What Is Digital Image Correlation (DIC)? Principles and Setup

Digital image correlation (DIC) measures full-field surface strain by matching speckle patterns across images. Principles, parameters, 2D vs stereo.

Written and maintained by CASRAI Editorial Board

Published

On this page

Digital image correlation (DIC) is an optical technique that measures how the surface of a test piece moves and deforms during a mechanical test, by matching grey-level patterns between a reference image and later images. From the matched positions it derives full-field displacements and strains without touching the specimen. This page is general information for researchers and lab staff; it is not a substitute for hands-on or vendor training.

Short answer

DIC compares photographs of a patterned surface taken before and during loading. Because the pattern deforms with the surface, tracking it gives the surface coordinates at every point, and displacements, strains and strain rates follow from those coordinates. One camera gives 2D measurements; two calibrated cameras give 3D (stereo-DIC).

Definition and scope

The iDICs Good Practices Guide for Digital Image Correlation (Edition 2, October 2025) defines DIC as an optically based technique that measures the evolving full-field 2D or 3D coordinates on the surface of a test piece throughout a mechanical test. Derived quantities include displacements, strains, strain rates, velocities and curvatures. The guide describes it as non-contact and independent of material or length scale, and lists applications on metals, polymers, concrete, geological samples, biological tissues and battery electrodes.

DIC belongs with other optical methods used in materials and biomechanics labs. For a neighbouring optical-measurement topic see digital holographic microscopy; for the field that often measures tissue and structure deformation see what is biomechanics.

How DIC works

What is correlation in image processing?

In DIC, “correlation” means matching. The method rests on the idea of optical flow: the grey-level intensity of a small patch of the surface is assumed to be conserved as the image deforms, written in the guide as F(x) = G(x + u(x)), where F is the reference image, G the deformed image and u the displacement. The software searches for the displacement u that makes the two patches agree best under a chosen matching criterion.

What is an example of a digital image in DIC?

A digital image here is a grid of pixels, each holding a grey-level value. A typical DIC image is a camera frame of a specimen surface carrying a speckle pattern, taken before loading (the reference image) and repeatedly during the test. The guide’s worked example uses cameras of 1.3, 5 and 20 megapixels.

The measurement chain

  1. Surface pattern. The surface needs a natural or applied pattern. Applied patterns are typically roughly circular speckles of uniform size at random locations. The guide gives an optimum feature size of 3 to 5 pixels, for both light and dark features, and says pattern quality is usually judged by visual inspection; quantitative metrics are typically unnecessary outside research.
  2. Cameras and calibration. One camera suffices for 2D-DIC. Obtaining 3D coordinates needs two cameras at a stereo angle (stereo-DIC), and the camera and lens system is calibrated by imaging a calibration target with known separation lengths. The guide prefers “stereo-DIC” to “3D-DIC” to avoid confusion with digital volume correlation.
  3. Correlation. In local DIC the user defines a region of interest; data points are each centred in a subset and spaced at the step size. Each subset is correlated from the reference image to later images using an interpolant, a shape function and a matching criterion.
  4. Strain computation. Strain is computed from displacement gradients, using a strain window or filter. Noise floor and bias depend on camera selection, image contrast, pattern feature size, subset size and shape function, among other factors, and uncertainty quantification completes the processing.

Local, global and 2D versus stereo: a sourced cross-walk

All rows below come from the iDICs good practices guide (Edition 2, 2025).

Choice or parameter What the guide states
2D-DIC One camera; measures 2D surface coordinates.
Stereo-DIC Two cameras at a stereo angle, calibrated with a target of known separation lengths; gives 3D coordinates.
Local DIC User-defined region of interest; subsets centred on data points spaced at the step size.
Global DIC Interpolant defined over the whole region of interest at once, often with a finite-element discretisation.
Speckle feature size Optimum 3 to 5 pixels; about 50% density for a near-ideal pattern.
Subset size About 15 x 15 pixels is possible for a near-ideal pattern; 21 x 21 pixels is the recommended practical minimum.
Step size Typically one-third to one-half of the subset size.
Subset trade-off Larger subsets lower noise but add spatial smoothing.

As a worked illustration from the same guide: a 31-pixel subset with an 11-pixel step and an 11-point Gaussian strain filter. Because subset and filter choices trade noise against smoothing, they are worth reporting alongside strain results.

Where it matters for labs

Because DIC records full-field surface data rather than a single gauge reading, it suits tests where strain is non-uniform, such as around notches or in heterogeneous materials. Labs adopting it still need to plan the speckle pattern, camera resolution relative to the field of view, and the analysis settings above. Related imaging topics on CASRAI include microscope objective selection and confocal microscopy.

On standards: the iDICs guide is a community good-practices document produced by its Standardization Committee, free to reproduce with attribution. A 2012 NIST publication page (Read, Cheng and Sutton) describes a proposed standardisation effort covering image quality, displacement and strain analysis, measurement uncertainty, surface treatment, acquisition, analysis and reporting. The guide itself states that it does not address health and safety, which remain the responsibility of the laboratory and user.

Common misunderstandings

  • DIC is not DIP. Digital image processing (DIP) is the broad field of manipulating digital images. DIC uses image matching as a measurement tool for deformation.
  • “Correlation” is not a statistical relationship between variables. It means matching grey-level patterns between images.
  • It is not tied to one material. The guide describes it as independent of material and length scale.
  • More pixels do not remove the need for a good pattern. Noise floor and bias depend on contrast, feature size and subset settings as well as the camera.

FAQ

What is an example of a digital image?

A grid of pixels with grey-level values, such as a camera frame of a speckled specimen surface before loading.

What is correlation in image processing?

Matching patterns between images. In DIC, it is the search for the displacement that best aligns grey-level patterns in a reference and a deformed image.

How does DIC work?

It images a patterned surface during a test, correlates subsets between the reference and later images, and computes displacements and then strains from the displacement gradients.

What are the steps in DIP?

DIP (digital image processing) is a different, broader field from DIC. The DIC measurement chain is set out under “The measurement chain” above: pattern, cameras and calibration, correlation, strain computation.

Sources

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about What Is Digital Image Correlation (DIC)? Principles and Setup

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →