Dobhoff vs Salem Sump: Feeding vs Sump Tube

Dobhoff vs Salem Sump: how a feeding tube and a dual-lumen sump tube differ in lumens, vent and sizes, plus the FDA Class 2 recall record. Not medical advice.

Written and maintained by CASRAI Editorial Board

Last updated

How do Dobhoff-type feeding tube and Salem Sump tube compare side by side?

The table below compares Dobhoff-type feeding tube and Salem Sump tube across 10 dimensions, from tube family to when to pick each.

Side-by-side comparison

DimensionDobhoff-type feeding tubeSalem Sump tube
Tube familySmall-bore, weighted-tip feeding tube used with a stylet (Dobhoff-type).Dual-lumen stomach tube with a separate air vent (sump).
Intended use stated by sourceFDA's device database (GUDID) describes the CORFLO Enteral Feeding Tube as a "Feeding tube with ENFit connectors 7 gm weight and stylet". Avanos markets CORFLO NG/NI feeding tubes.Peer-reviewed paper: "the manufacturer of Salem Sump tubes does not approve the use of these tubes for enteral nutrition." FDA's recall record lists suction as one of its two lumens.
LumensThe listing describes a feeding tube and stylet; no vent lumen is mentioned.Two: a larger infusion lumen and a smaller air vent that remains plugged during feeding (paper). FDA names a blue sump vent lumen and a suction lumen.
Sizes in the records10 Fr x 43 in (109 cm) and 12 Fr x 43 in (109 cm) CORFLO listings in GUDID.6 Fr to 18 Fr, coiled and standard (FDA recall record).
BoreSized by the tube's own gauge (10 or 12 Fr in the listings).The paper reports a large external diameter with a small-bore infusion channel; a 16 Fr Salem Sump infusion channel is no greater than a 12 Fr single-lumen NG tube.
Connector and accessoryENFit connectors (GUDID description).An anti-reflux valve (ARV): blue end into the blue sump vent lumen, white end into the suction lumen (FDA record).
FDA recall recordNot covered by the Salem Sump record. Recall status is looked up per model and catalog number in FDA's database.Class 2 recall of all lots, Cardinal Health 200, LLC. Cause: complaints that the ARV breaks when excessive force is applied; FDA attributes it to use error. Firm-initiated 2025-09-18, posted 2025-10-17.
FDA product code and regulationProduct code KNT (gastrointestinal tubes). 21 CFR 876.5980 covers feeding tubes.Product code KNT. 21 CFR 876.5980 lists double lumen tubes for intestinal decompression and irrigation and aspiration catheters. The regulation names neither brand.
Documents to ask the supplier forCurrent instructions for use for the exact model and catalog number, and its FDA recall status.Current instructions for use for the exact model, and confirmation that the catalog number is not in the FDA recall record.
When to pick eachChoose the tube family whose manufacturer states feeding as its intended use (the Dobhoff-type feeding tube).Choose a sump tube only where its instructions state the use you need; the manufacturer does not approve it for enteral nutrition.

Sources

  • FDA openFDA/AccessGUDID device records for CORFLO (read 2026-11-02)
  • Avanos enteral feeding page (read 2026-11-02)
  • 21 CFR 876.5980 (eCFR, read 2026-11-02)
  • FDA recall record RES 216043 (read 2026-11-02)
  • Proc (Bayl Univ Med Cent) 2021
  • 34(5):560-565, PMC8366925 (read 2026-11-02)
  • 21 CFR 876.5980 (eCFR)

Ask CASRAI · free to try

Ask about Dobhoff vs Salem Sump: Feeding vs Sump Tube

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →