Bed Scale: Types, FDA Class I and Zeroing Rules

A bed scale weighs a patient who cannot stand. See the FDA Class I rule (21 CFR 880.2720), the three designs it covers and the zero and hold steps.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

A bed scale is a patient scale built into, or placed under, a bed so a person who cannot stand on a scale can be weighed lying in it. Its users are nurses, care staff, biomedical engineers and buyers who need to know what the device is, how US regulators classify it, and which handling rules the manufacturers themselves publish. A chair scale works on the same principle and falls under the same FDA regulation.

What a bed scale is

US federal regulation does not use the phrase “bed scale”; it defines a patient scale as “a device intended for medical purposes that is used to measure the weight of a patient who cannot stand on a scale” (21 CFR 880.2720, checked 2026-11-01). The definition includes “devices placed under a bed or chair to weigh both the support and the patient”. The weight of the bed or chair, and anything on it, is therefore part of what the device measures, which is why the handling rules below focus on zeroing and on what is on the bed.

The regulation allows a patient scale to be mechanical, battery powered or AC powered, and to include transducers, signal amplification, conditioning and display equipment.

Types of patient scale covered by the same regulation

21 CFR 880.2720 names three designs. Bed and chair scales are the first; the other two are listed because they share the same regulatory entry.

Design (as the regulation words it) How the patient is weighed Source
Devices placed under a bed or chair Weigh both the support (bed or chair) and the patient 21 CFR 880.2720
Sling devices The patient is lifted by a sling from a bed to be weighed 21 CFR 880.2720
Platform devices The patient is placed on the scale platform to be weighed 21 CFR 880.2720

Some beds carry a scale in the frame. Agiliti’s Bari Classic bed quick reference guide, for example, describes a built-in scale meter on the bed (checked 2026-11-01). For the bed itself, see what a hospital bed is, hospital bed parts and bariatric beds.

How the FDA classifies it

Under 21 CFR 880.2720(b), a patient scale is Class I (general controls) and is exempt from the premarket notification procedures in subpart E of part 807, subject to the limitations in 21 CFR 880.9. The openFDA classification database lists “Scale, Patient” as class 1, product code FRW, regulation 880.2720, in the General Hospital panel (checked 2026-11-01). Two nearby entries are classified separately:

FDA device name Product code Regulation Class
Scale, Patient (includes under-bed and under-chair scales) FRW 21 CFR 880.2720 1
Scale, Stand-On, Patient FRI 21 CFR 880.2700 1
Scale, Platform, Wheelchair INF 21 CFR 890.3940 1

So a scale for a patient who cannot stand sits under a different regulation from a stand-on scale, and a wheelchair platform scale is classified under the physical medicine regulations. For the wheelchair case, see wheelchair scale types and standards.

Is a chair scale a bed scale?

They are not the same product, but the regulation treats them together: the wording “placed under a bed or chair” covers both, and both carry the FDA name “Scale, Patient”. A chair scale that a person rolls onto in a wheelchair is a different product class, described on the wheelchair scale page above.

Zero, hold and no-lean basics

Because the scale weighs the support as well as the patient, the manufacturer quick guides from Agiliti and Versatech describe the same pattern: zero the scale with the bed in its normal weighing state, and use a hold function when items are added or removed. Each guide points to the full user manual.

Topic Agiliti Bari Classic quick reference guide Versatech 600-1100 quick guide
Zeroing States “Never zero Scale Meter with patient in bed.” Also states the meter should not be zeroed in kg mode. Recommends zeroing before each new patient, with the patient out of the bed and all equipment, linens and pillows in place and nothing in contact with the bed.
Adding or removing items A HOLD/TRANSPORT function is used when adding or removing items and when moving the bed. A FREEZE function activates hold when the reading is stable; the change is then saved with FREEZE or cancelled with WEIGH.
Other behaviours Powers down after 60 seconds of inactivity; readings are not saved; left in HOLD it will not power down, so batteries may drain. Bed-exit alarm sensitivity is adjustable from 0 to 45% in 5% steps, as a percentage of patient weight.

For accuracy, the Agiliti guide adds that the casters should be parallel to the frame and pointing toward the bed centre, the bed should not be in Trend or Reverse Trend, the scale meter should stay in its holder, and nobody should lean on the bed.

Both guides are summaries; the instructions for use for the specific bed govern.

Safe use and handling basics

  • The instructions for use for the exact model govern; quick guides are not a replacement for the user manual.
  • Anything resting on the bed is part of the reading: linens, pillows and equipment present at zeroing should match what is present when weighing.
  • Other objects and people touching or leaning on the bed during a weighing affect the result.
  • The display unit (kg or lb) is worth checking before a value is recorded.

Common mistakes

  • Zeroing with the patient in bed. The Agiliti guide says never to do this.
  • Changing items without hold. Both guides describe a hold function for adding or removing items.
  • Leaning on the bed while weighing. The Agiliti guide says not to.
  • Weighing with the bed tilted. The Agiliti guide lists Trend and Reverse Trend as conditions to avoid for the most accurate weight.
  • Expecting a saved reading. On the Agiliti meter readings are not stored, so the value has to be recorded when it is shown.

FAQ

Which FDA class is a bed scale?

Class I (general controls), under 21 CFR 880.2720 “Patient scale”, product code FRW. It is exempt from premarket notification, subject to the limitations in 21 CFR 880.9.

Does a bed scale weigh only the patient?

No. The regulation describes under-bed devices as weighing “both the support and the patient”, which is why manufacturers specify zeroing with the patient out of the bed and a hold function when items change.

Is a chair scale a bed scale?

Not the same product, but the same FDA regulation (21 CFR 880.2720) covers devices placed under a bed or chair. A wheelchair platform scale is classified separately under 21 CFR 890.3940.

Who uses a bed scale?

Nurses, care staff, biomedical engineers and buyers of hospital equipment, for patients who cannot stand on a scale.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Bed Scale: Types, FDA Class I and Zeroing Rules

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →