Written and maintained by CASRAI Editorial Board
Published · Last updated
This page describes products and general use; it is not medical advice.
On this page
A dialysis clamp is any device that closes off tubing in a hemodialysis blood circuit so flow stops. Three kinds appear in practice: manual clamps built into the bloodline set, clamps built into the dialysis machine, and automatic tension clamps sold as a separate accessory. Dialysis clinic staff, equipment evaluators and students use the term for all three, which is why the regulatory status and the instructions for use differ from one clamp to the next.
What dialysis clamps are
In hemodialysis, blood leaves the patient through an arterial line, passes the dialyzer and returns through a venous line. Clamps on that circuit stop flow at chosen points, such as the patient ends, access sites and pressure-monitor lines. For the full set of parts they sit on, see blood tubing; for the equipment that drives the circuit, see the dialysis machine guide.
Who uses them: dialysis nurses and technicians who work with the circuit, and the clinic or home-program staff responsible for bloodline sets and accessories.
Types of dialysis clamps
| Type | Where it sits | Key difference | Source |
|---|---|---|---|
| Bloodline set clamps | On the tubing of the disposable blood tubing set | Used completely open or completely closed; not intended to regulate the flow of fluids | Fresenius Medical Care hemodialysis blood tubing set instructions for use |
| Machine clamps | On the dialysis machine, acting on the tubing (the same instructions refer to the machine’s venous occlusion clamp and its air detector clamp) | Part of the machine, so covered by the machine’s own instructions, not supplied with the tubing set | Same instructions for use |
| Automatic tension clamp | Accessory mounted on an assembled blood circuit | Clamps blood flow automatically when tension in the venous access line passes a preset threshold | FDA 510(k) K093915, DEKA TAC Device, decision 23 August 2011 |
How FDA identifies automatic dialysis clamps
FDA lists automatic blood-tubing clamps under product code FIG, named “Clamp, Tubing, Blood, Automatic”, device class 2, regulation number 876.5820 (openFDA device classification). That regulation, 21 CFR 876.5820, covers the hemodialysis system and accessories and treats accessories directly associated with the extracorporeal blood system as Class II. The regulation text does not mention clamps by name, so the product code, not the regulation text, is what identifies a clamp.
The FDA 510(k) summary for the DEKA TAC Device describes a passive, spring-based mechanism that needs no external power, intended for use in clinical facilities. Its comparison table lists a response time of less than 0.5 seconds. The performance evidence described is bench testing (actuation force, clamp effectiveness and closed-clamp leak rate), with no clinical data. The FDA database record is the primary reference for the device.
Safe handling basics
- Follow the instructions for use of the specific bloodline set and machine. The Fresenius Medical Care instructions state that all blood tubing set clamps must be used either completely open or completely closed and are not intended to regulate the flow of fluids.
- The same instructions warn against kinks in the bloodline, particularly in the post-pump arterial segment, because significant hemolysis of red blood cells can occur in kinked blood tubing. A kink is not a substitute for a clamp.
What to verify when evaluating a clamp
Only criteria drawn from the sources below are listed.
- Is the clamp integral to the bloodline set, built into the machine, or a separate accessory? Only the separate accessory is likely to carry its own FDA clearance.
- For an accessory, ask the supplier for its instructions for use and its 510(k) number, and check the number in FDA’s 510(k) database. The product code for automatic tubing clamps is FIG.
- Read what evidence the clearance rests on. For K093915 the described testing was bench testing.
- Match the accessory to the bloodline set and machine named in the instructions for use.
For wider equipment lists, see the outpatient dialysis center supply checklist, and for vascular access, the hemodialysis catheter guide.
Common mistakes
- Using a set clamp to throttle flow, which the instructions say it is not intended for.
- Assuming every clamp is a regulated accessory; bloodline clamps are part of the set and machine clamps are part of the machine.
- Treating a Class II product code as proof of clinical performance; the K093915 summary describes bench testing only.
FAQ
What is a dialysis clamp?
A device that closes off tubing in a hemodialysis blood circuit so flow stops. It may be part of the bloodline set, part of the machine, or a separate accessory.
What is an automatic tension clamp?
An accessory that clamps blood flow automatically when tension in the venous access line exceeds a preset threshold. FDA cleared the DEKA TAC Device (K093915) in 2011 as a passive spring-based device that needs no external power.
Can a bloodline clamp be used to regulate flow?
No. The Fresenius Medical Care instructions state that blood tubing set clamps must be used completely open or completely closed and are not intended to regulate the flow of fluids.
Are dialysis clamps regulated by FDA?
Automatic blood-tubing clamps have FDA product code FIG, device class 2, under regulation 876.5820. Clamps that are part of a bloodline set or a machine are covered with that set or machine.
Sources
All sources checked 1 November 2026.
- FDA 510(k) database, K093915 (DEKA TAC Device): https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K093915
- openFDA device classification, product code FIG: https://api.fda.gov/device/classification.json?search=product_code:FIG
- 21 CFR 876.5820, Hemodialysis system and accessories: https://www.law.cornell.edu/cfr/text/21/876.5820
- Fresenius Medical Care North America, CombiSet hemodialysis blood tubing set instructions for use: https://freseniusmedicalcare.com/content/dam/fmcna/live/support/documents/instructions-for-use/bloodlines—ifus/G71-4582%20-%20CombiSet%20SMARTECH.pdf