Skip to main content
v2026.11,986 entries · CC-BY 4.0

Xylene SDS: Hazards, Flash Point, Storage and Disposal

What an xylene safety data sheet says: H226/H312/H315/H332, flash point by isomer, exposure limits compared, storage and disposal.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

A xylene safety data sheet describes a flammable liquid that is also harmful by skin contact and inhalation and irritating to skin. The usual GHS entries are H226, H312, H315 and H332 under a “Warning” signal word, and the flash point on the sheet in front of you depends on which isomer or mixture it covers: 25 °C closed cup for m- and p-xylene, 31 °C for o-xylene (PubChem compilations, read 2026-11-19). The federal OSHA exposure limit is 100 ppm as an 8-hour average, but the ACGIH value is 20 ppm, and older sheets often still print the superseded number.

What an xylene SDS covers

“Xylene” on a label can mean one of three dimethylbenzene isomers (ortho, meta, para) or a mixed-isomer product listed under CAS 1330-20-7. The OSHA Occupational Chemical Database entry, “Xylene, All Isomers (Dimethylbenzene)”, gives the formula C8H10, a molecular weight of 106.17, and describes a colorless liquid with an aromatic odor (OSHA chemical database, read 2026-11-19). Commercial lab-grade xylene is frequently a mixture, and some product sheets also list ethylbenzene as a second component, so the composition in section 3 of your sheet tells you which numbers apply.

Each manufacturer sheet follows the 16-section GHS layout, which the guide to reading a safety data sheet walks through. Sheets from different suppliers for the same CAS number are not identical: the isomer, the purity grade, the SDS version date and the classification each supplier submits can all differ. The sections below explain what the underlying public references say, so you can check the supplier sheet you hold against them rather than trusting any single document.

GHS classification and hazard statements

The aggregated notifications to the European Chemicals Agency that PubChem reproduces for all three isomers give a “Warning” signal word and four hazard statements (PubChem compound records for o-xylene, m-xylene and p-xylene, read 2026-11-19):

  • H226: flammable liquid and vapor.
  • H312: harmful in contact with skin.
  • H315: causes skin irritation.
  • H332: harmful if inhaled.

One caveat matters when you compare sheets: for m- and p-xylene, a small share of the notifications (11 of roughly 1,380 reports) state that the substance does not meet GHS criteria, so a sheet with fewer entries is not necessarily an error.

The OSHA entry lists NFPA 704 ratings of 2 for health, 3 for fire and 0 for reactivity. The site’s explainer on the NFPA 704 diamond versus GHS labels explains why that diamond and the GHS pictograms are different systems with different numbers.

Flash point and flammability by isomer

Flash point is the entry people most often look up, and it is where sheets disagree. The OSHA database gives a range of 81-90 °F (about 27-32 °C) for the all-isomers entry, while the per-isomer PubChem records give 31 °C (87.8 °F) closed cup for o-xylene from a Sigma-Aldrich SDS, and 25 °C (77 °F) closed cup for m- and p-xylene. Older NFPA and NTP figures cited in the same record show 63 °F (17 °C) for o-xylene, which is a reminder that an older reference can disagree with a current supplier sheet.

All of these values sit within the GHS flammable-liquid Category 3 band (flash point at or above 23 °C and at or below 60 °C), consistent with H226; the guide to flammable liquid Category 3 covers the threshold and the label. The data table below compares the isomer-level values side by side.

The vapor behaviour is the practical hazard. PubChem’s USCG CHRIS data gives a vapor density of 3.7 relative to air, meaning the vapor is heavier than air and can travel along a bench or floor to an ignition source and flash back. The OSHA entry lists explosive limits of 0.9-1.1% (lower) and 6.7-7.0% (upper), and the per-isomer records give 0.9-7.6 vol% for o-xylene and 1.0-7.0 vol% for the m- and p- forms. The autoignition temperature quoted for o-xylene is 463 °C (NFPA) in the same record. For fire response, CHRIS lists foam, dry chemical and carbon dioxide, and notes that water may be ineffective.

Exposure limits compared

A single number for “the xylene limit” does not exist: the agencies set different values, and the difference is the commonest source of out-of-date text on SDSs. The values below are from the OSHA chemical database entry (read 2026-11-19, page last updated 2021-04-06). For how the agencies’ limits relate to one another, see permissible exposure limits versus TLVs and RELs.

Source Limit type Value
OSHA (29 CFR 1910.1000 Table Z-1) PEL, 8-hour TWA 100 ppm (435 mg/m³)
NIOSH REL, TWA 100 ppm (435 mg/m³)
NIOSH REL, STEL 150 ppm (655 mg/m³)
ACGIH TLV, TWA [2021] 20 ppm
Cal/OSHA PEL TWA / STEL / ceiling 100 ppm / 150 ppm / 300 ppm
NIOSH IDLH 900 ppm

The ACGIH figure was 100 ppm (TWA) with a 150 ppm STEL when the PubChem record cited the 2016 values; the OSHA entry now shows 20 ppm [2021]. A sheet that still prints 100 ppm as the TLV is quoting the earlier ACGIH value, and the OSHA PEL of 100 ppm remains the legally enforceable federal figure. The OSHA entry also notes an ototoxicant (OTO) remark for p-xylene and mixtures containing it, and carcinogen classifications of IARC Group 3, ACGIH A4 and EPA category I.

If your lab needs to measure exposure rather than quote a limit, the OSHA entry names two validated methods: OSHA Method 5000 (a charcoal sorbent tube, 12 L sampled at 0.05 L/min over 240 minutes) and OSHA Method 1002 (a passive sampler), both analysed by gas chromatography with flame ionization detection. It also lists Gastec 123 and Matheson-Kitagawa 8014-143SA detector tubes for on-site screening.

Storage and incompatible materials

The storage guidance that appears on supplier sheets is consistent with the public references. The International Chemical Safety Card text compiled in PubChem calls for fireproof storage in the original container, separated from strong oxidants and strong acids, in an area without drain or sewer access. NIOSH Pocket Guide data in the same records lists strong oxidizers and strong acids as incompatible. The Sigma-Aldrich o-xylene sheet (version 5.5, 2016-06-02, as reproduced in PubChem) adds that the container should be kept tightly closed in a dry, well-ventilated place, that opened containers must be carefully resealed and kept upright, and it gives the German storage class (TRGS 510) for flammable liquids.

In lab terms, that places xylene in the flammables group. The site’s guides on flammable liquid storage cabinets and on chemical storage compatibility and segregation cover the cabinet and segregation mechanics. If your sheet gives a different storage class from the one above, follow the sheet and your institution’s chemical hygiene plan.

Disposal

The Sigma-Aldrich sheet reproduced in PubChem directs xylene to a licensed professional waste disposal service, describes incineration in a chemical incinerator with an afterburner and scrubber (with extra care in igniting because the material is highly flammable), and says contaminated packaging is treated as unused product. In the United States, the same record notes that the EPA hazardous waste numbers U239 and F003 apply to xylene waste, and that generators of 100 kg or more per month must follow EPA storage, transport, treatment and disposal rules. The site’s guides to RCRA hazardous waste codes and lab waste disposal explain how those codes are assigned in practice. Your own institution’s waste program, not the SDS alone, decides the container and pickup process.

Health effects described in the references

CHRIS, as quoted in PubChem, states that vapors cause headache and dizziness, that the liquid irritates eyes and skin, and that liquid aspirated into the lungs causes severe coughing, distress and pulmonary edema. This is general hazard information drawn from the references; it is not medical advice, and anyone exposed should follow their facility’s emergency procedure and the first-aid section of the sheet they hold.

Checking your sheet: an SDS-section-to-action list

  • Section 2 (hazards): confirm H226, H312, H315 and H332 are present.
  • Section 3 (composition): identify the isomer or mixture, because it decides which flash point applies.
  • Section 7 (handling and storage): expect flammable-liquid storage, away from oxidizers and strong acids, in the original container.
  • Section 8 (exposure controls): compare the printed limits with the table above; a 100 ppm ACGIH figure is the pre-2021 value.
  • Section 9 (properties): compare the flash point with the data table below, using the closed-cup value for the exact isomer.
  • Section 10 (stability): check the incompatibility line names strong oxidizers.
  • Section 13 (disposal): treat it as flammable hazardous waste and check that your waste program lists U239 or F003 as relevant.

Common misunderstandings

“Xylene has one flash point.” It does not: the value depends on the isomer or mixture, and older sources differ from current supplier sheets (see above). “The TLV is 100 ppm.” That was the ACGIH value in 2016; the OSHA entry now shows 20 ppm [2021], while 100 ppm is the OSHA PEL. “A sheet with only some H-codes is wrong.” Classifications are notified by each supplier, and a minority of notifications for m- and p-xylene report no GHS classification. “Xylene and its substitutes share a sheet.” Replacement clearing agents have their own sheets and hazards; see xylene substitutes, xylene boiling point and the para-xylene guide for production and uses. For comparable solvent sheets, see toluene SDS and benzene SDS.

Sources

Data: Xylene isomers: flash point, boiling point, explosive limits and vapor pressure

Side-by-side physical and flammability values for o-, m- and p-xylene compiled from the PubChem compound records (citing a Sigma-Aldrich SDS, NFPA and ICSC data) and the OSHA Occupational Chemical Database entry for xylene, read 2026-11-19.

Period covered: 2016/2021.

Xylene isomers: flash point, boiling point, explosive limits and vapor pressure
IsomerFlash point, closed cup (°C)Boiling point (°C)Lower explosive limit (vol%)Upper explosive limit (vol%)Vapor pressure (mmHg)
o-xylene31144.50.97.67
m-xylene25139.1179
p-xylene25138.3179

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Xylene SDS: Hazards, Flash Point, Storage and Disposal

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →