Visual Reinforcement Audiometry: How VRA Works, Age Range and Equipment

Visual reinforcement audiometry (VRA) tests infant hearing with a rewarded head turn. See the age range, the equipment it uses and its limits.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Visual reinforcement audiometry (VRA) is a behavioral hearing test for infants and toddlers in which a child learns that turning toward a sound is rewarded by a visual display, such as a lit toy or a screen image. It finds the quietest level at which the child reliably responds at each tested frequency. Interacoustics, a hearing-equipment manufacturer, describes it as best suited to infants from about six months to around two and a half years of age; the Children’s Health pediatric service describes it for children from 6 months to around 2 to 3 years.

General information for clinic and laboratory staff. This page is not medical advice and does not describe how to carry out a test on a patient.

Definition and scope

VRA is a behavioral test: it relies on an observable response (a head turn) rather than on a physiological recording. Interacoustics, a hearing-equipment manufacturer, describes the aim as finding the minimum response level at each frequency, and says the child turns toward a visual reinforcer, a toy or a screen image, on hearing a sound (Interacoustics Academy). Children’s Health describes the same approach on its service page, adding that it measures sensitivity across frequencies in each ear so that an audiogram can be plotted.

The two organizations give slightly different age ranges, so the age is best read as an approximate range rather than a single cut-off:

  • Interacoustics: infants from six months to around two and a half years.
  • Children’s Health: roughly 6 months to around 2 to 3 years.

How VRA works in principle

The Interacoustics guide describes the principle in three parts: conditioning, response checking and a response criterion. This page covers the concept only and is not a test protocol.

  • Conditioning. The child learns to link a sound with the appearance of the visual reinforcer.
  • Checking the response. Trials without a sound (“no-sound” trials) help show whether head turns are caused by the sound or happen on their own.
  • Criterion. The result is recorded as a minimum response level, based on how consistently the child responds.

Pure tones are not used in the free field because of standing waves, so other stimuli are presented through loudspeakers (Interacoustics).

What equipment a VRA setup uses

A laboratory or clinic that equips a pediatric test room needs to know which hardware a VRA setup involves. The table lists the components described by Interacoustics and Children’s Health.

Component What the source says Source
Audiometer Children’s Health describes an audiometer modified for young children. Children’s Health
Loudspeakers (sound field) Placed about 1 m from the child at 90 degrees azimuth. Interacoustics
Visual reinforcers Toys behind smoked Perspex, or screen-based reinforcers, placed near the speaker and in line with the child’s head. Children’s Health mentions video animations and toys in boxes, lighted toys 90 degrees to each side. Interacoustics; Children’s Health
Earphones Headphones or insert earphones once the child tolerates them; Children’s Health mentions foam tips or custom ear molds. Interacoustics; Children’s Health
Bone-conduction transducer Used once tolerated; not ear-specific. Interacoustics

What each transducer can and cannot tell you

The transducer determines whether a result can be assigned to one ear. The comparison below follows the Interacoustics guide.

Transducer Ear-specific? Note from the source
Loudspeakers (sound field) No Results reflect the better ear.
Headphones or insert earphones Yes Needed for ear-specific results.
Bone conduction No Masking is needed.

Where it matters for labs, clinics and supply decisions

Equipment that produces test tones is a regulated medical device. Under 21 CFR 874.1050, an audiometer is defined as an electroacoustic device that produces controlled levels of test tones and signals, intended for diagnostic hearing evaluations and to aid diagnosis of possible otologic disorders, and the definition includes automated audiometers. The regulation classifies audiometers as Class II and exempts them from 510(k) premarket notification, subject to the limitations in 21 CFR 874.9, with an exception for the otoacoustic emission device; the text also refers to ANSI S3.6-1996, “Specification for Audiometers” (Cornell Legal Information Institute copy of the CFR).

For a broader look at audiometer categories, see audiometer types. For the wider list of items an audiology clinic stocks, see the audiology clinic supply checklist. For how the exemption and classification system works, see the guide to FDA medical device classification, 510(k) and PMA pathways and the explanation of the 510(k) premarket notification.

Common misunderstandings

  • “VRA gives a true threshold.” The Interacoustics guide says “minimum response level” is the more appropriate term for VRA than “threshold”.
  • “Sound-field VRA tests each ear.” It does not; sound-field results reflect the better ear.
  • “Any head turn counts.” Head turns are subjective, which is why no-sound trials are used. The same guide lists parental cueing, short attention span and intolerance of transducers as limits.
  • “The age range is fixed.” Sources differ (about 2, 2.5 or 3 years as the upper end), so treat the range as approximate.

Frequently asked questions

Is VRA a physiological test?

No. VRA is behavioral: it depends on an observable response (a head turn) to a sound, rather than on a physiological recording.

What age is visual reinforcement audiometry for?

Interacoustics describes it as best suited to infants from six months to around two and a half years; Children’s Health describes children aged 6 months to around 2 to 3 years.

Is VRA ear-specific?

Only when headphones or insert earphones are used. Sound-field results reflect the better ear, and bone-conduction results are not ear-specific without masking.

Is an audiometer regulated by the FDA?

Yes. 21 CFR 874.1050 classifies audiometers as Class II devices, with an exemption from 510(k) subject to 21 CFR 874.9 and an exception for the otoacoustic emission device.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Visual Reinforcement Audiometry: How VRA Works, Age Range and Equipment

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →