What a breathalyzer is
A breathalyzer is a breath alcohol testing device. In the US Department of Transportation (DOT) workplace testing rules, the result is expressed as an alcohol concentration, defined in 49 CFR 40.3 as grams of alcohol per 210 liters of breath. Who uses it: employers and testing programs regulated by the DOT, and the trained staff who run the tests.
How it works and how it is specified
Federal sources describe what a device must be evaluated against rather than a single design. NHTSA converted its earlier standard into the Model Specifications for Evidential Breath Testing Devices in 1984. A 1993 amendment set evaluation levels of 0.000, 0.020, 0.040, 0.080 and 0.160 BAC and added a test for the presence of acetone and an expanded definition of alcohol (Federal Register, 11 March 2010). Instruments found to conform to the Model Specifications are listed on NHTSA’s Conforming Products List (CPL), which has separate Mobile and Nonmobile columns; some listed instruments are described as intended for stationary or roadside operation. A 2004 notice, titled Model Specifications for Devices To Measure Breath Alcohol, gives the example of a hand held device intended for stationary or roadside operation, and notes that instruments meeting the current specifications also meet the Model Specifications for Screening Devices to Measure Alcohol in Bodily Fluids.
Types of breathalyzer
In 49 CFR Part 40 there are two classes, defined by what they may be used for.
| Type | What the rule says | Key difference |
|---|---|---|
| Alcohol screening device (ASD) | A breath or saliva device, other than an evidential breath testing device, that is approved by NHTSA (40.3). It can be used only for screening tests and must not be used for confirmation tests (40.229). | Screening only |
| Evidential breath testing device (EBT) | A device approved by NHTSA for the evidential testing of breath (40.3). A confirmation device must distinguish alcohol from acetone at the 0.02 alcohol concentration level (40.231(b)(4)). | Used for the confirmation test |
Separately, the NHTSA CPL distinguishes mobile (including handheld) from nonmobile instruments (Federal Register, 2010 and 2004).
Specifications that matter
| Specification | Value | Source |
|---|---|---|
| Unit of measure | Grams of alcohol per 210 liters of breath | 49 CFR 40.3 |
| NHTSA evaluation levels | 0.000, 0.020, 0.040, 0.080, 0.160 BAC | Federal Register, 11 March 2010 |
| Acetone | Evaluation includes a test for the presence of acetone; confirmation devices must distinguish alcohol from acetone at 0.02 | Federal Register 2010; 49 CFR 40.231(b)(4) |
| Confirmation trigger | A screening result of 0.02 or greater leads to a confirmation test; a confirmation result of 0.02 or higher triggers the employee signing step | 49 CFR 40.3, 40.255 |
| DOT result referenced at 0.04 | 0.04 or greater is referenced for a DOT alcohol test result | 49 CFR 40.285(b) |
How to choose
The criteria that the sources state are about regulatory status, not features. For DOT-regulated testing, an evidential device must be approved by NHTSA for the evidential testing of breath, and a screening device must be an NHTSA-approved ASD. NHTSA’s CPL is the list of instruments found to conform to the Model Specifications. Calibrating devices used with breath alcohol testing must appear on NHTSA’s Conforming Products List of Calibrating Units for Breath Alcohol Tests (49 CFR 40.233). A device that is not listed or approved cannot be treated as meeting these rules.
Regulatory context for use
This section summarises what 49 CFR Part 40 says about the order of a DOT alcohol test; it is not an instruction. Follow the device maker’s instructions and your program’s procedures.
- A screening test comes first; a screening result of 0.02 or greater leads to a confirmation test on an EBT.
- Before the confirmation test, an air blank is conducted on the EBT being used (40.253). For EBTs this is a reading of ambient air containing no alcohol (40.3).
- A screening device cannot be used for the confirmation (40.229).
These rules apply to the US DOT workplace regime. Other settings, such as roadside enforcement or clinical use, have their own rules.
Common mistakes
- Using a screening device to confirm a result. The rule forbids it (40.229).
- Assuming a device conforms because it is sold as a breathalyzer; conformity is shown by NHTSA approval and the CPL.
For related reading on keeping measuring instruments within specification, see what calibration is. Related equipment guides: what a medical device is, a pulse oximeter and a medical thermometer, and how a point-of-care diagnostic station is equipped. Diagnostic equipment is also listed in the diagnostic, monitoring and imaging category at lac.us.
FAQ
How does a breathalyzer work?
It measures the alcohol concentration in breath and reports it as grams of alcohol per 210 liters of breath. Federal sources specify how instruments are evaluated (levels from 0.000 to 0.160, plus an acetone test) rather than prescribing one design.
How is a breathalyzer used?
Use depends on the setting. In US DOT workplace testing, 49 CFR Part 40 describes a screening test followed, where needed, by a confirmation test on an EBT preceded by an air blank. Follow the manufacturer’s instructions for use.
What types of breathalyzer are there?
Under 49 CFR Part 40, screening devices (ASDs, which may be breath or saliva devices) and evidential breath testers (EBTs). NHTSA’s list also separates mobile and nonmobile instruments.