Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop glass plastic supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Direct comparison

Glass vs Plastic Lab Containers: Autoclave, Seals

Glass vs plastic for lab and medical-supply containers: autoclaving by glass type, permeation and the closure seal, and adsorption, from DWK and FDA sources.

Written and maintained by CASRAI Editorial Board

Last updated

How do Glass and Plastic compare side by side?

The table below compares Glass and Plastic across 10 dimensions, from what the container is part of to when to pick each.

Side-by-side comparison

DimensionGlassPlastic
What the container is part ofOne component of a container closure system, defined by FDA as the sum of packaging components that together contain and protect the product.The same: a plastic container is judged together with its closure, not alone.
Permeation of water vapour and gasesGlass is relatively impermeable, so protection through the wall is high.FDA guidance says plastic containers are susceptible to permeation both through the container wall (its example is a low density polyethylene bottle) and by diffusion past a seal.
Role of the closure sealFDA: glass containers are more effective only if there is a good seal between the container and the closure.Seal quality matters here too, and plastic adds wall permeation on top of it.
AutoclavingDWK: borosilicate glass bottles are safe to autoclave because of very good resistance to thermal shock. Soda lime or flint glass bottles carry a much higher risk of breakage.Autoclave suitability depends on the polymer; use the manufacturer's stated rating for the specific container.
Plastic-coated glass bottlesDWK: can be autoclaved, but the coating is subject to hydrolysis by steam, so they withstand fewer autoclave cycles than uncoated glass bottles.Not applicable: this is a glass bottle with a plastic coating, not a plastic bottle.
Loading glass bottles for steam sterilisationDWK: fill typically not beyond 75% of nominal capacity (aqueous buffers may reach the nominal fill line; agar-based media only to 50%). Screw caps loosely fitted, at most one turn.Follow the manufacturer's instructions for the specific container and cap.
Surface damage and replacementDWK: strength of borosilicate 3.3 lies in the surface, and scratches greatly reduce it. It is impossible to predict when an older bottle might fail, so DWK recommends routine replacement and visual inspection for scratches or chips before use.FDA lists brittleness of a packaging component among the interactions to evaluate for plastic and other components.
Interaction with the contentsFDA lists the interactions to consider for any packaging: loss of potency by absorption or adsorption, degradation induced by a chemical leached from a component, pH change, and discoloration.The same list applies. FDA advises an extraction profile for elastomeric or plastic components.
Evidence FDA treats as sufficientFDA: for a glass component, data from USP Containers: Chemical Resistance - Glass Containers will typically be considered sufficient evidence of safety and compatibility (some cases, such as chelating agents, may need additional criteria).FDA expects extraction data for plastic components rather than a single compendial glass test. This is drug-packaging guidance from 1999, not a rule for laboratory bottles.
When to pick eachBorosilicate glass when containers are steam-sterilised repeatedly or low permeation matters, provided the closure seals well and the bottle is inspected and replaced routinely.Plastic when the manufacturer's rating for that polymer covers your sterilisation and chemical conditions and wall permeation is acceptable for the contents.

Ask CASRAI · free to try

Ask about Glass vs Plastic Lab Containers: Autoclave, Seals

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Common questions

Common questions about Glass vs Plastic

Is glass or plastic better for lab storage?

+

It depends on the conditions. FDA guidance says glass is relatively impermeable but more effective than plastic only if the seal between container and closure is good, while plastic containers are permeable through the wall and past a seal. Repeated steam sterilisation favours borosilicate glass; for plastic, check the manufacturer's rating for the specific polymer.

Can you autoclave plastic bottles?

+

Whether a plastic bottle can be autoclaved depends on the polymer and the manufacturer's rating, so check that rating for the specific container before sterilising. Borosilicate glass bottles, by contrast, are described by DWK Life Sciences as safe to autoclave.

Can you autoclave glass bottles?

+

Borosilicate glass bottles can be, because of their resistance to thermal shock, according to DWK Life Sciences (2022). Soda lime or flint glass bottles carry a much higher risk of breakage. Fill them to no more than about 75% of nominal capacity (50% for agar-based media) and fit screw caps loosely, at most one turn.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →