In summary
Liquid nitrogen and dry ice are different substances, and dry ice is not liquid nitrogen. Liquid nitrogen is a boiling cryogenic liquid at 77.34 K (about -195.8 C); dry ice is solid carbon dioxide that sublimes at about -78.5 C at atmospheric pressure. Both can cause cold burns and displace oxygen, but liquid nitrogen adds dewar over-pressure and oxygen-condensation risks and needs a face shield for dewar filling. Neither belongs in a cold room. Pick the control set that matches the material in your hands, as the table below shows.
How do Liquid nitrogen and Dry ice compare side by side?
The table below compares Liquid nitrogen and Dry ice across 12 dimensions, from what it is to when each applies.
Side-by-side comparison
| Dimension | Liquid nitrogen | Dry ice |
|---|---|---|
| What it is | Nitrogen (N2) held as a boiling liquid. It is a cryogenic liquid, and the University of Pennsylvania SOP names liquid nitrogen and liquid helium as the most common laboratory cryogens. | Solid carbon dioxide (CO2). It is a different substance from nitrogen, so dry ice is not liquid nitrogen and neither can be converted into the other. |
| Phase behaviour at normal pressure | NIST gives the normal boiling point of nitrogen as 77.34 K, so at atmospheric pressure it exists as a liquid that boils and releases nitrogen gas. | NIST gives the carbon dioxide triple point as 216.58 K (-56.57 C) at 5.185 bar. Atmospheric pressure is below that triple-point pressure, so there is no liquid phase: the solid sublimes straight to gas. |
| Temperature | 77.34 K, which is about -195.8 C (the NIST boiling point converted to Celsius). | The Pennsylvania SOP states that dry ice sublimates from a solid to a gas at temperatures above -78.5 C at atmospheric pressure. |
| How the sources classify it | The Pennsylvania SOP describes cryogens as boiling typically below 123 K (-150 C); Nevada Reno defines a cryogenic liquid as one with a boiling point below -100 F (-73 C). Liquid nitrogen falls under both. | Dry ice is covered in the same Pennsylvania SOP as liquid cryogens, with its own PPE and storage lines, but it is a solid that sublimes rather than a cryogenic liquid under the Reno definition. |
| Gas released and expansion | Nevada Reno states that one volume of liquid nitrogen vaporizes to 694 volumes of nitrogen gas. | The sources read give no expansion ratio for dry ice, so none is stated here. Both materials release gas as they warm, and Pennsylvania notes the gases are colorless and odorless. |
| Main hazards | Pennsylvania lists burns and frostbite, asphyxiation, liquid oxygen formation (for boiling points below -183 C) and dewar over-pressure. Nevada Reno adds that liquid nitrogen can condense atmospheric oxygen, producing an oxygen-enriched liquid. | Pennsylvania lists the cold-contact and asphyxiation hazards for dry ice with the other cryogens. Its boiling-point threshold for liquid oxygen formation, below -183 C, is not reached at -78.5 C. |
| Protective equipment | For filling a dewar: cryo-gloves, face shield, safety glasses, lab coat, long pants and enclosed shoes. Cryo-gloves are for short-term contact only; nitrile, leather, heat-resistant and autoclave gloves do not protect. | The same list without the face shield (Pennsylvania). Nevada Reno's general cryogen PPE is heavy loose-fitting gloves, safety glasses, a face shield and an apron. |
| Containers and sealing | Never seal a cryogen in a closed container; no Styrofoam or thermos-type vessels. Nevada Reno says to fill cryogen containers no more than 80 percent and notes that sealed warming builds pressure. Do not pull, push or roll a dewar: use a cart. | Dry-ice and alcohol baths are kept open to the atmosphere (Nevada Reno). Pennsylvania's rule against sealing applies to cryogens in general, so a sealed container is a pressure hazard whenever a solid or liquid is warming inside it. |
| Cold rooms and enclosed spaces | Pennsylvania: no cryogens in rooms with recirculating exhaust, such as cold rooms. Nevada Reno: refrigerated rooms recirculate air and can reach dangerous atmospheres from liquid nitrogen or dry ice. | Pennsylvania: do not work with or store dry ice in cold rooms. Nevada Reno names dry ice alongside liquid nitrogen as a cause of dangerous atmospheres in recirculating rooms. |
| Oxygen monitoring | Nevada Reno: a room where a cryogen could lower oxygen below 20 percent needs a continuous oxygen monitor with an alarm. Pennsylvania notes oxygen monitors must be approved by EHRS. | The monitoring rule is written for cryogen releases in general; the gas from sublimating dry ice is also colorless and odorless, so the same room-level concern is in the sources. |
| Transport | Dewars are moved on a cart, never rolled or pushed (Pennsylvania). | Pennsylvania states that dry ice shipments require training and special packaging; the shipping rules themselves are not summarised here. |
| When each applies | Choose the liquid-nitrogen safety controls when the material is a boiling cryogenic liquid at 77.34 K: face shield, no sealed containers, cart transport, oxygen monitoring where a release could lower oxygen, and no recirculating-air rooms. | Choose the dry-ice controls when the material is solid CO2 subliming at about -78.5 C: cryo-gloves and eye protection, no sealed containers, no cold-room work or storage, and the shipping training and packaging the Pennsylvania SOP requires. |
Sources
- NIST Chemistry WebBook, nitrogen (webbook.nist.gov/cgi/cbook.cgi?ID=C7727379&Mask=4)
- NIST Chemistry WebBook, carbon dioxide (webbook.nist.gov/cgi/cbook.cgi?ID=C124389&Mask=4)
- University of Pennsylvania EHRS, SOP: Cryogens and Dry Ice (https://ehrs.upenn.edu/health-safety/lab-safety/chemical-hygiene-plan/standard-operating-procedures/sop-cryogens-and-dry)
- University of Nevada, Reno EHS, Chemical Hygiene Plan chapter 8 (https://www.unr.edu/ehs/safety-policies-and-manuals/chemical-hygiene-plan/chapter-8). Read 2026-11-17
- Same sources as the first column
Common questions
Common questions about Liquid nitrogen vs Dry ice
Is dry ice liquid nitrogen?
+
No. Dry ice is solid carbon dioxide, which sublimes straight to gas at about -78.5 C at atmospheric pressure. Liquid nitrogen is nitrogen held as a boiling liquid at 77.34 K, about -195.8 C. They are different chemical substances at very different temperatures.
Why does dry ice not melt into a liquid?
+
NIST lists the carbon dioxide triple point at 5.185 bar. Atmospheric pressure is lower, so solid CO2 passes directly to gas without a liquid stage.
Does liquid nitrogen need a face shield but dry ice not?
+
For filling a dewar, the University of Pennsylvania SOP lists cryo-gloves, a face shield, safety glasses, a lab coat, long pants and enclosed shoes. For dry ice it lists the same equipment without the face shield. The SOP states cryo-gloves are for short-term contact only, and that nitrile, leather, heat-resistant and autoclave gloves do not protect.
Can liquid nitrogen create an oxygen-enriched liquid?
+
Nevada Reno states that liquid nitrogen can condense atmospheric oxygen, and the Pennsylvania SOP lists liquid oxygen formation as a hazard for cryogens with boiling points below -183 C. Liquid nitrogen at about -195.8 C is below that threshold; dry ice at about -78.5 C is not.
Can you store dry ice or liquid nitrogen in a cold room?
+
The University of Pennsylvania SOP says not to store or work with dry ice in cold rooms and not to use cryogens in rooms with recirculating exhaust. Nevada Reno also warns that recirculating air in refrigerated rooms can reach dangerous atmospheres.
Data: Liquid nitrogen and dry ice: laboratory hazard controls compared
Compares five handling controls and hazards for liquid nitrogen and dry ice in laboratories, compiled from the University of Pennsylvania EHRS cryogens and dry ice SOP, the University of Nevada Reno chemical hygiene plan chapter 8 and NIST Chemistry WebBook phase data. Each cell restates what the cited university procedure states for that material.
| Control or hazard | Liquid nitrogen | Dry ice |
|---|---|---|
| Face shield for filling or handling | Required with cryo-gloves, safety glasses, lab coat, long pants and enclosed shoes (dewar filling) | Same PPE without the face shield |
| Use in a cold room | Not allowed: no cryogens in recirculating-exhaust rooms | Not allowed: do not work with or store dry ice in cold rooms |
| Gas hazard | Nitrogen gas, colorless and odorless; one volume of liquid gives 694 volumes of gas | Carbon dioxide gas, colorless and odorless; asphyxiation hazard |
| Sealed containers | Never seal; sealed warming builds pressure; fill to no more than 80 percent | Dry ice and alcohol baths are open to the atmosphere |
| Boiling point below -183 C (liquid oxygen formation risk) | Yes: about -195.8 C | No: sublimes at about -78.5 C |
Sources
- NIST Chemistry WebBook: nitrogen (accessed 2026-11-17)
- NIST Chemistry WebBook: carbon dioxide (accessed 2026-11-17)
- University of Pennsylvania EHRS SOP: Cryogens and Dry Ice (accessed 2026-11-17)
- University of Nevada, Reno EHS Chemical Hygiene Plan chapter 8 (accessed 2026-11-17)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.