Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop eye tracker supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

What Is an Eye Tracker? How It Works and the FDA Eye Movement Monitor Class

Eye trackers estimate gaze from pupil and corneal reflection or record eye movement with electrodes; FDA calls the electrode type an eye movement monitor.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product and regulatory information only. This page is not medical advice and does not describe any clinical procedure.

Short answer

An eye tracker is a device that measures where a person is looking or how their eyes move. Most research and head-mounted trackers use cameras and near-infrared light to estimate the point of regard. A different, electrode-based type measures eye movement as an electrical signal. In US medical-device regulation, “eye movement monitor” has a narrower meaning than “eye tracker”.

Definition and scope

Head-mounted eye gaze trackers “resolve the point-of-regard, namely where the subject is looking in a scene” (Cognolato, Atzori and Müller, 2018). The same literature describes uses such as controlling hand prostheses, wheelchairs, computers and communication systems, and research in neurocognitive science and robotics. Related CASRAI guides cover human-computer interaction, human factors engineering and, for bench-side ergonomics, microscope ergonomics.

Two different things are called eye tracking, and they should not be confused:

  • Gaze tracking: estimating where someone is looking, usually from camera images of the eye.
  • Eye movement monitoring: recording how the eyes move, which can be done with electrodes placed around the eyes.

How eye trackers work

Video-based tracking (pupil and corneal reflection)

Video-oculography is described as “probably the most frequently used method in nonclinical settings”, and all six head-mounted devices surveyed by Cognolato and colleagues use it. A near-infrared light source creates a reflection (glint) on the cornea. In the bright-pupil arrangement the source is close to the camera’s optical axis; in the dark-pupil arrangement it is farther away. Gaze is then estimated from “the relative position between the glint and the pupil center”. Because eyes differ between people, “a personal calibration is therefore required in order to assure accurate and reliable gaze point estimation.”

Ban and colleagues (2022) add that this approach needs high-resolution eye images, and that pupil tracking becomes harder when the contrast between pupil and iris is low.

Electrode-based tracking (electrooculography)

Electrooculography (EOG) uses “the electric potential difference between the retina and the cornea”. Electrodes are placed around the eyes or on the forehead, and the signal is typically in the range of 50 to 3,500 microvolts. The same review notes that EOG devices “cause discomfort due to their bulky and rigid properties”, that conventional EOG “can only be performed in a stationary lab setup”, and that “the blink signal is not an EOG signal”.

Types compared

Feature Video-based (PCCR) Electrode-based (EOG)
What is measured Relative position of corneal glint and pupil centre in eye images Potential difference between retina and cornea
Output described in sources Point of regard; head-mounted devices also output scene video with a gaze overlay An electrical signal recorded through electrodes
Sampling rate 30 Hz to 400 Hz across six surveyed head-mounted devices Not given in the sources used here; signal amplitude is typically 50 to 3,500 microvolts
Calibration Personal calibration required Not described in the sources used here; electrodes are placed around the eyes or on the forehead
Practical limit noted Needs high-resolution eye images; low pupil/iris contrast is harder Conventional systems bulky; stationary lab setup

Where it matters for labs, clinics and supply decisions

The US regulatory term is “eye movement monitor”. Under 21 CFR 886.1510 it is defined as “an AC-powered device with an electrode intended to measure and record ocular movements”, and it is classified as Class II. The openFDA classification database (data last updated 2026-10-19) lists two product codes under that regulation, both in the ophthalmic panel with a 510(k) submission type:

Product code Device name in FDA database Class Regulation
HLL Monitor, Eye Movement 2 21 CFR 886.1510
HMC Monitor, Eye Movement, Diagnostic 2 21 CFR 886.1510

The practical consequence for anyone reading a catalogue or procurement document is that the regulation’s wording describes an electrode-based, mains-powered device. It does not describe a camera-based tracker, and this page makes no statement about whether any particular camera-based product is or is not regulated as a medical device. Class II devices of this kind reach the US market through premarket notification; see the 510(k) premarket notification guide for how that route works.

Specification checklist drawn from the sources

When comparing descriptions of eye-tracking equipment, the sources above support asking these questions:

  • Is the measurement principle camera-based (pupil and corneal reflection) or electrode-based (EOG)?
  • What is the sampling rate? Surveyed head-mounted devices range from 30 Hz to 400 Hz.
  • Does the output include gaze position and scene video, or a recorded electrical signal?
  • Is a personal calibration step required for each user?
  • Is the unit head-mounted or fixed, and does the stated use environment match, given that conventional EOG is described as stationary-lab equipment?

Common misunderstandings

  • “Eye tracker” and “eye movement monitor” are the same thing. The FDA regulation text defines the latter as an electrode-based device.
  • EOG detects blinks as part of the same signal. Ban and colleagues state that the blink signal is not an EOG signal.
  • Calibration is optional. For video-based gaze estimation, Cognolato and colleagues state that personal calibration is required for reliable gaze estimates.
  • All trackers sample at the same rate. The surveyed devices alone span 30 Hz to 400 Hz.

FAQ

What is an eye tracker used for?

Head-mounted eye trackers are described in the literature as resolving where a person is looking in a scene, with applications including controlling prostheses, wheelchairs, computers and communication systems, and research in neurocognitive science and robotics.

How does an eye tracker work?

Most video-based trackers illuminate the eye with near-infrared light and estimate gaze from the position of the corneal glint relative to the pupil centre, after a per-user calibration. Electrode-based systems instead record the electrical potential difference between retina and cornea.

Is an eye tracker a medical device?

The FDA’s regulation for an “eye movement monitor” (21 CFR 886.1510, Class II) covers an AC-powered device with an electrode that measures and records ocular movements. Whether another product falls under a given regulation depends on its intended use and the regulator’s determination, which this page does not assess.

What does Class II mean for an eye movement monitor?

The FDA classification record lists product codes HLL and HMC as Class 2 under 21 CFR 886.1510, with a 510(k) submission type.

Sources

  • 21 CFR 886.1510, Eye movement monitor, Legal Information Institute, Cornell Law School: law.cornell.edu/cfr/text/21/886.1510 (checked 2026-10-31).
  • openFDA device classification database, product codes HLL and HMC: api.fda.gov/device/classification.json (checked 2026-10-31; data last updated 2026-10-19).
  • Ban S, Lee YJ, Kim KR, Kim J-H, Yeo W-H. Advances in Materials, Sensors, and Integrated Systems for Monitoring Eye Movements. Biosensors (Basel) 2022;12(11):1039. PMC9688058, doi:10.3390/bios12111039 (checked 2026-10-31).
  • Cognolato M, Atzori M, Müller H. Head-mounted eye gaze tracking devices: An overview of modern devices and recent advances. J Rehabil Assist Technol Eng 2018;5:2055668318773991. PMC6453044 (checked 2026-10-31).

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is an Eye Tracker? How It Works and the FDA Eye Movement Monitor Class

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →