Written and maintained by CASRAI Editorial Board
Published
On this page
This page describes products and general use; it is not medical advice. A surgeon chooses and manages any drain for a specific patient.
Searchers use “types of drains” for two different things: plumbing drains and surgical wound drains. This page is about surgical drains, and the plumbing question is answered briefly in the FAQ. After reading it you should be able to tell the main surgical drain types apart by how they work, what they are made of and how they are sized.
Overview: what are the different types of surgical drains?
Surgical drains are usually sorted two ways. First, open or closed. According to StatPearls, a closed system has an outflow tube and a collection chamber and works by gravity or negative pressure, while in an open system fluid flows freely from the wound to the outside. Second, passive or active, meaning whether suction is applied. Sources differ on where some drains sit in this second split; the pigtail drain in particular is classified differently depending on the source.
StatPearls (read 2026-11-07) names these closed examples: pigtail, Jackson-Pratt, Blake and active negative-pressure (wound vac) systems. Its open example is the Penrose drain.
Types table
| Drain | System | What it is | Limits and notes |
|---|---|---|---|
| Penrose | Open | Soft tube that drains by capillary action and gravity, used for superficial spaces. Made of polypropylene, latex or silastic, in various widths, cut to length. | Open drainage means no collection chamber. Latex versions matter for latex-sensitivity checks. |
| Jackson-Pratt (JP) | Closed | Closed-suction drain with tubing connected to a collection reservoir. | The reservoir is emptied and the output recorded. See the drainage catheter stocking guide for reservoir volumes. |
| Blake | Closed | Silicone drain with channels instead of holes, connected to a suction reservoir. Details in the Blake drain guide. | Single-use and sterile; indications are defined only in the manufacturer package insert. |
| Pigtail | Closed | Drain with a curled tip held by securing strings; the strings are released so the tip uncoils. | Classification as passive or active varies by source. |
| Negative-pressure wound therapy (wound vac) | Closed, active | Applies continuous suction to a wound. See what is a wound vac. | Regulated separately from manual suction drains (see below). |
Hemovac-style spring reservoirs are covered in the stocking guide above, and chest drainage in what is a chest tube.
Who chooses the drain, and in which setting
Drain selection is a clinical decision made for the procedure and wound; this page does not give setting-by-setting recommendations. What differs in practice is what staff handle afterwards. Closed-suction systems have a reservoir that is emptied and recorded, as described by StatPearls, while an open Penrose drain drains outward into the dressing.
What to check on the label
- Tubing size. StatPearls states that round tubing is sized in French and flat tubing in millimetres.
- Material. Closed-system tubing is typically silicone. Penrose drains come in polypropylene, latex or silastic, so read the latex statement.
- Reservoir. Check whether a reservoir is included or separate; the suction canister guide covers related collection devices.
- Single-use and sterile status. The manufacturer packaging and instructions for use state this for each product.
Regulatory status of manual suction drains
Under 21 CFR 878.4680 (read 2026-11-07), a manually operated, plastic, disposable evacuation system is intended to provide a vacuum for suction drainage of surgical wounds. It is Class I (general controls) and exempt from 510(k) subject to 878.9. Negative-pressure wound therapy suction apparatus is a separate device under 21 CFR 878.4683 and is Class II (special controls).
Care and replacement
StatPearls describes these care points for suction drains, carried out by clinical staff or as taught by the care team: strip the tubing regularly, empty the reservoir when full or on a schedule and record the volume, handle it sterilely, change the dressing daily, inspect the site at least twice daily and notify the surgeon of changes. Removal typically follows when drainage decreases to a minimal level; no single threshold is given. This page does not describe insertion or removal steps.
FAQ
What are the different types of drainage systems?
For surgical drains: open (Penrose) and closed (Jackson-Pratt, Blake, pigtail, wound vac), and passive or active depending on whether suction is applied.
What are the different types of surgical drains?
The table above lists them. The most commonly named are Penrose, Jackson-Pratt, Blake and pigtail, with Hemovac and chest tubes covered on linked pages.
What is the difference between a drain and a pipe?
In plumbing, a drain is the opening or fixture where water leaves and the pipe carries it away. A surgical drain is a different device: a tube placed to remove fluid from a wound.
What are the differences between perforated PVC and corrugated PVC pipe?
Perforated pipe has holes that let water in, while corrugated pipe has a ribbed wall. These are building products and fall outside this site’s medical supply coverage.
Sources
- StatPearls, “Suction Drains”: https://www.ncbi.nlm.nih.gov/books/NBK557687/ (read 2026-11-07).
- eCFR, 21 CFR 878.4680, manual evacuation systems: https://www.ecfr.gov/current/title-21/part-878/subpart-E/section-878.4680 (read 2026-11-07).