Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop acapella aerobika supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Direct comparison

Acapella vs Aerobika: Cleaning and Replacement

Acapella vs Aerobika compared from ICU Medical, Monaghan and FDA documents: cleaning methods, 6- vs 12-month replacement, what each forbids.

Written and maintained by CASRAI Editorial Board

Last updated

How do Acapella Choice Blue (ICU Medical) and Aerobika (Trudell Medical International) compare side by side?

The table below compares Acapella Choice Blue (ICU Medical) and Aerobika (Trudell Medical International) across 11 dimensions, from device class to when each applies.

Side-by-side comparison

DimensionAcapella Choice Blue (ICU Medical)Aerobika (Trudell Medical International)
Device classDescribed by ICU Medical as a vibratory PEP therapy system, a type of oscillating positive expiratory pressure (OPEP) device.Described in its FDA 510(k) summary as an Oscillating Positive Expiratory Pressure (PEP) device, mechanically driven only by the energy of the exhaled breath.
Regulatory link between the twoThe Acapella (510(k) K002768) is the device FDA named as the equivalent when it cleared the original Aerobika.FDA records that the original Aerobika OPEP (K123400, product code BWF, regulation 21 CFR 868.5690) was found substantially equivalent to the Acapella (K002768).
Parts the manufacturer says to cleanFour: mouthpiece, base unit (with frequency adjustment dial), cover, and rocker assembly. The rocker arm must not be separated from its platform base.The FDA 510(k) summary states the device can be disassembled for cleaning. On the manometer version, the pressure indicator is not intended to be cleaned.
Soap and waterSoak base unit, cover and rocker in 2 tablespoons (30 mL) of mild dish detergent per gallon (3785 mL) of water for 10 minutes, rinse under running water for 30 seconds, air dry.Listed by the distributor as an approved cleaning method ("soap and water"). The page gives no detergent ratio or soak time.
DishwasherPermitted in a home dishwasher that is NSF/ANSI 184 certified, run on a sanitization setting with parts on the top shelf.Listed as an approved cleaning method ("top rack dishwasher").
Alcohol soakCompatible with 70% isopropyl alcohol: soak 5 minutes, twice daily, then rinse with sterile water.70% isopropyl alcohol soak for 5 minutes.
BoilingBoil the cleaned device in distilled water for 5 minutes, let it cool, and air dry.Boiling for 5 minutes.
Other disinfection routes and prohibitionsDo not use bleach. Do not microwave.3% hydrogen peroxide soak for 30 minutes, or a microwave steam bag used according to that bag maker's instructions.
Stated replacement intervalDiscard after 6 months of use; clean and sanitize weekly if necessary (Acapella Choice Blue sheet).Recommended replacement period of 12 months (distributor page).
Mouthpiece or maskThe cleaning sheet lists a detachable mouthpiece as one of the four parts.The distributor does not recommend use with a mask and recommends a mouthpiece, because the person would have to hold both mask and device during the session.
When each appliesApplies when a clinician has prescribed or supplied an Acapella and you are following the instructions for that exact model. The 6-month limit and the no-bleach, no-microwave rules come from the Choice Blue sheet and should not be carried over to other models.Applies when a clinician has prescribed or supplied an Aerobika. Cleaning and replacement guidance on this page is the distributor's summary; the Instructions for Use that came with the device govern.

Sources

Ask CASRAI · free to try

Ask about Acapella vs Aerobika: Cleaning and Replacement

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Common questions

Common questions about Acapella Choice Blue (ICU Medical) vs Aerobika (Trudell Medical International)

Is Aerobika or Acapella better?

+

None of the manufacturer or FDA documents read for this page ranks one over the other. Both are OPEP devices, and FDA cleared the Aerobika by comparison with the Acapella. Which one suits a person is a question for the clinician or respiratory therapist who prescribes it.

What is the difference between Acapella and Aerobika cleaning?

+

Both allow soap and water or a dishwasher, and both list a 5-minute 70% isopropyl alcohol soak and a 5-minute boil. The Aerobika distributor also lists a 30-minute 3% hydrogen peroxide soak and a microwave steam bag; the Acapella Choice Blue sheet says not to microwave and not to use bleach.

How often do you replace an Acapella or an Aerobika?

+

The Acapella Choice Blue cleaning sheet says to discard the device after 6 months of use. The Aerobika distributor page gives a recommended replacement period of 12 months. Check the Instructions for Use for your model, because intervals can differ by model and revision.

Can you use an Aerobika with a mask?

+

The Aerobika distributor does not recommend use with a mask and recommends a mouthpiece, since the person would have to hold the mask and the device for the whole session.

Are Acapella and Aerobika the same type of device?

+

Yes in class. FDA 510(k) K150173 describes the Aerobika as an Oscillating Positive Expiratory Pressure device, and ICU Medical describes the Acapella Choice Blue as a vibratory PEP therapy system.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →