Skip to main content
v2026.11,986 entries · CC-BY 4.0

Urea SDS: Hazards, GHS Classification, PPE and Storage

What a urea safety data sheet says: not classified under GHS, yet sheets differ on exposure limits, PPE, bleach incompatibility and disposal.

Written and maintained by CASRAI Editorial Board

Published

On this page

A urea safety data sheet (SDS) for the common lab and technical grade, CAS 57-13-6, normally says the substance is not classified as hazardous under the OSHA Hazard Communication Standard or GHS, so it carries no pictogram, signal word or H-statement. That is not the same as “no precautions”: the sheets still call for dust control, eye and hand protection, dry storage away from strong oxidizers and chlorine bleach, and disposal through the waste route your site defines.

What an SDS for urea says

Urea (carbamide, carbonyldiamide; formula CH4N2O, about 60.06 g/mol) is sold to laboratories as granules, prills or crystals and as a reagent-grade powder. Safety data sheets for it follow the standard 16-section layout, and most of the information you need sits in a handful of sections: 2 (hazard identification), 7 (handling and storage), 8 (exposure controls and PPE), 10 (stability and reactivity), 11 (toxicology) and 13 (disposal). If you are new to the format, the guide on how to read a safety data sheet walks through all sixteen sections.

Two supplier sheets illustrate the usual picture. The Sigma-Aldrich (Fluka) urea sheet, version 4.3 dated 24 February 2014 and hosted on a University of Washington safety site, states in section 2 that urea is “not a hazardous substance or mixture” and lists no label elements. The Lab Alley sheet for Urea Granules 99% Lab Grade (issue date 12/11/2023, revision 11/12/2024) states that the chemical “is not considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200)” and that no label elements are required. Both report the same oral LD50 in the rat, 8,471 mg/kg.

The data table below compares the Sigma-Aldrich (Fluka) sheet, the Lab Alley sheet and the ILO/WHO International Chemical Safety Card for urea on thirteen points, so that you can see where they agree and where they do not.

Why urea sheets differ from one another

“Not classified” is the shared headline, but the sheets are not interchangeable. The differences below come straight from the three documents in the data table.

  • Exposure limit. The Sigma-Aldrich sheet lists a time-weighted average of 10 mg/m3, with the basis given as the USA Workplace Environmental Exposure Level (WEEL). The Lab Alley sheet says the product contains no materials with occupational exposure limits established by the regional regulatory bodies. Neither statement contradicts the other: one cites a voluntary guideline value, the other speaks to regulatory limits.
  • Skin and eye data. The Sigma-Aldrich sheet reports no skin irritation and no eye irritation in rabbit tests. The Lab Alley sheet gives “no information available” for both endpoints, and the ICSC card says the substance is irritating to the eyes, skin and respiratory tract. A reader who only saw one document would draw a different conclusion from each.
  • Mutagenicity wording. The Lab Alley sheet includes the line “Mutagenic effects have occurred in experimental animals” under germ cell mutagenicity, and notes that the toxicological properties have not been fully investigated. The Sigma-Aldrich sheet’s germ cell mutagenicity entry lists mouse lymphocyte DNA damage and mouse cytogenetic analysis results. Neither sheet classifies urea for mutagenicity, and the Lab Alley sheet lists urea as not listed by IARC, NTP, ACGIH or OSHA for carcinogenicity.
  • Incompatibilities. The Sigma-Aldrich sheet names strong oxidizing agents only. The Lab Alley sheet adds chlorine and sodium hypochlorite. The ICSC card is the longest list: strong oxidants, nitrites, inorganic chlorides, chlorites and perchlorates, with the note that these reactions generate a fire and explosion hazard.
  • Thermal decomposition. The Sigma-Aldrich sheet gives no decomposition temperature and lists carbon oxides and nitrogen oxides as hazardous combustion products. The Lab Alley sheet says decomposition begins at 180 °C and names nitrogen oxides, carbon monoxide, carbon dioxide and ammonia. The ICSC card says urea decomposes on heating above its melting point (132.7 to 135 °C) and produces toxic gases.

The age of a sheet matters too. The Sigma-Aldrich copy is a 2014 revision, so a current supplier sheet for the same catalogue item may differ in wording. When two sheets for the same chemical disagree, the practical rule in a lab is to follow the more conservative statement for the task you are doing and to use the sheet that came with, or is linked from, the container you actually hold.

The aggregated classification picture

PubChem aggregates the GHS classifications that companies notify to the European Chemicals Agency (ECHA) Classification and Labelling Inventory. For urea (PubChem compound 1176), it reports that the chemical does not meet GHS hazard criteria in 96.1% (4,430 of 4,611) of all company reports. The aggregate comes from 23 notifications to the inventory, and 18 of those notifications, covering 181 of the 4,611 reports, carry hazard statement codes. PubChem notes that “information may vary between notifications depending on impurities, additives, and other factors.”

The practical reading: for plain urea the overwhelming majority of suppliers classify it as non-hazardous, but a minority classify it, and that is the reason for checking the specific sheet that ships with your grade and supplier rather than assuming one classification applies everywhere. This is also why a solution, a fertilizer blend or a product containing additives can carry hazard statements that pure urea does not. For how classification, pictograms and signal words fit together, see GHS classification of chemicals and NFPA 704 fire diamond versus GHS labels. The Sigma-Aldrich sheet gives HMIS ratings of 0 for health, flammability and physical hazard, and NFPA ratings of 0 for health, fire and reactivity. The Lab Alley sheet gives NFPA ratings of 1 for health, 0 for flammability and 0 for instability.

Urea hazards in the lab: dust, decomposition and incompatibilities

Dust

The ICSC card says urea is not combustible, but it advises preventing dispersion of dust. It states that evaporation at 20 °C is negligible while a nuisance-causing concentration of airborne particles can be reached quickly, especially if the material is powdered, and that repeated or prolonged skin contact may cause dermatitis. Both supplier sheets say to avoid dust formation during handling. For spills, the ICSC card says to sweep the spilled substance into covered containers, moistening first if appropriate to prevent dusting, and the supplier sheets say to sweep up and shovel into suitable containers for disposal.

Heat and fire

Urea is not itself a fire hazard in these documents, but heating it produces decomposition gases. The Lab Alley sheet names ammonia among them, and its section 9 lists an ammonia-like odour. Suitable extinguishing media on the Lab Alley sheet are water spray, carbon dioxide, dry chemical and chemical foam. The Sigma-Aldrich sheet lists water spray, alcohol-resistant foam, dry chemical and carbon dioxide.

Chlorine bleach and other incompatible materials

The incompatibility line is the most useful hazard statement on a urea sheet for a working lab. Strong oxidizers are named on all three documents, and two of them specifically name chlorine-based materials: the Lab Alley sheet lists chlorine and sodium hypochlorite, and the ICSC card lists inorganic chlorides, chlorites and perchlorates. Bleach is the common laboratory reagent that falls into this group. If your protocols involve urea-containing buffers or urea waste, check how your site treats the waste stream before anything containing hypochlorite is added to it. The sheets state the incompatibility; they do not describe the reaction products, and this page does not infer them.

PPE and exposure controls

The documents agree on a modest PPE set, expressed in different levels of detail.

  • Eyes. Lab Alley specifies protective eyeglasses or chemical safety goggles as described in OSHA 29 CFR 1910.133 or EN 166. The Sigma-Aldrich sheet specifies eye protection tested and approved under standards such as NIOSH (US) or EN 166 (EU). The ICSC card says to wear safety spectacles.
  • Hands. The Sigma-Aldrich sheet gives the most specific recommendation: nitrile rubber, minimum layer thickness 0.11 mm, breakthrough time 480 minutes for both full and splash contact, tested on a Dermatril glove (KCL 740, size M) by the test method EN 374. The sheet adds that the recommendation applies to the substance as supplied and that if urea is used in solution or mixed with other substances, or under conditions that differ from EN 374, you should contact the glove supplier. Lab Alley says to wear appropriate gloves and clothing without naming a material.
  • Respiratory. Sigma-Aldrich says respiratory protection is not required, and that for nuisance levels of dust where protection is desired, an N95 (US) or type P1 (EN 143) dust mask may be used. Lab Alley refers to OSHA 29 CFR 1910.134 or EN 149 and says to use an approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. The ICSC card lists local exhaust as the prevention measure for inhalation.
  • Engineering controls. Lab Alley calls for adequate ventilation, especially in confined areas, and for eyewash stations and safety showers close to the workstation.

Storage and disposal

Storage language is consistent: the Sigma-Aldrich sheet says to keep the container tightly closed in a dry and well-ventilated place; the Lab Alley sheet says a dry, cool and well-ventilated place with the container tightly closed; the ICSC card says to keep it separated from incompatible materials. Sections 7 and 10 together give you the working rule: keep it dry and closed, and shelve it away from the oxidizers and chlorine-based materials named above. Lab Alley rates it as stable under normal conditions and lists no hazardous reactions under normal processing.

Disposal wording is deliberately general and differs by sheet. Sigma-Aldrich says to offer surplus and non-recyclable solutions to a licensed disposal company and to dispose of contaminated packaging as unused product, and also says not to let the product enter drains. Lab Alley says that chemical waste generators must determine whether a discarded chemical is classified as hazardous waste and must consult local, regional and national hazardous waste regulations. Neither sheet gives a numeric limit or a drain-disposal permission, so the decision belongs to your institution’s chemical hygiene plan and waste procedures. See the guide on the Hazard Communication Standard in laboratories for how SDSs fit into a written program.

On transport, the Lab Alley sheet reports urea as not regulated under DOT (US), IMDG and IATA.

Common misunderstandings

“Not classified” means no precautions

Classification is a threshold decision made from test data and criteria. A substance can fall below the threshold and still carry sensible handling statements: both supplier sheets say to avoid dust, and the ICSC card lists irritation to eyes, skin and the respiratory tract as short-term effects. Lab Alley’s sheet also states in section 15 that the product is a “Hazardous Chemical” as defined by the OSHA Hazard Communication Standard, even though it is not classified under it, which is a good example of how a sheet can read differently across sections.

Fertilizer urea, reagent urea and urea solutions share one sheet

They do not. The Lab Alley sheet lists fertilizer and chemical manufacture as identified uses of its granules, while the Sigma-Aldrich document covers a different catalogue item. A solution is a mixture, and mixtures are classified as mixtures: the PubChem note on impurities and additives is the general reason. Use the sheet issued for the exact product, grade and concentration in your hands. A related page, instant cold pack ingredients, covers urea in a consumer-product context.

The SDS and the ICSC card are the same thing

An ICSC is a standardized international card prepared by an international group of experts on behalf of ILO and WHO. It is a neutral hazard summary, not a supplier document, and carries no supplier-specific data. An SDS comes from the supplier of the actual product. Use the ICSC as a cross-check, and the supplier SDS for your inventory and compliance records.

The same oral LD50 means the same hazard profile

Both supplier sheets report an oral LD50 of 8,471 mg/kg in the rat, which is an acute toxicity figure and says nothing on its own about dust irritation, incompatibilities or decomposition products. Those come from other sections of the sheet.

A checklist for reading any urea SDS

  1. Section 1: confirm the product name, CAS 57-13-6, the grade and the supplier match the container in front of you.
  2. Section 2: note whether the sheet states a classification or “not hazardous”, and whether any label elements are listed.
  3. Section 7 and 10: note the storage conditions and every incompatible material named, including chlorine-based ones.
  4. Section 8: note whether an exposure limit is cited, and which PPE standards (EN 166, EN 374, 29 CFR 1910.133 and 1910.134) the sheet refers to.
  5. Section 9 and 5: note the melting point and decomposition temperature, if given, and the combustion products listed.
  6. Section 13: note what the sheet says about disposal and match it to your site’s waste procedures.
  7. Check the revision date, and record which sheet version you used.

Supplier SDSs are usually available from the manufacturer’s own site by catalogue number, from the supplier of the container, or through your institution’s SDS management system. The sheets used for this page were the Sigma-Aldrich (Fluka) urea 51458 sheet and the Lab Alley Urea Granules 99% Lab Grade sheet.

Sources

Data: Urea safety data compared across two supplier SDSs and the ILO/WHO ICSC 0595 card

Thirteen safety points for urea (CAS 57-13-6) compared side by side across the Sigma-Aldrich (Fluka) SDS 51458 rev. 2014, the Lab Alley Urea Granules 99% Lab Grade SDS rev. 2024 and ILO/WHO ICSC 0595 (1997). Each cell paraphrases or quotes what that document states; blank statements are shown as not stated.

Period covered: 1997/2024.

Urea safety data compared across two supplier SDSs and the ILO/WHO ICSC 0595 card
PointSigma-Aldrich (Fluka) SDS, rev. 2014Lab Alley SDS, rev. 2024ILO/WHO ICSC 0595
Hazard classificationNot a hazardous substance or mixture; no label elementsNot considered hazardous under 2012 OSHA HCS (29 CFR 1910.1200); no label elementsNo GHS classification shown on the card
Occupational exposure limitTWA 10 mg/m3 (USA WEEL)None established by regional regulatory bodiesNot stated
Oral LD50, rat8,471 mg/kg8,471 mg/kgNot stated
Skin and eye effectsNo skin irritation and no eye irritation (rabbit)No information availableIrritating to eyes, skin and respiratory tract
Eye protectionEquipment tested to NIOSH (US) or EN 166 (EU)Safety glasses or chemical goggles per 29 CFR 1910.133 or EN 166Safety spectacles
GlovesNitrile rubber, min. 0.11 mm, breakthrough 480 min (EN 374)Appropriate gloves and clothing; material not namedProtective gloves
Respiratory protectionNot required; N95 or P1 dust mask for nuisance dustApproved respirator if limits exceeded or symptoms occurLocal exhaust; prevent dispersion of dust
Incompatible materialsStrong oxidizing agentsStrong oxidizing agents, chlorine, sodium hypochloriteStrong oxidants, nitrites, inorganic chlorides, chlorites, perchlorates
DecompositionNo decomposition temperature given; fire products carbon oxides and NOxBegins at 180 C; NOx, CO, CO2, ammoniaDecomposes above melting point, giving toxic gases
StorageTightly closed, dry, well-ventilatedDry, cool, well-ventilated; tightly closedSeparated from incompatible materials
Melting point132 to 135 C132.5 to 134.5 C132.7 to 135 C
Water solubility480 g/l at 20 C590 g/l at 20 CMiscible
Disposal wordingLicensed disposal company for surplus; packaging as unused product; keep out of drainsWaste generator determines hazardous-waste status under local, regional and national rulesSweep spillage into covered containers, moisten first if appropriate

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Urea SDS: Hazards, GHS Classification, PPE and Storage

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →