Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop scd machine supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

What Is an SCD Machine? Sequential Compression Devices Explained

A sequential compression device (SCD machine) inflates leg or foot sleeves to prevent blood pooling. Parts, garment types and FDA Class II status explained.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

An SCD machine is a sequential compression device: a pump-and-controller system that periodically inflates sleeves wrapped around the legs (or feet) to keep blood from pooling in the limb. In US regulatory language it is a “compressible limb sleeve,” and the Kendall SCD 700 Series is one cleared example. Who uses it: hospital and clinic staff who apply prescribed mechanical prophylaxis, biomedical and procurement staff who maintain or source the equipment, and students learning the terminology.

What an SCD machine is

FDA’s regulation for this device type, 21 CFR 870.5800, defines a compressible limb sleeve as “a device that is used to prevent pooling of blood in a limb by inflating periodically a sleeve around the limb.” It is a Class II device (performance standards) (21 CFR 870.5800, checked 2026-11-07). In FDA’s product-code database it is listed as product code JOW, “Sleeve, Limb, Compressible,” under the Cardiovascular review panel (openFDA classification record, checked 2026-11-07).

The manufacturer-cleared purpose of the Kendall SCD 700 Sequential Compression Controller is to apply intermittent pneumatic compression to increase venous blood flow in at-risk patients, in order to help prevent deep vein thrombosis (DVT) and pulmonary embolism (FDA 510(k) K102737, checked 2026-11-07).

One device, many names

Searches for “scd machine,” “scd pump,” “hospital leg compression machine,” “scd compression device” and “DVT pump” all describe the same device class: an intermittent pneumatic compression (IPC) system. “SCD” here means sequential compression device. It is unrelated to SCD as an abbreviation for sickle cell disease.

How it is built

The Kendall SCD 700 510(k) summary describes the system as a controller, tubing sets provided with the controller, and single-patient-use garments purchased separately. The controller delivers air through the tubing to a pair of disposable garments, one per limb.

Component What the cleared documentation says
Controller (the “pump”) Delivers air through tubing sets to the garments; applies sequential, gradient pressure. Tested for battery operation and alarms.
Tubing sets Supplied with the controller; connect it to the garments.
Garments (sleeves and cuffs) Disposable, single-patient use, purchased separately from the controller. Materials evaluated under ISO 10993-1.

Source for the table: FDA 510(k) K102737, checked 2026-11-07. The same submission lists testing to IEC 60601-1, UL 60601-1, IEC 60601-1-2, EN 55011 and IEC 60529.

How the cycle works

According to the 510(k) summary, after a compression cycle reaches its set pressure, the controller measures how long the limbs take to refill with blood and waits that period before starting the next compression. The cycle therefore adapts to the patient rather than running on a fixed timer.

Types: SCD boots, leg sleeves and foot cuffs

“SCD boots” and “SCD sleeves” are everyday names for the garments. The 510(k) covers both leg sleeves and foot cuffs, with different cleared indications.

Garment Cleared indications (K102737)
Leg sleeve (SCD on legs) DVT and pulmonary embolism prophylaxis
Foot cuff DVT prophylaxis plus further indications listed in the 510(k) Indications for Use statement

Source: FDA 510(k) K102737 Indications for Use, checked 2026-11-07.

How it is regulated

  • Class II device under 21 CFR 870.5800, product code JOW (FDA, checked 2026-11-07).
  • The Kendall SCD 700 was cleared through the 510(k) pathway using the Kendall SCD Express Portable Compression System (K040511) as predicate; its summary is dated September 17, 2010.
  • The indications statement is marked prescription use (21 CFR 801 Subpart D), not over-the-counter.

Safe use and handling basics

  • It is a prescription device: whether a patient uses one, which garment, and for how long is a clinician’s decision, and the manufacturer’s instructions for use govern setup and alarms.
  • Garments are labelled single-patient use; the controller is the reusable part.
  • Mechanical compression is one form of VTE prophylaxis and is separate from compression stockings; see DVT prophylaxis with compression stockings and what a compression sock is. Risk assessment tools such as the Caprini score are used by clinicians to decide on prophylaxis.

Common mistakes

  • Treating an SCD pump as interchangeable with a compression stocking. One is a powered pneumatic system, the other is a passive garment.
  • Confusing “SCD” the device with sickle cell disease when searching or reading product listings.
  • Assuming leg sleeves and foot cuffs share the same indications; the cleared list differs (table above).
  • Treating a controller and its garments as one purchase: the cleared system lists garments as separate, single-patient-use items.

Frequently asked questions

What is a compression machine used for?

The Kendall SCD 700 is cleared to apply intermittent pneumatic compression to increase venous blood flow in at-risk patients to help prevent DVT and pulmonary embolism (FDA K102737). Foot cuffs carry additional cleared indications listed in the same document.

What are SCD boots?

The disposable sleeves or cuffs that wrap the legs or feet and inflate in sequence. They connect to the controller through tubing and are single-patient use.

How many times a day should you use a leg compression machine?

No universal figure exists in the regulatory documents. Duration and schedule are set by the prescribing clinician and the manufacturer’s instructions for use.

How much do leg compression machines cost?

This page does not give prices. Cost depends on the controller model, the garments (sold separately) and the supplier or care setting.

Can I use an SCD machine at home or get insurance coverage?

The cleared indications for the Kendall SCD 700 are prescription use only. Home use and coverage depend on a prescriber’s order and on the payer’s own rules, which this page does not cover.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is an SCD Machine? Sequential Compression Devices Explained

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →