations. The Loba Chemie sheet says to dispose of contents and container according to the licensed collector’s sorting instructions and official regulations, and not to re-use empty containers. The STEMCELL sheet points to a licensed disposal company for surplus product. None of the three tells you which waste stream to use in your building. That is set by your institution’s waste programme; your EHS office can tell you which container and accumulation area to use.

On transport, the Thermo Fisher and Loba Chemie sheets say the product is not regulated for transport, and the STEMCELL sheet lists it as not dangerous goods under DOT, ADR, IMDG and IATA. Being outside dangerous-goods transport rules says nothing about the laboratory classification: all three are classified H350 and still ship as unregulated goods.

Why the sheets differ

Three ordinary factors explain most of the differences, and none of them means a sheet is wrong.

  1. The product is different. A 0.1-1% solution, a 0.4% solution and a solid powder do not present the same exposure routes, so a sheet for the powder emphasises masks and ventilation at the work station, and a sheet for a solution emphasises splashes, gloves and spills. The pH figures reflect this: Thermo Fisher gives pH 6-8 for the liquid, and Loba Chemie gives pH 9.8 for a 1% solution of the solid at 20 °C, with water solubility of 10 mg/mL.
  2. The sheets have different dates and formats. The sheets here were issued in 2016, 2024 and 2025. The Loba Chemie sheet follows the EU REACH format as amended by Regulation (EU) 2020/878 and uses CLP wording; the Thermo Fisher and STEMCELL sheets are in the US-style GHS layout, with entries such as HMIS and SARA 313 (Thermo Fisher) and Proposition 65 (STEMCELL). Each supplier decides how much of the available classification data to adopt, and classification can be revised between versions.
  3. Regulatory-list entries depend on the jurisdiction. Trypan blue is also listed on the EU Prior Informed Consent list (Regulation EU 649/2012) on the Loba Chemie sheet, and as a SARA 313 and TSCA-listed chemical on the Thermo Fisher sheet.

The consequence is a simple working rule. Use the sheet issued for the exact product, catalogue number and lot you hold, from the supplier you bought it from, and check its revision date. A sheet from another supplier, even for the “same” dye at the same concentration, is a comparison point, not a substitute. Our guide to how to get a current SDS covers where to find the current version; for a close parallel among lab stains, see crystal violet SDS.

Where it matters for labs and EHS officers

Trypan blue is usually a small-volume reagent in cell culture, so its SDS is easy to skim past. Three decisions depend on it.

  • Whether to treat it as a carcinogen in your inventory. All three sheets say H350. Putting the product on your hazardous-chemical inventory and labelling working dilutions is an institutional policy question, informed by the label statements above.
  • Which sheet goes in the binder or SDS system. If different groups buy from different suppliers, the same dye will appear with different classifications (H350 alone, or H350 with H361) and different PPE text. A single local procedure should name the strictest classification among the products actually in use.
  • What happens to the waste. Counting-chamber slides, pipette tips and the stained cell suspension carry the dye. The sheets say disposal must follow local regulations and approved routes; the routing itself is your EHS office’s call.

Common misunderstandings about the trypan blue SDS

  • “It is only a stain, so it is low hazard.” The label classification on all three sheets is a carcinogen (H350) with the Danger signal word.
  • “Every supplier’s sheet says the same thing.” They do not: reproductive toxicity, P-statements, glove materials and incompatible materials all differ between the three sheets here.
  • “Not regulated for transport means not hazardous.” Transport classification and laboratory hazard classification are separate, as shown above.
  • “No exposure limit means no precautions.” The sheets list no OSHA PEL or ACGIH OEL, yet all of them ask for protective equipment, ventilation and controlled disposal.
  • “MSDS and SDS are different documents.” The older term MSDS is still used in searches and file names, and the STEMCELL file name still carries it, but the documents are the same thing. The sheets here are in the SDS format.

Sources

Data: Trypan blue safety data sheets compared: Thermo Fisher, STEMCELL and Loba Chemie

Attribute-by-attribute comparison of three manufacturer safety data sheets for trypan blue (CAS 72-57-1): product form, classification, hazard and precautionary statements, PPE, storage, incompatibles, exposure limits and transport wording. Compiled by reading each supplier's SDS PDF in full; each cell restates what that sheet prints, and 'not stated' means the sheet gives no entry.

Period covered: 2016/2025.

Trypan blue safety data sheets compared: Thermo Fisher, STEMCELL and Loba Chemie
AttributeThermo Fisher 15250061STEMCELL 00654/07050Loba Chemie 06397
Product formLiquid, 0.1-1 wt% trypan blue, pH 6-8Dark blue liquid, 0.4%Solid powder
Signal wordDangerDangerDanger
CarcinogenicityCategory 1B, H350Category 1B, H350Category 1B, H350
Reproductive toxicityCategory 2, H361Not listedNot classified
Precautionary statements printedP201, P202, P280, P308+P313, P501P201, P202, P280, P308+P313P201, P308+P313
GlovesButyl rubber 0.7 mm or nitrile 0.4 mm, breakthrough over 240 minInspected gloves, proper removal technique; material not statedProtective gloves; material not stated
Eye protectionTight sealing safety gogglesEye protection to NIOSH or EN 166Chemical goggles or safety glasses
Respiratory protectionRespirator only if ventilation is insufficientNot required; OV/AG or ABEK cartridges for nuisance exposureWear an appropriate mask
Engineering controlsAdequate ventilationMechanical exhaust or laboratory fume hoodGood ventilation of the work station
Occupational exposure limitsNo OSHA PEL or ACGIH OEL listedNo substances with OEL valuesNo additional information
Incompatible materialsNo dangerous reaction known under normal useStrong oxidizing agentsNo additional information available
Storage wordingDry, cool, well ventilated, labelled containersTightly closed, dry, well ventilated; reseal and keep uprightOriginal container, tightly closed, dry, protect from moisture, locked up, cool and away from heat
Transport classificationNot regulatedNot dangerous goodsNot regulated

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Trypan Blue SDS: Hazards, PPE, Storage and Disposal Compared

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →