UN1170 is the United Nations identification number for ethanol (ethyl alcohol) and its solutions. In the U.S. Hazardous Materials Table (49 CFR 172.101) it is a Class 3 flammable liquid, listed under two packing groups: Packing Group II (non-bulk packaging in 49 CFR 173.202) and Packing Group III (49 CFR 173.203). Which one applies to a given bottle is decided by the liquid’s own flash point and initial boiling point, not by the UN number.
Short answer: what UN1170 means
The entry reads “Ethanol or Ethyl alcohol or Ethanol solutions or Ethyl alcohol solutions”, hazard class 3, identification number UN1170, label code 3. The same four-digit number covers pure ethanol and ethanol solutions. It does not by itself tell a shipper the packing group, the packaging section, or the quantity limit: the table gives two rows, and each row carries different columns. The data table below sets the two rows side by side.
Definition and scope
A UN number is a four-digit identifier assigned to a hazardous substance or group of substances. In the United States, the identification number appears in column 4 of the Hazardous Materials Table at 49 CFR 172.101, next to the proper shipping name (column 2), the hazard class (column 3) and the packing group (column 5). For UN1170 the proper shipping name is “Ethanol” or “Ethyl alcohol” or the solution variant, and the hazard class is 3, flammable liquids.
This page describes the domestic U.S. entry as it appears in the version of Title 49 current on 2026-10-01. Air and sea shipments are governed by the international modal rules (the IATA Dangerous Goods Regulations and the IMDG Code); the U.S. table does carry columns for aircraft and vessel limits, and those are reproduced below, but the international editions are separate documents with their own revision cycle. Laboratories that ship by air should read the guide to the IATA Dangerous Goods Regulations alongside this page, because the modal limits in an airline’s acceptance rules can differ from the 49 CFR columns.
Ethanol is a flammable liquid, so UN1170 sits alongside the other Class 3 laboratory solvents. For the broader class, see hazmat Class 3 flammable liquids. Isopropyl alcohol, the other common lab alcohol, has its own number; the neighbouring entry for that solvent is covered in UN1993, and the practical differences between the two alcohols are in the isopropyl alcohol vs ethanol comparison.
What UN1170 means in practice: the two table rows
The Hazardous Materials Table lists UN1170 twice. Both rows share the proper shipping name, the hazard class 3, the label code 3, the exceptions section 150 (49 CFR 173.150), the bulk packaging section 242, and vessel stowage code A. They differ in the special provisions, the non-bulk packaging section and the quantity limits for aircraft.
Packing Group II row
The Packing Group II row lists special provisions 24, IB2, T4 and TP1, non-bulk packaging section 202, a maximum of 5 L per package on passenger aircraft or passenger rail, and a maximum of 60 L per package on cargo aircraft.
Packing Group III row
The Packing Group III row lists special provisions 24, B1, IB3, T2 and TP1, non-bulk packaging section 203, a maximum of 60 L on passenger aircraft or rail, and a maximum of 220 L on cargo aircraft.
The practical effect is that the same four-digit number carries a twelve-fold difference in the passenger-aircraft limit (5 L against 60 L) depending on the packing group. Anyone quoting a single packing group for UN1170 without saying which solution it applies to is giving only half of the entry.
How the packing group is decided
49 CFR 173.121(a) states that when the Hazardous Materials Table provides more than one packing group for a material, the packing group must be determined from two properties measured on the material being shipped: the closed-cup flash point and the initial boiling point.
- Packing Group I applies when the initial boiling point is 35 °C (95 °F) or lower. Ethanol is not listed in this group in the table.
- Packing Group II applies when the flash point is below 23 °C (73 °F) and the initial boiling point is above 35 °C (95 °F).
- Packing Group III applies when the flash point is at least 23 °C and at most 60 °C (73 °F to 140 °F) and the initial boiling point is above 35 °C (95 °F).
The initial boiling point may be determined with ASTM D 86, ASTM D 1078, ISO 3405, ISO 3924, ISO 4626 or, for petroleum products containing known flammable gases, ASTM D7900, as listed in paragraph (a)(2). In practice this means the packing group follows the concentration and composition of the ethanol solution, because that is what moves the flash point. The safety data sheet for the specific product is where that flash point is normally reported; the regulation itself sets the criteria and leaves the value to the shipper’s classification of the actual material.
Packaging authorised for each row
Both non-bulk sections authorise combination packagings built from the same list of outer packagings: steel, aluminum, plywood, fiber and plastic drums; steel, aluminum and plastic jerricans; and boxes of steel, aluminum, natural wood, plywood, reconstituted wood, fiberboard, expanded plastic, solid plastic and other metal (specification codes 4A, 4B, 4C1, 4C2, 4D, 4F, 4G, 4H1, 4H2 and 4N). The inner packagings are glass or earthenware, plastic, or metal receptacles, or glass ampoules, so the ordinary glass and plastic laboratory bottle is an authorised inner packaging in a combination.
The differences are in the performance level and in single packagings:
- Section 173.202 (Packing Group II) requires packagings meeting Part 178 at the Packing Group I or II performance level, and single packagings are not authorised for passenger aircraft.
- Section 173.203 (Packing Group III) accepts Part 178 packagings at the Packing Group I, II or III performance level.
A packaging type being listed does not make a shipment compliant on its own: each packaging must also meet the general packaging requirements of subpart B of Part 173 and the special provisions in column 7 of the table.
Limited quantities under 173.150
Column 8A of both UN1170 rows points to 49 CFR 173.150, the exceptions section for flammable and combustible liquids. Paragraph (b) provides the limited-quantity exception. A limited-quantity package that conforms to the section is excepted from the labeling requirements unless the material is offered or transported by aircraft, and is excepted from specification packaging when it is a combination packaging according to the paragraph. Packages may not exceed 30 kg (66 pounds) gross weight, and other than for aircraft, the inner packaging limits are:
- Packing Group II: inner packagings not over 1.0 L (0.3 gallons) net capacity each, in a strong outer packaging.
- Packing Group III: inner packagings not over 5.0 L (1.3 gallons) net capacity each, in a strong outer packaging.
The paragraph adds three conditions that laboratories often miss. A limited-quantity package is not subject to the shipping paper requirements unless the material is a hazardous substance, hazardous waste or marine pollutant, or is offered and transported by aircraft or vessel. Limited-quantity shipments are not subject to the placarding rules in subpart F of Part 172. And for transportation by aircraft the package must also conform to 49 CFR 173.27, and only material authorised aboard passenger-carrying aircraft may move as a limited quantity.
Where it matters for labs and supply decisions
Laboratories meet UN1170 in three places: receiving ethanol shipments from suppliers, sending ethanol or ethanol-containing reagents to collaborators or service providers, and consolidating waste for disposal. For shipping, the points sourced above translate into questions to put to the safety data sheet and the carrier’s rules before the package is closed:
- Is the material the solution you think it is? A reagent that is mostly water can fall outside the table entirely (see below).
- Which packing group does the product’s flash point and boiling point give under 173.121? The answer drives the packaging section (202 or 203) and the passenger-aircraft limit (5 L or 60 L).
- Is the receptacle within the 1.0 L or 5.0 L inner limit if the limited-quantity route is being used?
- If the package goes by air, have the aircraft columns and the carrier’s own rules been checked, since 173.150(b) adds the 173.27 conditions for aircraft?
The emergency-response side is also keyed to the number. In the NOAA CAMEO Chemicals UN/NA lookup, UN1170 links to the “Ethanol” and “Ethanol, solution” datasheets and to Response Guide 127, “Flammable Liquids (Water-Miscible)”, from the Emergency Response Guidebook 2024. Ethanol’s physical properties, including its boiling point, are on the ethanol boiling point page.
Common misunderstandings
“UN1170 is Packing Group II” or “UN1170 is Packing Group III”
Both statements are incomplete. The table has a row for each, and the rule in 173.121 says the shipper selects between them using the material’s flash point and initial boiling point. Sources that give one packing group are usually describing one typical product.
Special provision 24 is a rule for laboratory ethanol
Both rows carry special provision 24, and it is easy to read it as a general ethanol rule. Its text in 49 CFR 172.102 is about alcoholic beverages: those with more than 70 percent alcohol by volume must be transported as Packing Group II, and those with more than 24 percent but not more than 70 percent alcohol by volume as Packing Group III. It is written for beverages, so it should not be extended to laboratory ethanol or other ethanol solutions.
Every ethanol solution is a UN1170 shipment
Not all of them. Under 173.150(e), an aqueous solution containing 24 percent or less alcohol by volume and no other hazardous material may be reclassed as a combustible liquid, and is not subject to the subchapter at all if it contains no less than 50 percent water. The reclassification condition is about the solution containing no other hazardous material, so a reagent mix with additional hazardous components does not qualify on the alcohol content alone.
Passing the limited-quantity test removes all requirements
It removes specific ones: specification packaging, labeling (not for aircraft), shipping papers (with the exceptions listed above) and placarding. The package must still conform to subpart B of Part 173 and stay within 30 kg gross weight.
Frequently asked questions
What packing group is UN1170?
The Hazardous Materials Table lists both Packing Group II and Packing Group III. Under 49 CFR 173.121 the group is chosen from the material’s flash point (below 23 °C for II, 23 to 60 °C for III) and an initial boiling point above 35 °C.
What hazard class is UN1170?
Class 3, flammable liquid, with label code 3, as shown in 49 CFR 172.101.
What is the passenger-aircraft limit for UN1170?
The table shows 5 L for the Packing Group II row and 60 L for the Packing Group III row; cargo aircraft limits are 60 L and 220 L. Carriers and the IATA regulations can impose their own conditions, so check the current edition of the modal rules before shipping by air.
Is UN1170 the same as UN1993?
No. UN1170 is ethanol and ethanol solutions. UN1993 is a different entry, described in the UN1993 guide.
Sources
- eCFR, 49 CFR 172.101 Hazardous Materials Table (Title 49 as of 2026-10-01), https://www.ecfr.gov/current/title-49/section-172.101, read 2026-11-15.
- eCFR, 49 CFR 172.102 Special provisions (provision 24), https://www.ecfr.gov/current/title-49/section-172.102, read 2026-11-15.
- eCFR, 49 CFR 173.121 Class 3 assignment of packing group, https://www.ecfr.gov/current/title-49/section-173.121, read 2026-11-15.
- eCFR, 49 CFR 173.150 Exceptions for Class 3 flammable and combustible liquids, https://www.ecfr.gov/current/title-49/section-173.150, read 2026-11-15.
- eCFR, 49 CFR 173.202 and 173.203 Non-bulk packagings for liquids, Packing Group II and III, https://www.ecfr.gov/current/title-49/section-173.202, read 2026-11-15.
- NOAA CAMEO Chemicals, UN/NA 1170 lookup (ERG 2024), https://cameochemicals.noaa.gov/unna/1170, read 2026-11-15.
Data: UN1170 ethanol: the two Hazardous Materials Table rows compared
Side-by-side comparison of the Packing Group II and Packing Group III rows for UN1170 (ethanol and ethanol solutions) in the 49 CFR 172.101 Hazardous Materials Table, combined with the packing-group criteria of 173.121 and the limited-quantity inner packaging limits of 173.150. Compiled by reading the eCFR text of Title 49 current on 2026-10-01.
Period covered: 2026-10-01. Coverage: United States.
| Attribute | Packing Group II row | Packing Group III row |
|---|---|---|
| Hazard class / label | 3 / 3 | 3 / 3 |
| Special provisions (column 7) | 24, IB2, T4, TP1 | 24, B1, IB3, T2, TP1 |
| Exceptions section (column 8A) | 150 | 150 |
| Non-bulk packaging section | 202 | 203 |
| Bulk packaging section | 242 | 242 |
| Passenger aircraft or rail maximum per package | 5 L | 60 L |
| Cargo aircraft maximum per package | 60 L | 220 L |
| Vessel stowage code | A | A |
| Flash point criterion (173.121) | Below 23 C (73 F), initial boiling point above 35 C | 23 C to 60 C inclusive, initial boiling point above 35 C |
| Part 178 performance level required | Packing Group I or II | Packing Group I, II or III |
| Limited quantity inner packaging, non-aircraft (173.150(b)) | 1.0 L maximum | 5.0 L maximum |
Sources
- eCFR 49 CFR 172.101 (accessed 2026-11-15)
- eCFR 49 CFR 173.121 (accessed 2026-11-15)
- eCFR 49 CFR 173.150 (accessed 2026-11-15)
- eCFR 49 CFR 173.202 (accessed 2026-11-15)
- eCFR 49 CFR 173.203 (accessed 2026-11-15)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.