Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop vessel loops supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

What Are Vessel Loops? Uses, Material and FDA Class

Vessel loops are sterile single-use surgical cords. See how FDA and GUDID list them (KDC, HCF, Class 1) and what a record tells you.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

Vessel loops are single-use, sterile, nonimplantable cords that surgical teams use to identify, retract and occlude blood vessels, tendons and nerves. A vessel loop (also written vessel loops in the plural) is a disposable surgical accessory, not a reusable instrument. Clinic staff, operating-room buyers and students use this page to read a product listing correctly.

What is a vessel loop?

In the NLM AccessGUDID database, both device records below carry the GMDN term “Surgical vessel loop”, defined as a nonimplantable cord intended to be used during a surgical procedure to assist a surgeon to identify, retract and occlude blood vessels, tendons and nerves. The definition adds that it is constructed of synthetic polymer, is typically coloured to facilitate visualization, and is a single-use device. One manufacturer record (Richard-Allan Vessel Loop, model 3912) states the labeled intended use as occluding, retracting and identifying arteries, veins, tendons and nerves in surgical procedures.

Who uses it: surgical teams; the people who stock, count and reorder them are clinic and hospital supply staff.

How a vessel loop is built

The GUDID definition describes a cord made of a synthetic polymer, usually coloured so it is easy to see. Both records below list the material only as a synthetic polymer, so a product name alone does not tell you the specific material; check the manufacturer’s labeling.

Types and how FDA lists them

FDA does not have one product code for every vessel loop. The two example records below sit under different codes, both in 21 CFR 878.4800 and both Class 1 in FDA’s classification database.

Listing FDA product code and name Regulation and class Packaging and use (from GUDID)
Richard-Allan Vessel Loop (model 3912) KDC, Instrument, Surgical, Disposable 21 CFR 878.4800, Class 1 Single-use; packaged sterile
Vascular Silicone Ties (VST Mini Blue) HCF, Instrument, Ligature Passing And Knot Tying 21 CFR 878.4800, Class 1 Single-use; sterile

Because the code differs by maker, do not assume that every vessel loop is listed the same way. Check the product code on the specific device record.

Sizes and specifications that are documented

Product Size in the record
Vascular Silicone Ties, VST Mini Blue 0.075 in x 18 in (0.2 cm x 46 cm)

The Richard-Allan record lists no sizes.

What the label and record tell you

The GUDID record is where a buyer or student can confirm the facts that matter for handling and receiving. For the Richard-Allan record, GUDID shows that the device is packaged sterile, that sterilization before use is not required, that it is for single use, that the labeling contains no MRI safety information, and that it is not required to be labeled as containing natural rubber latex under 21 CFR 801.437. The Vascular Silicone Ties record also states “not made with natural rubber latex” and lists the storage conditions keep dry, ambient temperature and away from sunlight. Read those fields on the record for the exact product you are handling, because they are set per device.

Safe use and handling basics

  • Single-use means the device is not intended to be reused; GUDID flags this per device.
  • Packaged-sterile products come with the manufacturer’s own instructions for use; follow the labeling for the product in hand.
  • Questions about use on a patient belong to the surgeon and the facility’s clinical protocols, not to a product page.

Common mistakes when reading a listing

  • Assuming all vessel loops share one FDA product code. The two records above differ (KDC and HCF).
  • Assuming the material from the product name. GUDID gives only “synthetic polymer” for the example records.
  • Assuming a sterile single-use cord is a general-purpose tie or tape; the GUDID definition ties it to surgical procedures.

Frequently asked questions

What are vessel loops used for?

Per the GUDID definition, to assist a surgeon to identify, retract and occlude blood vessels, tendons and nerves during a surgical procedure.

Are vessel loops reusable?

The GUDID definition and both example records state that vessel loops are single-use devices.

What FDA class is a vessel loop?

The two example records are Class 1 under 21 CFR 878.4800, listed under product code KDC or HCF depending on the maker. Class can differ for other products, so confirm it on the specific listing.

Is a vessel loop the same as a hemostat?

No. A vessel loop is a disposable cord; a hemostat is a clamp. See our guide to what a hemostat is.

For other surgical instruments see the Richardson retractor and Deaver retractor guides, and for sterile practice see aseptic technique. Handheld clamping instruments are carried in the supplier category for forceps.

Sources

  • NLM AccessGUDID, Richard-Allan Vessel Loop, device 00840113221837: https://accessgudid.nlm.nih.gov/devices/00840113221837 (checked 2026-10-30)
  • NLM AccessGUDID, Vascular Silicone Ties, device 00690521023208: https://accessgudid.nlm.nih.gov/devices/00690521023208 (checked 2026-10-30)
  • FDA product classification database (openFDA), product codes KDC and HCF: https://api.fda.gov/device/classification.json?search=product_code:KDC and https://api.fda.gov/device/classification.json?search=product_code:HCF (checked 2026-10-30)

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Are Vessel Loops? Uses, Material and FDA Class

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →