Mint Green Top Tube: Light Green PST Tube Explained

A mint green top tube is the light green lithium heparin gel (PST-type) tube. See how it differs from plain green tubes and its stated test exclusions.

Written and maintained by CASRAI Editorial Board

Published · Last updated

This page describes products and general use; it is not medical advice.

On this page

A mint green top tube is the pale green closure that most manufacturers call “light green”: a lithium heparin plasma tube with a gel barrier, sold by BD as the Vacutainer PST. It is not the same product as a plain green heparin tube. “Mint green” is the colloquial name; BD describes the closure as light green and Greiner as green, so match the additive and gel on the label, not the shade. Who uses it: clinic and laboratory staff who collect and process plasma samples, and buyers who must match a tube to a laboratory’s test requirements.

What a mint green top tube is

It is a vacuum blood-collection tube whose wall is coated with lithium heparin and which contains a barrier gel. BD lists its light-green Hemogard closure tube as “Lithium heparin 84 USP units with polymer gel” (BD Vacutainer PST product page). Greiner Bio-One’s VACUETTE Instructions for Use (980200B Rev09, 02-2020) lists the equivalent “Lithium Heparin w/Gel” tube with a green cap and a yellow inner ring.

Mint green vs dark green vs green with a yellow ring

Heparin tubes in the Greiner instructions for use all carry a green cap; the inner ring colour is what separates them. The BD PST tube is distinguished by its light-green closure. Always confirm the additive printed on the label.

Tube (manufacturer’s term) Closure / cap Additive and gel Source
BD Vacutainer PST BD Hemogard closure, light green Lithium heparin 84 USP units with polymer gel BD product page
VACUETTE Lithium Heparin w/Gel Green cap, yellow inner ring Lithium heparin with barrier gel Greiner instructions for use 980200B Rev09
VACUETTE Lithium Heparin Green cap, black or white inner ring Lithium heparin, no gel Greiner instructions for use 980200B Rev09
VACUETTE Sodium Heparin Green cap, green inner ring Sodium heparin, no gel Greiner instructions for use 980200B Rev09

Details of the plain green sodium and lithium heparin tubes are covered in what a green top tube is, and PST sizes and codes in PST tube colour and heparin gel tube sizes.

What the additive and gel do

Per the Greiner instructions for use, heparin activates antithrombins that block the coagulation cascade, so the tube yields whole blood and plasma rather than clotted blood and serum. In gel tubes, the gel’s specific gravity lies between the blood cells and the plasma; during centrifugation the barrier moves upward and forms a stable barrier between plasma and cells, so plasma can be aspirated directly from the collection tube.

Specifications to read on the label

Specification listed by BD for its light-green tube:

Item BD Vacutainer PST (light green)
Closure BD Hemogard, light green
Additive Lithium heparin, 84 USP units, with polymer gel
Tube size 13×100
Draw volume (as listed) 4.5 (unit not stated on the page)

Source: BD product page. Other tube sizes and heparin amounts exist; take them from the product page or packaging of the exact catalogue item.

Tests it should not be used for

The Greiner instructions for use states that its lithium heparin and lithium heparin with gel plasma tubes must not be used for lithium determinations or blood banking procedures, and that sodium heparin tubes must not be used for sodium determinations or blood banking procedures. It also states that venous blood collected in heparinized vacuum tubes is not suitable for blood gas analysis. For blood gas sampling devices see heparinized syringes.

Order of draw

Where a heparin tube sits in the collection sequence is set by each facility’s own protocol; the blood draw tube colours and order of draw chart lists the published sequence.

How to compare or substitute tubes

These checks follow directly from the manufacturer statements above. They are not a substitute for the laboratory’s own validation.

  • Match the additive: lithium versus sodium heparin, and gel versus no gel. Closure colour alone does not tell you, as the green-capped rows in the table show.
  • Read the amount of heparin and the tube size and draw volume for the exact catalogue item; BD lists 84 USP units for its 13×100 light-green tube.
  • Check the tube’s stated test exclusions (lithium determinations, blood banking, blood gas).
  • Read the manufacturer’s instructions for use supplied with the exact tube.

For a wider supply list see the phlebotomy lab supply checklist.

Common mistakes

  • Treating any green-capped tube as interchangeable: lithium and sodium heparin tubes have different stated test exclusions.
  • Choosing a lithium heparin tube for a lithium determination, which the Greiner instructions for use prohibit.
  • Assuming the shade of green identifies the product instead of the printed additive and gel.

FAQ

What is a mint green top tube?

It is the colloquial name for the light-green closure lithium heparin tube with gel (BD Vacutainer PST type), used to collect blood for plasma testing.

Is a mint green top tube the same as a green top tube?

No. Plain green heparin tubes contain lithium or sodium heparin without gel; the light-green PST type contains lithium heparin with a gel barrier. Compare the label additive.

Does the tube contain gel?

BD lists “lithium heparin 84 USP units with polymer gel” for its light-green tube.

Which tests should it not be used for?

Greiner’s instructions state that its lithium heparin tubes, with or without gel, are not for lithium determinations or blood banking, and that heparinized vacuum-tube blood is not suitable for blood gas analysis. Check the instructions for the exact tube.

Sources

Checked 2026-11-01.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Mint Green Top Tube: Light Green PST Tube Explained

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →