Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
A wiped-film evaporator (WFE) is a continuous separation machine that spreads a liquid feed into a thin, mechanically agitated film on a heated surface, usually under vacuum, so that the more volatile components evaporate quickly and leave the heavier, less volatile material behind. Because the film is thin, the vacuum lowers the boiling temperature and the liquid spends only seconds on the hot surface, so the design suited to viscous, heat-sensitive or fouling materials that would degrade or foul a conventional still. The same machine is also sold as a thin-film evaporator, and with an internal condenser it can operate as a short-path or molecular still.
This page explains how a wiped-film evaporator is built, the rotor types manufacturers describe, the surface-area range of published models, how the design differs from related evaporation equipment, and where it is used, including cannabinoid and botanical-extract distillation. Everything below comes from manufacturer and laboratory descriptions listed in the Sources section. Those descriptions give no operating temperatures, throughputs or prices, so none are stated here.
What a wiped-film evaporator is
GMM Pfaudler describes its wiped film evaporator as a unit that continuously separates volatile components by spreading the feed as a mechanically agitated thin film on a heated surface, under high vacuum, with a residence time of seconds. The Lawrence Berkeley National Laboratory Advanced Biofuels and Bioproducts Process Development Unit (ABPDU) describes its Pope Scientific 2-inch unit in similar terms: it continuously separates compounds by distributing the material across a large heated area in a controlled vacuum environment.
The defining feature is the wiper. A rotor with wiper blades turns inside a heated cylinder and keeps pushing the liquid into a renewed film. Sulzer explains that this continuous renewal of the film limits deposits and fouling on the heat-transfer surface. Pfaudler states the same benefit in different words: the blades continually clean the heat-transfer surface, which is why the equipment suits products that foul.
Who uses it. The manufacturer pages name chemical, petrochemical, polymer, pharmaceutical, food and nutraceutical, oleochemical and waste-treatment users, and the ABPDU unit is a research and process-development instrument. Extraction laboratories that distil cannabinoid oils are a further group; extraktLAB, a vendor, says its wiped-film systems distil cannabinoids such as THC and CBD to concentrate them.
How a wiped-film evaporator works and is built
The process path
extraktLAB describes the sequence in a form that applies to most designs. Feed enters through a feed port and reaches the heated surface. The rotor wipers spread it into a thin film. Volatile components leave the film as vapour and travel to an internal condenser, where they are collected as a liquid. The non-volatile residue, which stays on the wall, leaves through a separate outlet. Two streams therefore come out of one pass: a distillate and a residue.
The heating jacket can be supplied with steam, hot oil or electricity, according to extraktLAB. Sulzer adds that its units can be run without recirculating the liquid, and that evaporation of more than 95 percent can be reached in a single pass.
Main components
The parts below are taken from the GMM Pfaudler and extraktLAB descriptions.
- Drive unit and rotor. Pfaudler describes a large-diameter shaft with an overhung rotor and no bottom bearing, with mechanical seals that can be replaced without removing the drive or the rotor.
- Wiper blades. Pfaudler lists slotted wiper blades in several designs and materials. The next section covers the rotor types Sulzer describes.
- Pressure vessel. A cylindrical shell with a polished inner surface and heating jackets, in which the film forms.
- Internal condenser. Pfaudler states that an internal condenser enables true short-path distillation and gives a lower pressure drop than an external condenser.
- Entrainment separators. Pfaudler fits full-length separators to prevent liquid carryover into the vapour stream.
- Heated bottom head. For viscous or high-melting bottoms, Pfaudler offers a heated bottom head with extruder blades.
- Vacuum system and ports. extraktLAB lists the vacuum system, the feed port and the discharge ports as parts of the assembly.
Pfaudler states vacuum capability down to 1 micron (0.001 Torr). Materials of construction named by the two manufacturers include stainless steel, duplex steel, high-nickel alloys, glass and glass-lined steel. Sulzer notes that in its glass-lined version all wetted parts except the rotor blades are glass-lined, and the rotor is self-supporting with no bottom bearing.
Types and variants
The wiped-film evaporator family is usually divided by rotor design and by whether an internal condenser is fitted. Sulzer documents three rotor types for its EvapCare-W line; the table at the end of this page (the data table) sets them side by side.
Rotor types
- Type L uses rigid blades that run at a defined clearance from the wall.
- Type P uses hinged wiper blades that adapt to the viscosity of the product.
- Type R uses self-adjusting rollers, which allow the film thickness to vary.
Evaporator versus short-path configuration
Pfaudler’s internal-condenser option is what turns the evaporator into a short-path still: the vapour has a very short route from the film to the condenser, so the pressure drop is small and the unit can run at low absolute pressure. The ABPDU describes a unit that can operate in three modes: as an evaporator or concentrator, as a molecular still, or as a hybrid fractional mode.
Single-stage and dual-stage systems
extraktLAB sells a dual-stage system (clearSTILL 400) and a single-stage research and development system (clearSTILL 200). In its own description, a wiped-film unit cannot fractionate without external equipment, and refining CBD typically takes two passes. That is a vendor statement about its own equipment; it illustrates why multi-stage arrangements exist rather than setting a rule for every unit.
Sizes and specifications that matter
Heat-transfer surface area is the specification that manufacturers publish most consistently, because it sets how much feed a unit can evaporate.
| Manufacturer and line | Heat-transfer surface area | Vacuum capability | Source |
|---|---|---|---|
| GMM Pfaudler wiped film evaporators | about 1.2 sq ft (0.1 m²) to 500 sq ft (46.5 m²) | down to 1 micron (0.001 Torr) | Pfaudler product page |
| Sulzer EvapCare-W | 0.025 to 50 m² | not stated on the page | Sulzer product page |
Two points follow from these figures. First, the published ranges are wide: Sulzer’s largest surface area is 2,000 times its smallest, so a catalogue family covers very different machine sizes. Second, surface area alone does not give throughput, because throughput also depends on the feed, the temperature and the vacuum; neither manufacturer publishes a figure that converts one to the other, so a capacity needs a supplier test or quotation for the actual material.
Vacuum depth matters because it sets the boiling temperature. For the general relationship between pressure and boiling point, the CASRAI page on ethanol boiling point and vacuum values shows how much the boiling temperature of a single common solvent falls as pressure drops.
How it differs from other evaporators and stills
People often compare a wiped-film evaporator with a falling-film evaporator, a rotary evaporator and a flask-based short-path still. The statements below are limited to what the sources say.
| Equipment | What the sources state | Source |
|---|---|---|
| Falling-film evaporator | Sulzer says the film in its wiped-film unit is thinner than in a falling-film evaporator, which reduces liquid load and allows higher evaporation ratios; the mechanical wiping reduces fouling by up to 50 percent. | Sulzer |
| Flask short-path still | extraktLAB describes a typical flask short-path run at about 0.1 Torr with a stir bar, as a batch process, against a wiped-film run below 0.001 Torr that is continuous. | extraktLAB comparison page |
| Wiped-film with internal condenser | Pfaudler states that the internal condenser enables true short-path distillation and lowers the pressure drop. | GMM Pfaudler |
For batch solvent removal at a bench, see the guide to the rotary evaporator, and for separating liquids with close boiling points, the guide to fractional distillation explains why column-based fractionation is a different operation from film evaporation. For small-scale solvent evaporation under a gas stream, see nitrogen evaporators.
The extraktLAB comparison page gives residence-time and film-thickness figures that disagree with each other within the same page, so this page does not use them. Where a vendor gives an operating figure, treat it as that vendor’s description of its own equipment, not a property of every wiped-film evaporator.
Uses
Pfaudler groups the applications into four kinds of material: high-viscosity products such as polymers and resins, heat-sensitive products such as nutraceuticals, highly fouling products such as used motor oil being re-refined, and high-boiling, high-molecular-weight products. Sulzer lists solvent stripping, deposit removal and the concentration of viscous products across the chemical, petrochemical, polymer, pharmaceutical, food and nutraceutical, oleochemical and waste-treatment industries.
Cannabinoid and botanical extracts
extraktLAB describes distilling cannabinoids such as THC and CBD so that they are concentrated. The reason a vacuum thin-film machine is chosen for this is the same one the manufacturers give for heat-sensitive products: a short time on the hot surface at reduced pressure.
A distillation step does not remove the need to control residual solvents in the finished product. The CASRAI guide to ICH Q3C residual solvent limits explains the residual-solvent framework used for pharmaceutical products; whether it applies to a particular botanical product depends on the product and on the rules of the market where it is sold.
Research and process development
The ABPDU at Lawrence Berkeley National Laboratory lists its Pope Scientific 2-inch wiped-film unit under purification and advanced recovery equipment, in its three modes (evaporator or concentrator, molecular still and hybrid fractional). That placement shows the machine’s role in process-development work: a small unit is used to test a separation before scale-up.
Buying and sourcing: what the manufacturer pages cover
Searches for wiped-film evaporators for sale, prices and manufacturers lead to vendor catalogues. Pfaudler, Sulzer and extraktLAB are examples of manufacturers that publish product pages, and each lists models by surface area, materials and configuration. None of the three pages read for this guide publishes a price, so a cost needs a quotation from the supplier.
The items the manufacturers themselves list as choices are the useful comparison points between quotations: heat-transfer area, materials of construction (metallic or glass-lined), the rotor type, whether an internal condenser is fitted, the vacuum capability, and the heating medium.
Operating and safety basics
The manufacturer pages do not publish operating procedures, so the instruction manual and the supplier’s commissioning guidance for the specific model are the controlling documents. The design features the sources do describe have direct handling consequences:
- The unit runs under vacuum, and Pfaudler quotes depths down to 0.001 Torr, so vacuum seals and connections are part of normal maintenance; Pfaudler designs its mechanical seals to be replaceable without removing the drive or rotor.
- The heating jacket may use steam, hot oil or electricity (extraktLAB), so the hazards of the chosen heating medium apply in addition to those of the product.
- Solvent-bearing feeds need the safeguards of the solvent in question; the CASRAI pages on solvent properties such as ethanol boiling point give a starting point for ethanol.
Common mistakes
- Treating a wiped-film evaporator as a fractionating column. extraktLAB states that a wiped-film unit cannot fractionate without external equipment and that CBD refining typically takes two passes.
- Letting the feed foul the surface. The reason for the rotor is to limit deposits; Sulzer says wiping reduces fouling by up to 50 percent, so it reduces fouling and does not abolish it.
- Ignoring carryover. Pfaudler fits full-length entrainment separators to prevent liquid carryover, which indicates that carryover of liquid into the vapour is a design concern.
- Comparing surface areas across units without checking the units. Pfaudler quotes square feet and square metres together, and the two manufacturers give different ranges; convert before comparing.
- Assuming a flask short-path result transfers directly. The vendor figures for a flask short-path (about 0.1 Torr, batch) and a wiped-film run (below 0.001 Torr, continuous) differ, so settings from one cannot be copied to the other.
Sources
- GMM Pfaudler, Wiped Film Evaporators (manufacturer product page).
- Sulzer, EvapCare-W wiped film evaporator (manufacturer product page).
- extraktLAB, Understanding Wiped Film Evaporators (vendor description).
- extraktLAB, Short Path Distillation vs Wiped Film Distillation (vendor description).
- Lawrence Berkeley National Laboratory ABPDU, Pope Scientific 2-inch Wiped Film Evaporator (laboratory equipment page).
Data: Sulzer EvapCare-W wiped-film rotor types and their described behaviour
Compares the three rotor types documented by Sulzer for its EvapCare-W wiped film evaporator: the wiping element and the behaviour the manufacturer describes. Compiled from the manufacturer's product page, without added values.
| Rotor type | Wiping element | Behaviour described by the manufacturer |
|---|---|---|
| Type L | Rigid blades | Run at a defined clearance |
| Type P | Hinged wiper blades | Adapt to the viscosity of the product |
| Type R | Self-adjusting rollers | Allow a variable film thickness |
Sources
- Sulzer, EvapCare-W wiped film evaporator (accessed 2026-11-19)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.