Skip to main content
v2026.11,986 entries · CC-BY 4.0
LAC HealthSponsored

Shop n95 n99 supplies

  • FDA registered
  • ISO 13485
  • BBB Accredited A+

Shop at LAC Health

Direct comparison

N95 vs N99: NIOSH Filter Classes Compared

N95 vs N99: both are NIOSH N-series respirators (95% vs 99% minimum filtration, no oil resistance). Compare fit testing, airflow limits and approval checks.

Written and maintained by CASRAI Editorial Board

Last updated

How do N95 and N99 compare side by side?

The table below compares N95 and N99 across 11 dimensions, from what n99 stands for and what the numbers mean to when to pick each.

Side-by-side comparison

DimensionN95N99
What N99 stands for and what the numbers meanN means not resistant to oil. 95 means the filter captures at least 95% of airborne particles. NIOSH describes the N-series as filtering at least 95%, 99% or 99.97% of airborne particles.N means not resistant to oil. 99 means the filter captures at least 99% of airborne particles. An N99 mask is a NIOSH N-series filtering facepiece respirator at the 99% level, one step above N95.
Minimum filter efficiencyAt least 95% of airborne particles.At least 99% of airborne particles.
Oil resistanceNot resistant to oil (N-series). The oil-resistant versions of the 95% level are named R95 (somewhat resistant) and P95 (strongly resistant).Not resistant to oil (N-series). The oil-resistant versions of the 99% level are named R99 (somewhat resistant) and P99 (strongly resistant).
Next level upN99 is the next N-series class. NIOSH shows the 99.97% level as 100, so the top N-series class is labelled N100.N100 is the next N-series class. NIOSH notes that a 99.97% filtration efficiency is shown as 100 on filtering facepiece respirators.
Airflow resistance limit in 42 CFR 84.172Measured at a continuous 85 litres per minute. The maximum allowable inhalation resistance for non-powered N, R and P respirators is 35 mm of water-column height.The same rule applies: non-powered N, R and P respirators share one 35 mm water-column inhalation limit, so the regulation does not set a different resistance ceiling for N99.
Fit testingNIOSH states that filtering facepiece respirators require fit testing. A user seal check is only applicable after successful fit testing and is not a substitute for it.The same NIOSH statement applies to every filtering facepiece respirator, including N99: fit testing is required and a user seal check is not a substitute.
OSHA fit-test timing (29 CFR 1910.134)Under paragraph (f)(2), a tight-fitting respirator wearer is fit tested before initial use, whenever a different facepiece (size, style, model or make) is used, and at least annually.The same timing rule applies. A change from an N95 model to an N99 model is a different respirator facepiece, so it triggers a new fit test.
Measured performance in a laboratory studyIn Eninger and colleagues (2008), with respirators sealed on manikins, the one N95 tested had filtration that approached that of the two N99 models over particle sizes of about 0.02 to 0.5 micrometres.In the same study, more than 3% of MS2 virions penetrated both N99 models at the most penetrating particle size at 85 litres per minute. The study covered only three respirator models, so it does not rate the whole class.
How to confirm it is a NIOSH-approved respiratorIt should state NIOSH and the protection level (for example N95) and carry a testing and certification approval number such as TC 84A-XXXX. The number can be checked on the NIOSH Certified Equipment List.The same marking and approval-number check applies: NIOSH, the protection level (N99) and a TC number that can be validated on the NIOSH Certified Equipment List.
Difference from a surgical maskFDA describes an N95 as designed to achieve a very close facial fit and very efficient filtration of airborne particles. A surgical mask is a loose-fitting, disposable device.An N99 is also a tight-fitting respirator regulated by NIOSH, not a loose-fitting surgical mask. The FDA page cited here discusses N95 respirators and does not mention N99.
When to pick eachPick N95 when the hazard assessment calls for a 95% filter and the wearer has passed a fit test in that model. Surgical N95 versions add spray- and splash-resistant material for healthcare personnel.Pick N99 when the hazard assessment names a 99% minimum filter and the wearer has passed a fit test in that N99 model. The class label does not replace the fit test.

Ask CASRAI · full access

Ask about N95 vs N99: NIOSH Filter Classes Compared

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Common questions

Common questions about N95 vs N99

What is the difference between N95 and N99?

+

Both are NIOSH N-series filtering facepiece respirators that are not resistant to oil. The difference is the minimum filter efficiency: at least 95% of airborne particles for N95 and at least 99% for N99. Both need fit testing, and the same 35 mm water-column inhalation resistance limit applies to non-powered N, R and P respirators in 42 CFR 84.172.

What does N99 stand for?

+

In NIOSH labelling, N means the filter is not resistant to oil and 99 means it filters at least 99% of airborne particles. R99 is somewhat resistant to oil and P99 is strongly resistant to oil at the same 99% level.

What is an N99 mask?

+

An N99 mask is a NIOSH-approved N-series filtering facepiece respirator rated for at least 99% filtration. It is a tight-fitting respirator, so it needs fit testing, and it should show NIOSH, N99 and a TC approval number that can be checked on the NIOSH Certified Equipment List.

Which is better, N99 or N95?

+

N99 has the higher minimum filter efficiency (99% against 95%). But NIOSH says fit testing is required for filtering facepiece respirators, and OSHA requires a fit test before initial use, when a different facepiece is used and at least annually. In one laboratory study with respirators sealed on manikins, the N95 tested approached the filtration of two N99 models. The better choice is the class the hazard assessment calls for, in a model the wearer has been fit tested in. This page is not medical advice.

Are N95 masks better than surgical masks?

+

They do different jobs. FDA describes an N95 respirator as designed for a very close facial fit and very efficient filtration of airborne particles, while a surgical mask is a loose-fitting, disposable device that does not filter or block very small particles in the air. Surgical N95 respirators combine respirator filtration with spray- and splash-resistant material for healthcare personnel.

Does a user seal check replace a fit test?

+

No. NIOSH says a user seal check is only applicable once you have been successfully fit tested with a respirator, and that it is not a substitute for fit testing.

Data: NIOSH non-powered particulate respirator classes: minimum filter efficiency, oil resistance and inhalation resistance limit

Compiles the nine NIOSH non-powered particulate filter classes (N, R and P series at 95, 99 and 99.97 percent, labelled 100) from the NIOSH filtering facepiece respirator page and the 42 CFR 84.172 airflow resistance limit that applies to all non-powered N, R and P respirators.

Period covered: 2026. Coverage: United States.

NIOSH non-powered particulate respirator classes: minimum filter efficiency, oil resistance and inhalation resistance limit
Filter classMinimum filter efficiency (% of airborne particles)Oil resistanceMaximum inhalation resistance, non-powered N, R, P (mm water-column height)
N9595Not resistant to oil35
R9595Somewhat resistant to oil35
P9595Strongly resistant to oil35
N9999Not resistant to oil35
R9999Somewhat resistant to oil35
P9999Strongly resistant to oil35
N10099.97Not resistant to oil35
R10099.97Somewhat resistant to oil35
P10099.97Strongly resistant to oil35

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo