Skip to main content
v2026.11,986 entries · CC-BY 4.0

Western Blot Stripping Buffer: Mild vs Stringent Recipes

Mild glycine-SDS and stringent Tris-SDS/2-mercaptoethanol stripping buffers for western blot reprobing, with published times and how to verify removal.

Written and maintained by CASRAI Editorial Board

Published

On this page

A western blot stripping buffer is a solution that removes bound primary and secondary antibodies from a blotted membrane so the same membrane can be probed again for a different protein. Two families are in routine use: a mild, low-pH glycine-SDS buffer, and a stringent, heated Tris-SDS buffer containing 2-mercaptoethanol. Start mild, escalate only if a secondary-only test still shows signal, and expect some protein loss on every round.

What stripping and reprobing mean

Stripping takes antibodies off a membrane without removing the transferred proteins. Reprobing then applies new primary and secondary antibodies to the same membrane. The aim is to detect several targets, for example a protein of interest and a loading control, from one transfer instead of running and transferring a second gel. The basic detection sequence this builds on is in Western Blot Protocol Basics; stripping is the optional last step of that sequence.

Both manufacturers’ guidance read for this page makes the same point: no stripping method is guaranteed to work for every antibody-antigen pair, and some of the target protein is lost each time a membrane is stripped. Thermo Fisher Scientific notes that antigen loss should be expected, and the Addgene guide notes that sample is lost on each round and that some groups report up to ten cycles.

Mild stripping buffer (low pH glycine-SDS)

The mild buffer works by acidifying the membrane environment with glycine and detergent so antibody binding is disrupted. Thermo Fisher gives this recipe: 15 g glycine, 1 g SDS and 10 mL Tween 20 in 800 mL of water, adjusted to pH 2.2 with HCl, then brought to 1,000 mL with water.

Addgene describes the same buffer as a range rather than a single recipe: glycine or glycine-HCl at 25 to 200 mM, SDS at 0.1 to 1% w/v, optional Tween 20 at 1% v/v, and HCl to reach pH 2.0 to 2.2. Leaving out Tween 20 gives the mildest version.

Mild protocol as published

  • Rinse the membrane in water (Thermo Fisher).
  • Incubate with agitation at room temperature for 10 to 20 minutes (Thermo Fisher) or 5 to 30 minutes (Addgene).
  • For high-affinity or saturated blots, both sources allow an extra 5 to 10 minutes at 37 °C.
  • Wash in TBST or PBST: three washes of 5 minutes (Thermo Fisher), or two to three washes of 5 to 10 minutes (Addgene).
  • Reblock before applying the next primary antibody.

Stringent stripping buffer (Tris-SDS with 2-mercaptoethanol)

The stringent buffer combines SDS, a reducing agent and heat, and is the usual escalation when the mild buffer leaves bands behind. Thermo Fisher gives: 12.5 mL of 0.5 M Tris-HCl pH 6.8, 20 mL of 10% SDS, 0.8 mL of 2-mercaptoethanol and 67.5 mL of water. Make it just before use and work in a fume hood, since 2-mercaptoethanol is volatile and toxic.

Addgene expresses the same chemistry as Tris-HCl at 62.5 mM, SDS at 2% w/v and beta-mercaptoethanol at 100 to 115 mM (about 0.7 to 0.8% v/v), at pH 6.7 to 6.8. Addgene stresses adding the beta-mercaptoethanol fresh because it oxidises.

Stringent protocol as published

  • Incubate with gentle agitation at 50 °C: 30 minutes (Thermo Fisher) or 30 to 45 minutes (Addgene).
  • Wash thoroughly in TBST: six washes of 5 minutes (Thermo Fisher), or two to six washes of 5 to 10 minutes (Addgene). Addgene points out that beta-mercaptoethanol can react with antibodies, so thorough washing matters.
  • Reblock before reprobing.

The data table below sets the two sources’ recipes and timings side by side.

How to confirm the membrane is actually stripped

Do not assume a stripped membrane is clean. Thermo Fisher’s test is to wash and block the membrane, incubate with the secondary antibody only, add substrate and image. No signal means the primary antibody has been removed. If bands remain, increase the incubation time or temperature, or change method.

Addgene describes a two-step check. First re-image the membrane to look for residual signal from the old secondary antibody. Then reblock and apply the secondary antibody alone to look for residual primary antibody. A blank result is the goal. Skipping this check is how ghost bands from the first probe get mistaken for the second target.

Planning checklist before you strip

  • Membrane type. Thermo Fisher recommends PVDF for blots that will be stripped, with a quoted binding capacity of 170 to 200 µg/cm², and describes it as less brittle and fragile than nitrocellulose. Addgene says nitrocellulose can be stripped too, but advises the mild buffer to limit loss.
  • Detection chemistry. Only chemiluminescent or fluorescent blots are suitable. Thermo Fisher notes that a chromogenic stain is permanent and cannot be stripped. Avoid avidin or streptavidin-biotin probes before stripping.
  • Order of targets. Addgene advises probing the least abundant target first; if abundances are similar, use the weaker-binding antibody first. Thermo Fisher likewise advises probing the low-abundance or low-affinity antibody first, because antigen is lost on stripping.
  • Do not let the membrane dry with antibodies on it if you plan to reprobe: Addgene reports that dried antibody sticks permanently.
  • Rewetting. Addgene notes that dried PVDF must be rewet with methanol, while nitrocellulose can go straight into buffer.
  • Do not compare band intensity between rounds. Addgene cautions against comparing band strength across probing rounds, because loss from stripping differs by target. For quantitation and normalisation across targets, see Western Blot Loading Control and Normalization.

A sequence for escalating from mild to stringent

Combining the two published workflows gives a decision order that is easy to follow at the bench. This is an editorial synthesis of the sources, not a separate protocol from either one.

  1. Confirm the blot is on PVDF (or nitrocellulose with the mild buffer) and was developed with chemiluminescent or fluorescent detection.
  2. Strip with the mild buffer at room temperature for the shorter published time, then wash.
  3. Reblock, apply secondary antibody only, add substrate and image. If the membrane is blank, proceed to the next primary antibody.
  4. If signal remains, repeat the mild buffer with the added 5 to 10 minutes at 37 °C, which both sources allow for high-affinity or saturated blots, and test again.
  5. Only if bands persist, switch to the stringent buffer at 50 °C in a fume hood, wash thoroughly, reblock and test again.

Each step trades antibody removal against protein loss, which is the reason the sources advise ordering targets from least abundant to most abundant before you start.

Stripping buffers are separate from the buffers used earlier in the workflow. Transfer conditions are covered in Western Blot Transfer Buffer, and the choice of blocker, which you must repeat after every strip, in Western Blot Blocking Buffer: BSA or Milk. Ready-made stripping reagents also exist: Addgene lists premade kits from Thermo Fisher, MilliporeSigma and Azure, and notes that recipes are also published by Bio-Techne, Thermo Fisher and MilliporeSigma. Differences in concentration between these published recipes are normal; follow one source’s recipe consistently.

Common misunderstandings

  • “Stripping is a free second blot.” It is not. Both sources describe loss of protein and antigen with every round.
  • “Harsher is always safer for a clean membrane.” The stringent buffer removes more antibody but also more sample; Addgene and Thermo Fisher both present mild first, stringent as escalation.
  • “A weaker second band means less protein.” Not necessarily, since stripping loss differs between rounds and targets.
  • “Any membrane and any detection works.” Chromogenic detection cannot be stripped, and biotin-based probes should be avoided.
  • “The stringent buffer is just a stronger mild buffer.” It uses a different mechanism (reduction plus heat at near-neutral pH) and carries a hazard the mild buffer does not: 2-mercaptoethanol must be handled in a fume hood.

Frequently asked questions

How many times can a western blot membrane be stripped?

There is no fixed number. Addgene notes that some researchers report up to ten cycles, but sample is lost every round, so the practical limit depends on how abundant the targets are and how well the antibodies bind.

Can nitrocellulose be stripped?

Yes, but PVDF is preferred. Thermo Fisher recommends PVDF, and Addgene advises using the mild buffer on nitrocellulose to limit protein loss.

Can a chromogenic western blot be stripped?

No. Thermo Fisher states that chromogenic stains are permanent, so stripping and reprobing is for chemiluminescent or fluorescent detection.

Should I use the mild or stringent stripping buffer first?

Use the mild buffer first. Move to the stringent buffer only if a secondary-antibody-only test after reblocking still shows signal.

Why does the stringent buffer need a fume hood?

Both sources identify 2-mercaptoethanol as the issue: Thermo Fisher specifies a fume hood, and Addgene describes beta-mercaptoethanol as volatile and toxic. Add it fresh, since it oxidises.

Does stripping remove the transferred protein?

Some, yes. Stripping is designed to remove antibodies, but both sources report some loss of target protein with each round, which is why low-abundance targets should be probed first.

Sources

Data: Published mild and stringent western blot stripping conditions: Thermo Fisher vs Addgene

Side-by-side comparison of the mild and stringent membrane stripping buffers and incubation conditions published by Thermo Fisher Scientific (Pierce methods page) and the Addgene blog, compiled from the two pages' own recipes and ranges.

Published mild and stringent western blot stripping conditions: Thermo Fisher vs Addgene
Buffer and parameterThermo FisherAddgene
Mild: glycine15 g per 1,000 mL25-200 mM (glycine or glycine-HCl)
Mild: SDS1 g per 1,000 mL0.1-1% w/v
Mild: Tween 2010 mL per 1,000 mLOptional, 1% v/v; omit for mildest
Mild: pH2.2 (HCl)2.0-2.2 (HCl)
Mild: room-temperature incubation10-20 min5-30 min
Mild: optional extra at 37 C5-10 min for high-affinity or saturated blots5-10 min
Mild: washes3 x 5 min TBST/PBST2-3 x 5-10 min
Stringent: Tris12.5 mL of 0.5 M Tris-HCl pH 6.8 per 100 mL62.5 mM Tris-HCl, pH 6.7-6.8
Stringent: SDS20 mL of 10% SDS per 100 mL2% w/v
Stringent: 2-mercaptoethanol0.8 mL per 100 mL100-115 mM (0.7-0.8% v/v)
Stringent: incubation at 50 C30 min30-45 min
Stringent: washes6 x 5 min TBST2-6 x 5-10 min

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Western Blot Stripping Buffer: Mild vs Stringent Recipes

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →