Shop medical supplies
- FDA registered
- ISO 13485
- BBB Accredited A+
Shop at LAC Health
Direct comparison
Tiger Top vs Gold Top Tube: SST Compared
Tiger top vs gold top tube: both are SSTs with the same clot activator and gel on BD's catalog; the closure and catalog number differ. Compare sizes and spin.
Written and maintained by CASRAI Editorial Board
Last updated
How do Tiger top (red/gray SST) and Gold top (Hemogard SST) compare side by side?
The table below compares Tiger top (red/gray SST) and Gold top (Hemogard SST) across 10 dimensions, from what the name refers to to when to pick each.
Side-by-side comparison
| Dimension | Tiger top (red/gray SST) | Gold top (Hemogard SST) |
|---|---|---|
| What the name refers to | Laboratory shorthand for the mottled red and gray closure. BD lists this closure colour as "Red/gray" (catalog 367981). | The gold closure. BD lists it as "Gold" with a BD Hemogard Closure (catalog 367983). |
| Closure on the BD catalog entry | Red/gray, Conventional (367981). | Gold, BD Hemogard Closure (367983). |
| Additive and gel | Clot activator and polymer gel (367981). | Clot activator and polymer gel (367983). |
| Size and draw volume, 13 x 75 mm entries | 13 x 75 mm, 3.5 mL draw (367981). | 13 x 75 mm, 3.5 mL draw (367983). |
| Larger format on the BD catalog | 16 x 100 mm, 7.5 mL draw, red/gray Conventional closure (367987). | Not part of this comparison: the larger entry read for this page (367987) is red/gray. |
| Tube material | Plastic (367981, 367987). | Plastic (367983). |
| Spin specification | BD states SST and PST gel tubes are spun at room temperature at 1000 to 1300 RCF for 10 minutes. | Same BD statement for SST gel tubes; it is made for the SST family, not for one closure colour. |
| Regulatory device type | Blood specimen collection device, 21 CFR 862.1675, Class II. | Blood specimen collection device, 21 CFR 862.1675, Class II. |
| Order-of-draw group | CASRAI's tube-color guide lists the serum group as red, red-speckled and gold. | Same serum group as the tiger top in that guide. |
| When to pick each | Use it when the laboratory's test directory or collection manual names the red/gray (tiger top) SST for the test. | Use it when the laboratory's test directory or collection manual names the gold SST for the test. The laboratory's own instructions decide, not the closure colour. |
Sources
- BD catalog pages 367981 and 367987, read 2026-10-30
- 21 CFR 862.1675, read 2026-10-30
- BD catalog page 367983, read 2026-10-30
Ask CASRAI · free to try
Ask about Tiger Top vs Gold Top Tube: SST Compared
2 free questions a day, no account.
An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.
Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.
Works on this site and inside Claude, Cursor and the AI tools you already use.
Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.
Common questions
Common questions about Tiger top (red/gray SST) vs Gold top (Hemogard SST)
Are tiger top and gold top tubes the same?
+
They are the same tube family. BD lists a red/gray Conventional-closure SST (367981) and a gold Hemogard-closure SST (367983) with the same clot activator and polymer gel and the same 13 x 75 mm, 3.5 mL size. The visible difference is the closure.
What is a tiger top tube?
+
Tiger top is laboratory shorthand for the mottled red and gray closure. On BD's catalog the matching SST entries are listed as red/gray (for example 367981 and 367987).
What additive is in a gold top tube?
+
BD lists the gold SST (367983) with a clot activator and polymer gel. For the red top additive question, see CASRAI's red top tube additive guide.
How are SST tubes centrifuged?
+
BD states that SST and PST gel tubes should be spun at room temperature at 1000 to 1300 RCF for 10 minutes. Follow the laboratory's own procedure for the test.
Which one should be used?
+
The laboratory performing the test decides. Its test directory or collection manual names the tube for each test.
Going deeper







