Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
Who uses it: ophthalmic surgical teams, sterile processing and theatre staff, and the buyers and managers who keep instrument sets complete. After reading, you should be able to say what a cataract instrument tray holds, which parts sit outside the tray, how FDA classifies the hand instruments versus the phacoemulsification system, and what the published evidence says about keeping sets complete.
What cataract surgery instruments are
Cataract surgery instruments are the handheld tools and the powered system used in surgery to remove a clouded lens. Most of the hand tools fall under the FDA category “manual ophthalmic surgical instrument”: a nonpowered, handheld device intended to aid or perform ophthalmic surgical procedures (21 CFR 886.4350). The powered phacoemulsification system is a separate device type. An eye surgery instrument set is the broader family; a cataract instrument tray is the subset arranged for this one operation.
What a cataract tray holds, and what stays outside it
A cataract surgery tray, in the words of the University of Iowa’s EyeRounds tutorial, “contains all instruments needed for cataract surgery including the I/A hand piece.” The instruments are taken from the tray and laid on the utility table in the order they will be used. The phaco machine is not part of the tray: the phaco tubing and accessory kit is a separate single-use pack that includes a plastic drape for the utility tray and a cassette with tubing for irrigation and aspiration, and the phaco handpiece connects to the machine.
There is no single standard tray. Surgeons’ own lists differ, as the next section shows. Backup instruments are often kept outside the main tray, in sealed peel-packs, for use only if a complication arises.
Types and FDA class
| Type | What the regulation says | FDA class | Key difference |
|---|---|---|---|
| Manual ophthalmic surgical instrument (21 CFR 886.4350) | A nonpowered, handheld device intended to aid or perform ophthalmic surgical procedures; examples named in the regulation include the ophthalmic caliper, cystotome and eyelid clamp | Class I (general controls); exempt from 510(k), subject to the limitations in 21 CFR 886.9 | No power source; reusable hand tools |
| Phacofragmentation system (21 CFR 886.4670) | An AC-powered device with a fragmenting needle, intended for use in cataract surgery to disrupt a cataract with ultrasound and extract it | Class II | Powered system with its own regulation |
The practical reading: forceps, cystotomes and calipers are regulated as manual instruments, while the phaco system is a distinct powered device. Individual products can still carry their own classification, so the product record is the authority for any specific item. For single-instrument detail, see cystotome, Utrata forceps and eyelid speculum; for the wider category, see ophthalmic surgical instruments.
Example trays from three surgeons
A 2004 article in Ophthalmology Management surveyed three surgeons (Black, Graham and Shingleton) about their cataract trays. The entries below are the items the article names; the counts are the number of main-tray entries each surgeon reported. This is surgeon-reported and dated, so it shows variation rather than a standard.
| Surgeon | Main-tray entries | Items named in the article | Kept outside the main tray |
|---|---|---|---|
| Black | 14 | Phaco handpiece, I/A handpiece, chopper, two lens injectors, hydroexpression cannula | Needle holders, tying forceps and vitrectomy sets in peel-packs for complications |
| Graham | 18 | 3-mm diamond keratome, Grayson nucleus manipulator, Conner wand; “2 McPherson tying forceps” counted as one entry | An extra tray in a prep room |
| Shingleton | 10 | Sharpoint 2.85 clear cornea steel keratome, Wiles hydrodissection cannula | Not stated in the article |
The surgeons explain their choices differently. Black: “we remove any instruments not used in every case.” Shingleton: “We systematize our procedures so that we can use the smallest number of instruments possible.” Graham: “Our tools are selected to accommodate several surgeons.” Each reported using about four trays across two operating rooms, at roughly five to six cases an hour.
How sets are specified and kept complete
A 2011 survey in Community Eye Health (Patel and Hoare) covered 85 eye units, 43 in South-East Asia and 32 in Africa, 83 of them in low- and middle-income settings. It looked at 41 instruments in four groups: scissors, forceps, knives and cannulae. Most procedures in the survey were small-incision (60%) or extracapsular (24%); phacoemulsification was 5%, so the findings reflect mainly manual-technique units.
- Incomplete sets were common: 48% of units had at least one incomplete cataract set (59% of low-volume units, 28% of high-volume units). Effects reported were longer operations (46%) and fewer operations (12%). 40% of units had instruments unusable for over a year.
- Most failures were preventable: poor handling, rust and bluntness accounted for 73% of unusable instruments. Forceps were mostly broken, cannulae faulty, knives blunt, and scissors blunt or broken.
- Set numbers: the authors state that, ideally, there should be three complete cataract sets for every theatre bed in use: one in use, one being prepared and one being sterilised.
- Responsibility: the authors advise assigning one person to manage the daily care and long-term maintenance of instruments.
These are one survey’s recommendations from 2011 in resource-limited units, not a regulatory requirement. For the consumables that surround a surgical session, see the ophthalmology surgery center supply checklist.
Safe use and handling basics
The same survey gives these general care rules: clean and lubricate instruments after each operation to prevent rust; rinse with distilled, pH-neutral water; and inspect regularly, ideally with magnification (only 29% of units did so). The authors note that if instruments are not available, are blunt or do not function properly, surgery may have to be delayed or postponed. Follow the manufacturer’s instructions for use for cleaning and sterilisation of each specific instrument. For the operating microscope used alongside the tray, see surgical microscope.
Common mistakes
- Treating one surgeon’s tray as a standard. The three trays above range from 10 to 18 main-tray entries.
- Assuming the phaco handpiece, tubing and cassette belong to the instrument tray. They belong to the machine and its single-use kit.
- Skipping routine inspection: preventable causes made up 73% of unusable instruments in the survey.
- Planning with too few sets, which the survey links to delayed or reduced surgery.
FAQ
What is a cataract instrument tray?
It is the tray holding the instruments needed for cataract surgery, including the I/A handpiece, arranged for use in order. The phaco machine and its single-use tubing kit are separate. Contents vary by surgeon.
What is the difference between eye surgery instruments and cataract surgery instruments?
Eye surgery instruments cover every ophthalmic operation, and the FDA groups the hand tools as manual ophthalmic surgical instruments (Class I). Cataract surgery instruments are the subset used for that operation, plus the Class II phacofragmentation system when phacoemulsification is used.
Are cataract surgery instruments regulated by the FDA?
Yes. Manual instruments are Class I and exempt from 510(k) subject to 21 CFR 886.9 limitations; the phacofragmentation system is Class II.
Sources
- 21 CFR 886.4350, Manual ophthalmic surgical instrument, Legal Information Institute, law.cornell.edu/cfr/text/21/886.4350, checked 2026-11-01.
- 21 CFR 886.4670, Phacofragmentation system, law.cornell.edu/cfr/text/21/886.4670, checked 2026-11-01.
- Tran C, Quist TS, Fitzgerald K, Shiner J, Bloomberg J. Phacoemulsification: How do I set up and take down the phaco machine? EyeRounds.org, University of Iowa, 8 Dec 2020, eyerounds.org, checked 2026-11-01.
- Kent C. Making the Most of Your Cataract Surgical Tray. Ophthalmology Management, 1 May 2004, ophthalmologymanagement.com, checked 2026-11-01.
- Patel D, Hoare P. Instruments for cataract surgery: results from our survey. Community Eye Health 2011;24(76):26-29, PMC3284751, checked 2026-11-01.







