How do Hyperbolic (Michaelis-Menten, Hill slope 1.0) and Sigmoidal (Hill slope above 1.0, or log X axis) compare side by side?

The table below compares Hyperbolic (Michaelis-Menten, Hill slope 1.0) and Sigmoidal (Hill slope above 1.0, or log X axis) across 11 dimensions, from equation used in prism to when to pick each.

Side-by-side comparison

DimensionHyperbolic (Michaelis-Menten, Hill slope 1.0)Sigmoidal (Hill slope above 1.0, or log X axis)
Equation used in PrismMichaelis-Menten: Y = Vmax*X/(Km + X). Vmax is the maximum velocity in the units of Y; Km is the substrate concentration giving half-maximum velocity, in the units of X.Allosteric enzyme form: Y = Vmax*X^h/(Khalf^h + X^h), where h is the Hill slope. Dose-response form on a log axis: Y = Bottom + (Top - Bottom)/(1 + 10^((LogEC50 - X)*HillSlope)).
Shape of the curveRises steeply at low X and flattens toward Vmax: a hyperbola on a linear X axis. GraphPad states that a system following mass-action kinetics has a hyperbolic dose-response relationship.S-shaped. Prism describes the standard log-dose fit as the familiar symmetrical sigmoidal shape. In the allosteric model the velocity-versus-substrate curve appears sigmoidal when h is above 1.0.
Role of the Hill slopeh = 1. Prism states that when h = 1 the allosteric equation is identical to the standard Michaelis-Menten equation. A dose-response curve with a standard slope has a Hill slope of 1.0.h above 1.0 gives a steeper curve; Prism calls the Hill slope an empirical measure of steepness and of the presence of cooperativity, and says the curve is sigmoidal due to positive cooperativity when it exceeds 1.0.
X axisLinear substrate or ligand concentration for the Michaelis-Menten form.Logarithm of dose or concentration for the dose-response form. Prism says that if concentrations are entered raw, it can transform X to logs. In the allosteric form, X is a linear substrate concentration.
The same data, drawn both waysMass-action response plotted against linear dose is hyperbolic.The same mass-action response becomes sigmoidal only when plotted against the logarithm of dose. A log axis therefore changes the look of the curve without changing the underlying Hill slope of 1.0.
Parameters you reportVmax and Km. Prism notes Vmax is extrapolated to very high substrate, so it is usually higher than any velocity actually measured.Top, Bottom, LogEC50 and, when fitted, the Hill slope. In the allosteric form: Vmax, Khalf and h.
Fitting choiceUse nonlinear regression on substrate versus velocity. Prism recommends the Lineweaver-Burk reciprocal plot only for display, because the reciprocal transformation distorts experimental error.Prism says a Hill slope of 1.0 is standard and you should consider constraining it to 1.0. The variable-slope fit is preferable when you have plenty of data points.
Worked arithmetic: spread of 10% to 90% responseWith h = 1, a response of 10% of maximum needs X = Khalf/9 and 90% needs X = 9*Khalf, a span of 81-fold in concentration (1.91 log10 units). This is derived from the equations above.With h = 2 the same span is 81^(1/2) = 9-fold (0.95 log10 units); with h = 3 it is about 4.3-fold. The higher the Hill slope, the narrower the concentration window the curve spends between 10% and 90%.
Midpoint parameterKm, the substrate concentration needed to achieve half-maximum enzyme velocity, in the same units as X. At X = Km the equation gives Y = Vmax/2, since Km/(Km + Km) = 1/2.LogEC50 in the dose-response form and Khalf in the allosteric form. At X = Khalf the allosteric equation gives Y = Vmax/2 for any h, so the midpoint keeps its meaning whatever the slope; only the steepness around it changes.
Typical laboratory useEnzyme velocity versus substrate concentration when the enzyme shows no cooperativity; saturation binding drawn on a linear ligand axis.Dose-response and concentration-response experiments summarised by an EC50 or IC50; allosteric enzymes whose velocity curve is S-shaped on a linear substrate axis.
When to pick eachPick it when the Hill slope can be held at 1.0 and the question is Km and Vmax from a linear-axis curve.Pick it for log-dose responses, or when the Hill slope departs from 1.0 and you have enough data points to fit it as a free parameter.

Ask CASRAI · full access

Ask about Hyperbolic vs Sigmoidal Curves: Hill Slope & Fit

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Common questions

Common questions about Hyperbolic (Michaelis-Menten, Hill slope 1.0) vs Sigmoidal (Hill slope above 1.0, or log X axis)

Is a hyperbolic curve the same as a sigmoidal curve?

+

No, but they can describe the same relationship. GraphPad states that a mass-action system has a hyperbolic dose-response relationship that becomes sigmoidal only when response is plotted against the logarithm of dose. The shapes differ because of the axis, not because the biology differs.

What Hill slope makes a curve hyperbolic?

+

A Hill slope of 1.0. In the GraphPad allosteric enzyme equation, Y = Vmax*X^h/(Khalf^h + X^h), h = 1 reduces to the standard Michaelis-Menten equation, which is hyperbolic on a linear substrate axis.

Why does a dose-response curve look sigmoidal?

+

Because X is a logarithm of dose or concentration. Prism's log-dose equation gives the familiar symmetrical sigmoidal shape, and Prism can transform raw concentrations to logs before fitting.

When is a curve sigmoidal on a linear concentration axis?

+

When the Hill slope h is above 1.0. GraphPad describes the allosteric enzyme curve as sigmoidal due to positive cooperativity in that case, and calls h an empirical measure of steepness and of the presence of cooperativity.

Should I fix the Hill slope at 1.0 or let it vary?

+

Prism says 1.0 is the standard slope and you should consider constraining it to 1.0. It says the variable-slope fit, which estimates the Hill slope from the data, is preferable when you have plenty of data points.

Can I get Km and Vmax from a Lineweaver-Burk plot?

+

Prism advises against it. The reciprocal transformation distorts experimental error, so the guide recommends nonlinear regression on substrate versus velocity and the reciprocal plot for display only.

What if my data are already sigmoidal before I take logs?

+

GraphPad notes that users occasionally find dose-response data sigmoidal before log transformation and says Prism has a built-in equation for that situation. The log-dose model described above does not assume that shape.

Does the midpoint change meaning when the Hill slope changes?

+

No. In the Prism allosteric equation, Y = Vmax*X^h/(Khalf^h + X^h), substituting X = Khalf gives Y = Vmax/2 for every value of h. The Hill slope changes how steeply the response climbs around that midpoint, not where the midpoint sits. With h = 1 the midpoint is the Michaelis-Menten Km.

Data: Concentration span between 10% and 90% of maximal response by Hill slope

Computed from the Hill-type equation Y = Vmax*X^h/(Khalf^h + X^h) and the log-dose logistic form in the GraphPad Prism guides. At 10% and 90% of maximal response X^h equals Khalf^h/9 and 9*Khalf^h, so the fold span in concentration is 81^(1/h). Values are derived arithmetic, not measured data.

Concentration span between 10% and 90% of maximal response by Hill slope
Hill slope (h)Fold span in concentration, 10% to 90% (fold)Span in log10 units (log10)Curve description
0.565613.82Shallower than standard: very wide concentration window
1811.91Standard slope; Michaelis-Menten/mass action; hyperbolic on a linear X axis
290.95Steeper; sigmoidal on a linear X axis (positive cooperativity in the allosteric model)
34.330.64Steeper still; narrow concentration window

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →