Skip to main content
v2026.11,986 entries · CC-BY 4.0

Work instruction template for laboratory tasks

Adapt a task-level work instruction outline, with document-control fields, an administrative example and WHO guidance on SOP-linked bench aids.

Written and maintained by CASRAI Editorial Board

Published

On this page

A work instruction template is a reusable outline for describing one defined task, its responsible role, checks and records. For laboratory work, include document identity, approval and a link to the governing procedure. The template below also separates a full instruction from a shortened bench aid, so a change to the parent procedure does not leave an outdated reminder in use.

Short answer

Use the copyable outline to capture what the task covers, who may perform it, what information is needed, how completion is checked and where the evidence belongs. Replace the brackets with approved local information. Keep document-control fields alongside the task description, rather than adding them after the document has already circulated.

This is an editorial template for adaptation, not an official WHO form or a certificate of compliance. Its distinctive check is the relationship between the instruction, its parent document and any shortened aid. WHO’s Laboratory Quality Stepwise Implementation tool makes that relationship explicit for equipment bench aids: the aid belongs with the SOP and carries the same version number.

Definition and scope

Here, a work instruction means the task-level description used within a laboratory’s own documentation system. A template is the blank structure from which that description is written. The completed instruction tells a user what to do; the record created while using it shows what actually happened. Those are different purposes, even when the documents are stored together.

Terminology varies. EPA’s April 2007 Guidance for Preparing Standard Operating Procedures, QA/G-6, acknowledges names including instructions and worksheets. It also says there is no single correct SOP format. Use the terminology defined by the local quality system instead of treating the document’s name as evidence of its authority.

The standard operating procedure definition provides the broader context. For this template, keep the task boundary narrow enough to identify its inputs and output. A title such as “Document-reference card review” is more specific than “Laboratory administration.” Neither title, on its own, establishes who can approve the resulting document.

The outline addresses document design and governance. It does not supply assay parameters, equipment settings, clinical directions or acceptance limits. Those fields must come from the approved method and applicable local procedures. Do not fill an empty technical field with a convenient example value.

Copyable work instruction template

Copy these field labels into your document editor and expand the sections that the task needs. Bracketed text is a drafting prompt. It must be replaced, or explicitly marked inapplicable under the laboratory’s own rules, before release. The layout is an editorial synthesis of the guidance in the Sources section.

Document identity and authority

Task title: [Specific activity and intended output]. Instruction identifier: [Local controlled identifier]. Revision: [Version]. Document owner: [Responsible role]. Author: [Name or role]. Reviewer and approver: [As required by the local approval process]. Issue or effective date: [Approved date]. Page: [Page number and total pages].

Governing documents: [Parent SOP identifier, title, applicable revision and controlled location]. Associated aids: [Any shortened card or appendix and its relationship to this instruction]. Distribution: [Where approved copies are available]. Review: [Responsible role and review date or rule recorded in the control system].

Task boundary and prerequisites

Purpose: [What completion achieves]. Scope: [Starting point, ending point and exclusions]. Responsible user: [Role and required qualifications or training]. Inputs: [Documents, materials, equipment or information needed]. Safety references: [Approved precautions relevant to the task, where applicable]. Definitions: [Local terms that could otherwise be ambiguous].

Task description and checks

Action description: [Clear description of each approved action, organized in the order required by the source procedure]. Supporting illustration: [A task-specific image or diagram, if useful, with a caption identifying what it shows]. Check: [Observable evidence of correct completion and the approved basis for accepting it]. Exception: [Referenced procedure and responsible role when the expected condition is absent].

Evidence and maintenance

Resulting record: [Form, log or system entry created]. Record identifier and location: [Where the evidence can be retrieved]. Access and retention: [Applicable local record-control rule]. References: [The source documents actually used]. Change history: [Revision, change summary, authorization and replacement information].

Keep the blank outline distinct from an authorized instruction. A template with completed headings can still contain unresolved decisions. For example, “[Responsible role]” is a prompt, not an assignment; “[Approved basis]” is not an acceptance criterion. The reviewer needs the decisions behind those labels.

How it is used in practice

WHO’s Quality manual template provides editable documents for laboratories and explicitly requires local customization. Apply that principle here: retain useful structure, but write the content around the actual local task. Copying another laboratory’s role names or document locations would not establish that those arrangements exist in yours.

Think of completion as a correspondence check. The purpose names an output; the task description explains the work that produces it; the check identifies evidence; and the record field locates that evidence. If the output is a revised reference card, an instrument calibration record would not be a sensible completion record for that task. This is a template-design example, not a new laboratory requirement.

Review extends beyond the main paragraph. WHO’s document-control activity includes checking appendixes, forms and references to equipment, locations and other documents. A correct instruction with a broken reference is therefore unfinished under that guidance. The local document control procedure should govern how the draft becomes an approved, distributed version.

Where a task needs a full procedure rather than a narrow instruction, use the lab SOP writing guide for that broader structure. Avoid squeezing a multi-role process into a task card merely to make it fit on one page.

A full instruction, a shortened aid and a completed record serve different functions. WHO’s guidance for testing outside laboratory settings describes job aids as short visual versions of SOPs. Its laboratory equipment guidance describes bench aids as accessible reminders of routine work, with the full SOP available for more specific procedures.

A checklist can serve another purpose. EPA QA/G-6 distinguishes it from the SOP it supports and describes referencing forms or checklists where they are used. A blank checklist organizes expected entries; a completed copy may become evidence of the activity. Treating both as the same object hides the distinction between changing an instruction and preserving a record.

The downloadable data table below compiles these source-specific distinctions. It preserves the source context rather than asserting one universal document hierarchy. For a fuller discussion of naming and scope, see work instructions compared with SOPs.

Where it matters for laboratories and testing sites

For equipment documentation, WHO’s bench-aid activity gives a concrete control: attach the aid to its SOP, show the SOP version and revise and replace the aid when that SOP changes. A laminated card is still connected to a changing procedure. Its durable format does not establish that the instructions remain current.

For testing sites outside laboratories, WHO’s Pillar 5 addresses approval, obsolete-document withdrawal and the security and retrieval of records. This is a separate setting with its own examples; it is not a statement that every research laboratory has identical obligations. The useful connection is that an instruction and the evidence generated from it both need an identified place in the documentation system.

For a laboratory adapting this outline, the editorial question is therefore specific: which fields already exist in the parent process, and which must be visible on the task document? A controlled reference can avoid copying the entire parent procedure into every instruction. It still needs to identify the intended document unambiguously.

Illustrative example: revising a document-reference card

Illustrative composite: the following scenario, identifiers and role assignments are invented to demonstrate the template. They describe no real laboratory, completed validation or operating procedure. The activity is administrative document maintenance, with no testing or equipment operation.

Imagine a laboratory uses a reference card to locate its approved document register. The card points staff to the register rather than containing technical instructions. Its owner wants to replace an outdated folder reference. The proposed instruction title is “Reference-card consistency review,” with the fictional identifier WI-DOC-EXAMPLE and revision A. The purpose is a card whose document reference agrees with the authorized register.

In this composite, the scope starts with the existing card and the approved register entry. It ends with a review finding ready for the document owner. It excludes authorizing a new version, changing the parent procedure and deciding how long historical records are retained. Writing these exclusions makes the boundary visible: the person comparing two references is not automatically the person authorized to release a replacement.

The input field names the card and the relevant register entry. The responsible-user field names the fictional document coordinator. The check field asks whether the card’s identifier, document title, revision and location agree with that entry. The exception field refers a disagreement to the document owner. The completion record is the review finding, not the blank reference card.

Suppose the titles and identifiers agree, but the card points to a retired folder. The finding can identify that mismatch without asserting that the card is approved for use. In the example’s change-history field, the proposed change is limited to the folder reference; the authorization field remains uncompleted until the local approval process supplies it. That separation prevents an illustrative review outcome from masquerading as release authorization.

Now consider a different document: an equipment bench aid derived from an SOP. Apply WHO’s source-specific relationship rather than copying the independent revision scheme from this administrative example. The aid carries the SOP version and follows its revision and replacement. The comparison shows why a generic “version” box is insufficient unless the author has also defined what the version belongs to.

Common misunderstandings

A template is automatically an approved instruction. It is a starting structure. WHO’s laboratory template explicitly calls for local adaptation. A file containing an approval box has not acquired approval simply because the box exists.

Every task needs a separate one-page document. EPA’s format guidance does not prescribe one universal layout. The scope, dependencies and user need should determine the document’s content within the local system. One page is a formatting choice, not proof of completeness.

A shorter aid replaces the parent procedure. WHO’s equipment example retains the relationship with the SOP. A reminder cannot silently acquire a broader scope just because it is easier to reach.

Review means editing only the task wording. WHO’s document-control activity includes references and supporting material. In the composite above, the task wording might remain understandable while its folder reference is wrong.

One retention interval fits everything. WHO’s testing-site guidance makes archiving duration specific to the document or record. This template deliberately leaves retention to the applicable local rule rather than inventing a period.

Release checklist

Use these editorial review prompts alongside the local approval process. They turn the named guidance into questions about the completed document, rather than treating the outline as a compliance checklist.

  • Identity: can the reader identify the document and its applicable revision? This reflects the identification controls described in EPA QA/G-6.
  • Local fit: do the names, locations and responsibilities describe the actual setting? WHO’s quality-manual templates require local customization.
  • Dependencies: have references, forms and appendixes been checked together? WHO’s document-control activity includes these in review.
  • Aid relationship: if this is a WHO-style equipment bench aid, does its version agree with the parent SOP?
  • Evidence: is the resulting record distinguishable from the instruction, with a defined retrieval location and applicable control rule? This reflects WHO’s document-and-record distinction.

Sources

Data: Task-document purposes and controls across WHO and EPA guidance

An original cross-source compilation comparing the functions and controls of laboratory templates, equipment bench aids, testing-site job aids, activity checklists and records. Each row preserves the source setting; it does not assert a universal document hierarchy.

Task-document purposes and controls across WHO and EPA guidance
Document or record in source contextSource-described functionSource-described control or relationshipSource URL
Laboratory quality-manual templatesEditable starting documents for laboratory policies and proceduresCustomize the template text to the local situationhttps://www.who.int/publications/m/item/laboratory-quality-manual
Equipment bench aid in WHO LQSISimplified routine-use reminder near the equipmentInclude as SOP appendix, carry the SOP version and revise and replace on SOP revisionhttps://extranet.who.int/lqsi/content/prepare-bench-aids-each-piece-equipment-including-daily-maintenance-instructions
Job aid at a non-laboratory testing siteShort visual version of an SOPDocuments are approved before use and obsolete documents removed from circulationhttps://www.who.int/tools/quality-management-system-for-non-laboratory-settings/pillar-5-documents-and-records
Activity checklist in EPA QA/G-6Supports ordered actions and documents completed actionsReference at the point of use; checklist is part of the SOP, not the SOP itselfhttps://www.epa.gov/sites/default/files/2015-06/documents/g6-final.pdf
Record at a non-laboratory testing siteInformation or results generated from testing activitiesSecure, maintain and make retrievable; archiving duration is document- or record-specifichttps://www.who.int/tools/quality-management-system-for-non-laboratory-settings/pillar-5-documents-and-records

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Work instruction template for laboratory tasks

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →