Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop fetal scalp electrode supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

What Is a Fetal Scalp Electrode? Spiral vs Circular, FDA Class II

Fetal scalp electrode explained: what it is, spiral vs circular types, FDA Class II code HGP and what device records state.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Who uses it: labor and delivery clinicians use fetal scalp electrodes; biomedical engineers, clinic staff and buyers meet them in catalogues and regulatory records. This page describes products and general use; it is not medical advice.

A fetal scalp electrode (FSE) is a single-patient sensor that attaches directly to the fetal scalp during labor to pick up the fetal heart’s electrical signal for a monitor. In US regulation it is a Class II device, and the generic type includes both disposable spiral electrodes and reusable circular electrodes.

What a fetal scalp electrode is

Under 21 CFR 884.2675, a fetal scalp circular (spiral) electrode and applicator is “a device used to obtain a fetal electrocardiogram during labor and delivery.” It makes electrical contact between fetal skin and an external monitoring device by a shallow subcutaneous puncture of fetal scalp tissue with a curved needle or needles (eCFR, checked 2026-11-01).

Because it contacts the fetus directly, it is an internal monitoring method. External methods, such as the belt-mounted transducer described in the tocodynamometer guide, do not penetrate tissue. Handheld listening devices are a different category again; see the fetoscope guide.

How it is built

A published case report describes the sensor as containing a spiral wire tip that attaches it to the fetal scalp (BMC Pregnancy and Childbirth, 2022, checked 2026-11-01). The regulation pairs the electrode with an applicator, so listings name both. The electrode connects to a monitor through a lead; the monitor converts the signal into a heart rate tracing.

Types and variants

Type Reuse Source
Spiral electrode Nonreusable 21 CFR 884.2675(a)
Circular electrode Reusable 21 CFR 884.2675(a)

Both variants are in the same regulation and the same FDA product code. The regulation does not rank them or say which setting suits which.

Regulatory identity: what to look for in records

Item Value Source
Regulation number 21 CFR 884.2675 eCFR
FDA classification Class II (performance standards) eCFR; openFDA classification record
FDA product code HGP, “Electrode, Circular (Spiral), Scalp And Applicator” openFDA classification database
Review specialty Obstetrics/Gynecology openFDA classification database
GMDN term 35038, “Foetal scalp electrode, spiral” (as recorded in one device listing) FDA AccessGUDID

What one device listing states

The FDA AccessGUDID record for the Goldtrace One fetal spiral electrode (Clinical Innovations) is one example of how a listing reads: it is packaged sterile, labeled single-use, labeled as not made with natural rubber latex, and carries no MRI safety information in its labeling (accessed 2026-11-01). Other products’ listings differ, so read the specific record or the instructions for use for the product in question. This is an example of a record, not a recommendation.

Safe use and handling basics

  • It is a clinician-applied device. Use follows the manufacturer’s instructions for use and the facility’s protocols; this page gives no application steps and no guidance on whether it suits a given patient.
  • The case report notes that most frequently reported complications of use include cellulitis, abscess, sepsis, fetal cephalohematoma and meningitis, and maternal endometritis and chorioamnionitis.
  • Check that a product’s labeling states sterile or nonsterile and single-use or reusable, and follow the instructions for use for handling and disposal.

Common mistakes

  • Confusing it with an external transducer. The tocodynamometer and external Doppler sit on the abdomen; the FSE contacts the fetus. See the ultrasound probe types guide for the external imaging side.
  • Treating spiral and circular as interchangeable in a record. The regulation distinguishes nonreusable spiral from reusable circular electrodes.
  • Assuming the applicator is separate. The regulated device type is the electrode and applicator together.

FAQ

What is a fetal scalp electrode used for?

To obtain a fetal electrocardiogram during labor and delivery, per 21 CFR 884.2675.

Is a fetal scalp electrode a Class II device?

Yes. 21 CFR 884.2675 classifies the fetal scalp circular (spiral) electrode and applicator as Class II (performance standards).

Is a fetal scalp electrode single-use?

The spiral type is described as nonreusable in the regulation, and the example AccessGUDID listing is labeled single-use. The regulation also covers reusable circular electrodes.

Sources

  • 21 CFR 884.2675, Fetal scalp circular (spiral) electrode and applicator, eCFR: ecfr.gov (checked 2026-11-01).
  • openFDA device classification, product code HGP: api.fda.gov (checked 2026-11-01).
  • FDA AccessGUDID, Goldtrace One Fetal Spiral Electrode: accessgudid.nlm.nih.gov (checked 2026-11-01).
  • Case report on a fetal scalp electrode, BMC Pregnancy and Childbirth, 2022: PMC9701356 (checked 2026-11-01).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is a Fetal Scalp Electrode? Spiral vs Circular, FDA Class II

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →