CPAP Machine Maintenance: Cleaning Schedule and Replacement Intervals

CPAP machine maintenance: cleaning schedule, manufacturer replacement intervals, and what the FDA says not to use to clean a CPAP machine.

Written and maintained by CASRAI Editorial Board

Published

This page describes products and general use; it is not medical advice.

On this page

Who uses this: people who use a CPAP machine at home, and clinic, sleep-service and home-medical-equipment staff who explain upkeep at handover. After reading, you should know what the routine covers, how often each part is cleaned or replaced according to named manufacturer guidance, and what the FDA says not to use.

What CPAP machine maintenance covers

CPAP maintenance is the routine cleaning, inspection and scheduled replacement of the parts of a continuous positive airway pressure system: the mask and cushion, headgear, air tubing, humidifier tub, air filter and the device itself. A CPAP machine delivers pressurised room air through tubing to a mask (see what a CPAP machine is and how it works), so every part that touches air or moisture is on the schedule. Exact intervals come from the manufacturer’s user guide for your device; the tables below attribute each interval to the guide it came from rather than blending them.

Cleaning schedule

The ResMed summary guide Looking after your CPAP gear (revision 2025-01, read 2026-11-07) sets this routine for ResMed products. It points readers to the relevant product user guide for detail.

Frequency What to clean or check (ResMed guide)
Daily Mask tubing/elbow and cushions
Weekly Mask frame and headgear; device air tubing; humidifier tub; wipe the device
Monthly Check the air filter for dust; inspect the humidifier tub (replace if leaking, cracked, cloudy or pitted)

The Philips DreamStation 2 user manual (20250630 edition) likewise says to hand wash the tubing before first use and weekly. See also CPAP hose sizes and care.

How to clean a CPAP machine

The U.S. Food and Drug Administration consumer update “Do you need a device that claims to clean your CPAP machine?” (content current 2024-08-26, read 2026-11-07) states that most CPAP accessories, such as hoses or tubes and masks, can be cleaned with only mild soap and water, and that some manufacturers suggest diluted vinegar.

The device itself

The FDA says not to submerge a unit that has an electrical cord. Wipe the exterior with a damp towel.

Humidifier tub

Clean it as the manual describes. ResMed’s guide says to wash it in warm water with mild detergent and dry it out of direct sunlight.

Mask and cushion

ResMed’s guide says to wash by hand with mild detergent at about 30 °C (86 °F), rinse with drinking-quality water and air dry out of direct sunlight, and to wash the face before putting the mask on and keep moisturisers away from the seal area. Memory-foam cushions (AirTouch) cannot be washed or submerged; the guide says to wipe them after each use with an alcohol-free wipe.

Air filter

Filters are replaced or cleaned on the manufacturer’s schedule. ResMed notes that a blocked filter can reduce the air pressure delivered. See CPAP disposable filters.

Replacement intervals (ResMed guideline)

ResMed gives these as guidelines for its own products, based on general wear and tear. Other manufacturers publish different figures, so use the guide supplied with your device.

Part ResMed replacement guideline
Memory-foam cushions Monthly
Machine filters 2 months
Silicone cushions, nasal pillows, fabric cushions, headgear 6 months
Standard HumidAir tub 6 months
Air tubing, mask system, cleanable HumidAir tub 12 months

For comparison, the Philips DreamStation 2 manual lists a 6-month replacement for its tubing. The difference shows why intervals should not be copied between brands. Accessory ranges are covered in CPAP accessories.

What not to use

  • Cleaning or sanitising devices. The FDA states there are currently no FDA cleared or approved devices for cleaning, disinfecting or sanitising CPAP machines. The only authorised device is an add-on that reduces bacteria on certain masks and hoses and does not replace regular cleaning.
  • UV and ozone. The FDA says these can break down hoses and masks, and that ozone can leak into the home and remain above safe limits inside the equipment for hours afterwards. It cites reports of asthma attacks, headaches and breathlessness.
  • Harsh or scented products. ResMed’s guide says to avoid aromatic solutions and scented oils, antibacterial soaps, alcohol, bleach and other strong-smelling products on mask parts.

Common mistakes

  • Submerging the machine or washing a foam cushion that the manufacturer says to wipe only.
  • Using bleach, alcohol or antibacterial soap on the mask.
  • Relying on a sanitiser that is not FDA cleared.
  • Applying one brand’s replacement intervals to another brand’s parts.
  • Drying parts in direct sunlight.

For clinic and equipment staff

When handing over or taking back a unit, the manufacturer’s user guide for that model is the reference for cleaning and replacement. Our guide to selling a used CPAP machine covers cleaning before handover.

FAQ

What is a CPAP machine?

A CPAP (continuous positive airway pressure) machine is a device that blows pressurised air through tubing and a mask. It is most often used for sleep apnea. See the full explainer.

How does a CPAP machine work?

A motor draws in room air, filters it, optionally humidifies it, and delivers it at a set pressure through the hose to the mask. That path is why the filter, humidifier tub, tubing and mask are the maintained parts.

What does a CPAP machine do?

It supplies a steady stream of air pressure through a mask, as prescribed for the user. Maintenance keeps that air path clean and the parts sealing properly.

How do I clean a CPAP machine?

Per the FDA, clean masks and hoses with mild soap and water, wipe the machine exterior with a damp towel without submerging it, and clean the humidifier tank as the manual describes. See the cleaning section above.

Sources

  • U.S. FDA, “Do you need a device that claims to clean your CPAP machine?”, consumer update, content current 2024-08-26. fda.gov (read 2026-11-07)
  • ResMed, Looking after your CPAP gear, rev. 2025-01. resmed.com.au (read 2026-11-07)
  • Philips, DreamStation 2 user manual, 20250630 edition (read 2026-10-30)

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about CPAP Machine Maintenance: Cleaning Schedule and Replacement Intervals

Ask your first 2 questions free below. Subscribers get 150 a day for $29 a month.

An AI assistant specialized in research administration. It cites the sources behind every answer, labels web answers and says when it can't answer.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →