Skip to main content
v2026.11,858 entries · CC-BY 4.0
LAC HealthMedical & Research SuppliesReagents, PPE & instruments — chain-of-custody documented.Fast, traceable sourcing built for regulated research environments, from bench consumables to instrumentation.Shop lac.us CodeCASRAIlac.us

Video Laryngoscope: Types, FDA Class and Evidence

A video laryngoscope adds a camera and screen to a rigid laryngoscope. Covers three blade designs, FDA Class 1 status and Cochrane 2022 results by design.

Written and maintained by CASRAI Editorial Board

Last updated

This page describes products and general use; it is not medical advice.

A video laryngoscope is a rigid laryngoscope with a camera at the blade tip and a screen, so airway staff and the people who stock airway equipment see the view the blade sees. This guide covers what the device is, the three blade designs that clinical trials group it into, how the US FDA classifies it, and what the largest trial review found by design. Who uses it: anesthesia and emergency airway teams, and the clinic, hospital and supply staff who specify and stock their equipment.

What a video laryngoscope is

In US regulation, a rigid laryngoscope is “a device used to examine and visualize a patient’s upper airway and aid placement of a tracheal tube” (21 CFR 868.5540, checked 2026-10-30). A video laryngoscope is a rigid laryngoscope that adds a camera and display to that purpose. For the conventional direct version, including its parts, see what a laryngoscope is.

How it is built

The common elements are a handle, a blade that carries the camera and light toward its tip, and a screen, either built into the handle or connected to it. Blades may be reusable or single-use. In one open-access cohort of 4,902 adults, the device studied (TD-C-IV, UE Medical) used single-use, disposable, non-channeled blades in sizes 3 and 4, with 42-degree angulation at the distal tip (BMC Anesthesiology 2025, PMC12649075, checked 2026-10-30). That is one example of one device, not a rule for the category.

Types and variants

The Cochrane review of videolaryngoscopy (Hansel et al., 2022, 222 studies, 26,149 adults) sorts video laryngoscopes into three design groups.

Design group What the source says
Macintosh-style Compared with direct laryngoscopy in 61 studies (9,883 participants)
Hyperangulated Compared with direct laryngoscopy in 96 studies (11,438 participants)
Channelled Compared with direct laryngoscopy in 73 studies (7,165 participants); results are in the evidence table below

Source: Hansel J et al., Cochrane Database of Systematic Reviews 2022, PMID 35373840 (abstract checked 2026-10-30).

US FDA classification and standards

  • Rigid laryngoscopes: product code CCW, Class 1 (general controls), 21 CFR 868.5540, 510(k) exempt, Anesthesiology panel (FDA Product Classification database, page updated 2026-10-26, checked 2026-10-30).
  • Recognized consensus standards listed by FDA for this code include ISO 7376 (third edition, 2020-08) for laryngoscopes for tracheal intubation, and ISO 7376-2 (first edition, 2025-09) for video laryngoscopes.
  • Related codes in openFDA: CAL, non-rigid (flexible) laryngoscope, Class 1, 21 CFR 868.5530; EQN, laryngoscope/nasopharyngoscope, Class 2, 21 CFR 874.4760, where reusable devices need validated reprocessing instructions and validation data in a 510(k) (openFDA classification API, checked 2026-10-30).

Evidence by design

These are population-level results from randomized trials in adults, not advice for any individual patient. Each figure compares video with direct laryngoscopy (risk ratio, 95% confidence interval, certainty as graded by the review).

Outcome Macintosh-style video Hyperangulated video Channelled video
Failed intubation RR 0.41 (0.26-0.65), moderate RR 0.51 (0.34-0.76), moderate RR 0.43 (0.30-0.61), moderate
Hypoxaemia RR 0.72 (0.52-0.99), moderate RR 0.49 (0.22-1.11), low; no clear difference RR 0.25 (0.12-0.50), moderate
Oesophageal intubation RR 0.51 (0.22-1.21), low RR 0.39 (0.18-0.81), moderate RR 0.54 (0.17-1.75), low
First-attempt success RR 1.05 (1.02-1.09), low RR 1.03 (1.00-1.05), low RR 1.10 (1.05-1.15), very low

For participants with a known or predicted difficult airway, the hyperangulated comparison for failed intubation gave RR 0.29 (0.17-0.48). The authors concluded that videolaryngoscopy likely provides a safer risk profile than direct laryngoscopy and that video laryngoscopes of all designs likely reduce failed intubation.

Cleaning, reprocessing and single-use blades

FDA’s classification text for the related EQN code states that reusable devices must come with validated reprocessing instructions and validation data. Follow the manufacturer’s instructions for use for each device. For the general framework, see the Spaulding classification and high-level disinfection and sterilization technology.

Common mistakes

  • Treating all video laryngoscopes as one design: the Cochrane results differ by outcome between Macintosh-style and hyperangulated groups.
  • Assuming blades interchange across brands. Blade sizes and angulation are device-specific; the 42-degree, size 3 and 4 figures above describe one device only. For conventional blade sizing see Macintosh blade sizes.
  • Reading trial risk ratios as guarantees for an individual patient or a particular device.

FAQ

What is the difference between direct and video laryngoscopy?

Direct laryngoscopy relies on a line of sight down the blade; video laryngoscopy shows the view on a screen from a camera on the blade. In the 2022 Cochrane review, videolaryngoscopy likely reduced failed intubation compared with direct laryngoscopy (moderate certainty).

Is a video laryngoscope an FDA-regulated device?

Rigid laryngoscopes are Class 1 under 21 CFR 868.5540, exempt from 510(k) premarket notification subject to the limitations in 21 CFR 868.9 (checked 2026-10-30).

Related supplies are listed under emergency and trauma supplies.

Sources

Dates are the day each source was checked.

  • 21 CFR 868.5540, Cornell LII, https://www.law.cornell.edu/cfr/text/21/868.5540 (checked 2026-10-30)
  • FDA Product Classification, code CCW, https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?id=CCW (checked 2026-10-30)
  • openFDA device classification API, https://api.fda.gov/device/classification.json (checked 2026-10-30)
  • Hansel J et al., Cochrane Database Syst Rev 2022, https://pubmed.ncbi.nlm.nih.gov/35373840/ (checked 2026-10-30)
  • BMC Anesthesiology 2025, https://pmc.ncbi.nlm.nih.gov/articles/PMC12649075/ (checked 2026-10-30)

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Video Laryngoscope: Types, FDA Class and Evidence

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →