Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop breathalyzer supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

What Is a Breathalyzer? Types, Standards and Use

A breathalyzer measures breath alcohol. Learn screening vs evidential devices, NHTSA evaluation levels and the air blank before a DOT confirmation test.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

A breathalyzer is an instrument that measures the alcohol concentration in a person’s breath. This page explains the two device classes used in US federal workplace testing, how NHTSA decides which instruments conform, and how screening and confirmation tests relate.

This page describes products and general use; it is not medical advice.

What a breathalyzer is

A breathalyzer is a breath alcohol testing device. In the US Department of Transportation (DOT) workplace testing rules, the result is expressed as an alcohol concentration, defined in 49 CFR 40.3 as grams of alcohol per 210 liters of breath. Who uses it: employers and testing programs regulated by the DOT, and the trained staff who run the tests.

How it works and how it is specified

Federal sources describe what a device must be evaluated against rather than a single design. NHTSA converted its earlier standard into the Model Specifications for Evidential Breath Testing Devices in 1984. A 1993 amendment set evaluation levels of 0.000, 0.020, 0.040, 0.080 and 0.160 BAC and added a test for the presence of acetone and an expanded definition of alcohol (Federal Register, 11 March 2010). Instruments found to conform to the Model Specifications are listed on NHTSA’s Conforming Products List (CPL), which has separate Mobile and Nonmobile columns; some listed instruments are described as intended for stationary or roadside operation. A 2004 notice, titled Model Specifications for Devices To Measure Breath Alcohol, gives the example of a hand held device intended for stationary or roadside operation, and notes that instruments meeting the current specifications also meet the Model Specifications for Screening Devices to Measure Alcohol in Bodily Fluids.

Types of breathalyzer

In 49 CFR Part 40 there are two classes, defined by what they may be used for.

Type What the rule says Key difference
Alcohol screening device (ASD) A breath or saliva device, other than an evidential breath testing device, that is approved by NHTSA (40.3). It can be used only for screening tests and must not be used for confirmation tests (40.229). Screening only
Evidential breath testing device (EBT) A device approved by NHTSA for the evidential testing of breath (40.3). A confirmation device must distinguish alcohol from acetone at the 0.02 alcohol concentration level (40.231(b)(4)). Used for the confirmation test

Separately, the NHTSA CPL distinguishes mobile (including handheld) from nonmobile instruments (Federal Register, 2010 and 2004).

Specifications that matter

Specification Value Source
Unit of measure Grams of alcohol per 210 liters of breath 49 CFR 40.3
NHTSA evaluation levels 0.000, 0.020, 0.040, 0.080, 0.160 BAC Federal Register, 11 March 2010
Acetone Evaluation includes a test for the presence of acetone; confirmation devices must distinguish alcohol from acetone at 0.02 Federal Register 2010; 49 CFR 40.231(b)(4)
Confirmation trigger A screening result of 0.02 or greater leads to a confirmation test; a confirmation result of 0.02 or higher triggers the employee signing step 49 CFR 40.3, 40.255
DOT result referenced at 0.04 0.04 or greater is referenced for a DOT alcohol test result 49 CFR 40.285(b)

How to choose

The criteria that the sources state are about regulatory status, not features. For DOT-regulated testing, an evidential device must be approved by NHTSA for the evidential testing of breath, and a screening device must be an NHTSA-approved ASD. NHTSA’s CPL is the list of instruments found to conform to the Model Specifications. Calibrating devices used with breath alcohol testing must appear on NHTSA’s Conforming Products List of Calibrating Units for Breath Alcohol Tests (49 CFR 40.233). A device that is not listed or approved cannot be treated as meeting these rules.

Regulatory context for use

This section summarises what 49 CFR Part 40 says about the order of a DOT alcohol test; it is not an instruction. Follow the device maker’s instructions and your program’s procedures.

  • A screening test comes first; a screening result of 0.02 or greater leads to a confirmation test on an EBT.
  • Before the confirmation test, an air blank is conducted on the EBT being used (40.253). For EBTs this is a reading of ambient air containing no alcohol (40.3).
  • A screening device cannot be used for the confirmation (40.229).

These rules apply to the US DOT workplace regime. Other settings, such as roadside enforcement or clinical use, have their own rules.

Common mistakes

  • Using a screening device to confirm a result. The rule forbids it (40.229).
  • Assuming a device conforms because it is sold as a breathalyzer; conformity is shown by NHTSA approval and the CPL.

For related reading on keeping measuring instruments within specification, see what calibration is. Related equipment guides: what a medical device is, a pulse oximeter and a medical thermometer, and how a point-of-care diagnostic station is equipped. Diagnostic equipment is also listed in the diagnostic, monitoring and imaging category at lac.us.

FAQ

How does a breathalyzer work?

It measures the alcohol concentration in breath and reports it as grams of alcohol per 210 liters of breath. Federal sources specify how instruments are evaluated (levels from 0.000 to 0.160, plus an acetone test) rather than prescribing one design.

How is a breathalyzer used?

Use depends on the setting. In US DOT workplace testing, 49 CFR Part 40 describes a screening test followed, where needed, by a confirmation test on an EBT preceded by an air blank. Follow the manufacturer’s instructions for use.

What types of breathalyzer are there?

Under 49 CFR Part 40, screening devices (ASDs, which may be breath or saliva devices) and evidential breath testers (EBTs). NHTSA’s list also separates mobile and nonmobile instruments.

Sources

  • NHTSA, Federal Register notice of 11 March 2010, govinfo.gov, checked 3 November 2026.
  • NHTSA, Model Specifications for Devices To Measure Breath Alcohol, Federal Register of 14 July 2004, govinfo.gov, checked 3 November 2026.
  • 49 CFR Part 40 (2023 edition), sections 40.3, 40.229, 40.231, 40.233, 40.251, 40.253, 40.255, 40.285, govinfo.gov, checked 3 November 2026.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about What Is a Breathalyzer? Types, Standards and Use

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →