A Safety Data Sheet (SDS) for benzene outlines the hazardous properties, regulatory exposure thresholds, engineering controls, and emergency protocols required for working with this volatile aromatic hydrocarbon (CAS 71-43-2). Benzene is a Class IB flammable liquid with a closed-cup flash point of -11 °C (12 °F) and a confirmed human carcinogen (IARC Group 1) linked to acute myeloid leukemia and hematological damage. In laboratory settings, OSHA standard 29 CFR 1910.1028 mandates an 8-hour permissible exposure limit (PEL) of 1 ppm, a short-term exposure limit (STEL) of 5 ppm, and an action level of 0.5 ppm that triggers periodic monitoring and medical surveillance. Handling benzene requires certified chemical fume hoods, non-sparking transfer tools, specialized glove barriers such as Viton or Silver Shield rather than standard disposable nitrile, and hazardous waste disposal under RCRA codes U019, F005, or D018.

Benzene SDS Overview and Chemical Identification

Section 1 and Section 2 of a standardized 16-section Globally Harmonized System (GHS) Safety Data Sheet establish the chemical identity, supplier details, and hazard classifications for benzene. Benzene (molecular formula C6H6, CAS Number 71-43-2, EC Number 200-753-7) is a colorless, highly refractive liquid characterized by a distinct sweet, aromatic odor. Often cataloged under synonyms including benzol, phenyl hydride, and cyclohexatriene, technical and analytical grades typically exceed 99.0% chemical purity.

Under GHS criteria adopted by OSHA Hazard Communication Standard (29 CFR 1910.1200), benzene carries the signal word Danger alongside three primary hazard pictograms: the Flame (GHS02), the Exclamation Mark (GHS07), and the Health Hazard (GHS08). The core hazard classifications specified in manufacturer SDS documentation include:

  • Flammable Liquids (Category 2, H225): Highly flammable liquid and vapor.
  • Aspiration Hazard (Category 1, H304): May be fatal if swallowed and enters airways.
  • Skin Corrosion/Irritation (Category 2, H315): Causes skin irritation.
  • Serious Eye Damage/Eye Irritation (Category 2A, H319): Causes serious eye irritation.
  • Germ Cell Mutagenicity (Category 1B, H340): May cause genetic defects.
  • Carcinogenicity (Category 1A, H350): May cause cancer.
  • Specific Target Organ Toxicity — Repeated Exposure (Category 1, H372): Causes damage to organs (hematopoietic blood-forming system and bone marrow) through prolonged or repeated exposure.
  • Hazardous to the Aquatic Environment, Chronic (Category 3, H412): Harmful to aquatic life with long-lasting effects.

The accompanying precautionary statements govern laboratory practices. Prevention codes instruct personnel to obtain special instructions prior to handling (P201), keep containers isolated from heat, hot surfaces, sparks, and open flames (P210), ground and bond all transport vessels (P240), use explosion-proof electrical equipment (P241), and wear appropriate chemical-resistant protective gear (P280). Response statements emphasize that if swallowed, personnel must immediately call a poison control center or physician and refrain from inducing vomiting (P301 + P310 + P331).

Benzene Hazards: Toxicological Mechanisms and Health Effects

The health hazards associated with benzene represent one of the most thoroughly documented occupational risks in chemical toxicology. Exposure occurs primarily via inhalation of volatile vapors and secondary dermal absorption through direct liquid contact. Because benzene is lipophilic, it crosses cellular membranes rapidly, entering the systemic bloodstream where it is metabolized predominantly by hepatic cytochrome P450 enzymes (specifically CYP2E1) into benzene oxide, phenol, hydroquinone, catechol, and 1,4-benzoquinone. These reactive electrophilic metabolites migrate to bone marrow progenitor cells, generating oxidative stress, chromosomal translocations, mitotic spindle disruption, and DNA adducts.

Chronic occupational exposure suppresses bone marrow proliferation, resulting in progressive hematotoxicity that manifests clinically as pancytopenia, aplastic anemia, myelodysplastic syndromes (MDS), and acute myeloid leukemia (AML). Both the International Agency for Research on Cancer (IARC) and the US National Toxicology Program (NTP) designate benzene as a Group 1 known human carcinogen, as reviewed in the CASRAI IARC list of carcinogens classification guide. Laboratory workers face heightened risks during repetitive benchtop extractions, rotary evaporation without cold traps, or open-bench solvent transfers where localized vapor concentrations exceed background limits.

Acute exposure hazards induce central nervous system depression. Inhalation of vapor concentrations above 250 ppm produces acute symptoms including lightheadedness, headache, dizziness, nausea, confusion, and drowsiness. Exposure exceeding 1,000 ppm causes acute narcosis, cardiac arrhythmia, and loss of consciousness, while concentrations above 500 ppm reach the Immediately Dangerous to Life or Health (IDLH) ceiling established by the National Institute for Occupational Safety and Health (NIOSH). Furthermore, liquid benzene strips cutaneous lipid layers, producing erythema, drying, and chemical dermatitis upon dermal contact, while ocular contact elicits moderate to severe corneal conjunctival irritation.

Occupational Exposure Limits: OSHA Standard, Action Level, and Surveillance

Occupational exposure limits for benzene are subject to rigorous regulatory oversight. In the United States, general industry laboratories must comply with OSHA standard 29 CFR 1910.1028, which establishes both statutory concentration limits and administrative compliance triggers. Unlike generic substances governed solely by permissible exposure tables, benzene enforces an action level that obligates employers to institute surveillance and environmental monitoring before exposure reaches the statutory ceiling.

The regulatory limits and advisory benchmarks established across occupational health agencies include:

Governing Agency Exposure Metric Concentration Compliance Nature Target Organ / Regulatory Basis
OSHA (29 CFR 1910.1028) 8-hour TWA PEL 1.0 ppm (3.19 mg/m³) Mandatory Statutory Hematopoietic toxicity, leukemia risk reduction
OSHA (29 CFR 1910.1028) Short-Term Exposure Limit (STEL) 5.0 ppm (15.95 mg/m³) Mandatory Statutory (15 min) Acute central nervous system and respiratory protection
OSHA (29 CFR 1910.1028) Action Level 0.5 ppm (1.60 mg/m³) Mandatory Surveillance Trigger Initiates 6-month exposure monitoring & medical program
NIOSH Recommended Exposure Limit (REL) 0.1 ppm (0.32 mg/m³) Advisory Ceiling / 10-hr TWA Potential occupational carcinogen (minimize to lowest feasible level)
NIOSH STEL / Ceiling 1.0 ppm (3.19 mg/m³) Advisory 15-minute Ceiling Prevention of peak systemic inhalation
ACGIH Threshold Limit Value (TLV-TWA) 0.5 ppm Advisory Scientific Standard A1 Confirmed Human Carcinogen; Skin absorption notation
ACGIH TLV-STEL 2.5 ppm Advisory Scientific Standard Short-term transient peak control
NIOSH IDLH 500 ppm [Ca] Immediate Life/Health Threat Severe narcosis and acute fatal intoxication threshold

Understanding how statutory limits interact with advisory values is a cornerstone of lab hygiene, as detailed in our analysis of permissible exposure limits vs TLVs and RELs in laboratory environments. Under 29 CFR 1910.1028(i), any laboratory employee exposed to airborne benzene concentrations at or above the 0.5 ppm Action Level for 30 or more days per year, or at or above the 1.0 ppm PEL for 10 or more days per year, must be enrolled in an employer-provided medical surveillance program supervised by a licensed physician. The examination requires baseline and annual medical workups, complete blood count (CBC) testing with differential leukocyte counts, hematocrit, hemoglobin, red cell indices, and platelet quantification to detect occult marrow suppression.

In addition to atmospheric monitoring, biological monitoring evaluates systemic dose. The American Conference of Governmental Industrial Hygienists (ACGIH) establishes Biological Exposure Indices (BEIs) based on urinary excretion of metabolites collected at the end of an operational work shift: S-Phenylmercapturic acid (s-PMA) with a threshold of 25 μg/g creatinine, and trans,trans-muconic acid (t,t-MA) with a threshold of 500 μg/g creatinine. These biomonitoring parameters identify unrecognized dermal permeation or vapor breakthrough where personal air samplers underestimate total physiological uptake.

Benzene Flash Point, Combustible Vapors, and Fire Safety

Section 5 and Section 9 of the benzene SDS identify severe physical flammability hazards that demand strict engineering controls. Benzene has a closed-cup flash point of -11 °C (12.2 °F), an autoignition temperature of 498 °C (928 °F), and an explosive flammability range between 1.2% by volume (lower explosive limit, LEL) and 7.8% by volume (upper explosive limit, UEL). Because its flash point sits substantially below standard laboratory room temperature (20 °C to 25 °C), liquid benzene continuously generates combustible vapors capable of forming explosive fuel-air mixtures inside open vessels, sinks, or unventilated enclosures.

Benzene vapor density is 2.77 times heavier than air (air = 1.0). Consequently, escaping vapors do not rise toward ambient ceiling exhausts; instead, they sink, accumulate along bench surfaces, migrate across floors, and pool inside low-lying drainage gullies or electrical chases. If a vapor trail encounters a distant ignition source, such as a hot plate, electrical relay, or open flame, flashback along the vapor path to the solvent container can occur instantaneously. All heating of benzene reactions must utilize intrinsically safe heating mantles, oil baths, or hot plates certified for Class I, Division 1 or Division 2 hazardous locations; open burners and unshielded coil heaters are strictly prohibited.

When fighting a benzene fire, emergency responders must employ appropriate extinguishing media. Standard agents include alcohol-resistant foam, dry chemical powder, and carbon dioxide (CO2). Water streams must never be directed straight into burning pools of benzene: because benzene has a specific gravity of 0.88 g/cm3, it floats upon water, and high-pressure hose streams will scatter burning solvent across adjacent workstations. Water fog or fine spray may only be applied to cool surrounding, unopened drums and storage vessels to prevent catastrophic boiling liquid expanding vapor explosions (BLEVE).

Personal Protective Equipment: Glove Permeation and Respiratory Selection

Section 8 of the SDS mandates specific personal protective equipment (PPE) calibrated to the chemical properties of benzene. A widespread and dangerous compliance error in chemical laboratories is the routine use of standard disposable nitrile gloves when manipulating liquid benzene. Nitrile polymers provide high barrier efficiency against aliphatic hydrocarbons, but aromatic hydrocarbons rapidly permeate and degrade nitrile elastomers. Under ASTM F739 continuous permeation testing, standard 4-mil to 5-mil disposable nitrile gloves exhibit benzene breakthrough in less than 2 to 5 minutes, accompanied by matrix swelling and complete loss of barrier integrity.

Laboratory personnel must select glove materials verified by ASTM F739 permeation standards:

  • Silver Shield / 4H (Polyethylene/Ethylene Vinyl Alcohol Laminate): Offers the highest chemical resistance profile, with measured benzene breakthrough times exceeding 480 minutes (8 hours). While Silver Shield liners lack mechanical elasticity, wearing them as an under-glove beneath an outer disposable glove provides superior chemical protection combined with physical grip.
  • Viton (Fluoroelastomer): Provides excellent chemical barrier protection, with breakthrough times exceeding 480 minutes along with superior flexibility and tactile dexterity compared to laminate materials. Viton gloves represent the preferred choice for direct solvent manipulation, synthetic chemistry, and liquid decanting.
  • Polyvinyl Alcohol (PVA): Demonstrates excellent resistance to aromatic hydrocarbons with breakthrough times exceeding 480 minutes. However, PVA is water-soluble; any moisture, perspiration, or aqueous solvent mixture causes rapid dissolution and structural failure of the glove material.
  • Prohibited Materials: Thin nitrile, neoprene, natural rubber (latex), and polyvinyl chloride (PVC) must never be used for intentional contact or handling of benzene liquids due to rapid chemical breakthrough and catastrophic solvent permeation.

The data table below summarizes ASTM F739 chemical glove permeation breakthrough times for benzene across polymer materials, providing a direct comparison of barrier duration and laboratory operational verdicts.

Respiratory protection follows a strict hierarchy of controls. All open manipulation of benzene must occur within a certified chemical fume hood maintaining an average face velocity of 80 to 120 feet per minute (fpm). If airborne monitoring indicates concentrations approaching or exceeding the 0.5 ppm Action Level or if emergency spill mitigation is underway, personnel must utilize NIOSH-approved full-facepiece air-purifying respirators equipped with organic vapor cartridges. Because organic vapor cartridges lack an active end-of-service-life indicator (ESLI) for benzene, OSHA 29 CFR 1910.1028 mandates a documented cartridge change schedule based on temperature, humidity, and expected vapor loading. For concentrations exceeding 10 ppm or entering IDLH atmospheres (500 ppm), positive-pressure supplied-air respirators or self-contained breathing apparatus (SCBA) are legally required.

Benzene Storage: Flammable Cabinets, Incompatibilities, and Static Grounding

Storage guidelines outlined in Section 7 and Section 10 of the SDS classify benzene as an NFPA 30 Class IB flammable liquid (flash point below 22.8 °C / 73 °F and boiling point at or above 37.8 °C / 100 °F). Quantities exceeding standard operational benchtop aliquots must be stored within heavy-gauge, double-walled steel flammable storage cabinets meeting NFPA 30 and OSHA 1910.106 construction specifications. Cabinets should be located away from laboratory exits, direct sunlight, and heat sources, with ventilation bungs sealed unless connected to an approved, dedicated external exhaust duct.

Chemical compatibility is a critical determinant of storage safety. Benzene reacts violently with strong oxidizing agents, introducing severe risks of spontaneous combustion and explosion. The SDS highlights severe chemical incompatibilities that must be segregated in secondary containment:

  • Concentrated Mineral Acids: Contact with concentrated nitric acid (HNO3) or mixed nitrating acids produces uncontrolled, highly exothermic electrophilic nitration reactions that can trigger thermal runaway and detonation.
  • Halogens and Interhalogens: Mixtures of benzene with chlorine, bromine, or fluorine in the presence of Lewis acid catalysts (such as ferric chloride or aluminum chloride) react violently with rapid release of toxic hydrogen halide gases.
  • Perchlorates, Permanganates, and Peroxides: Strong oxidizing salts form contact-sensitive explosive mixtures when combined with organic aromatics.
  • Ozone and Liquid Oxygen: Contact with liquid oxygen or strong ozonolysis streams generates unstable, shock-sensitive ozonides.

Container selection must account for solvent compatibility. Glass reagent bottles with PTFE-lined caps represent the standard analytical container. When selecting polymer labware, personnel should consult a verified chemical resistance chart for plastics in laboratory container selection to prevent container failure: high-density polyethylene (HDPE) and polypropylene (PP) exhibit stress cracking and solvent permeation over extended contact, whereas fluoropolymers (PTFE, PFA, FEP) provide complete chemical inertness.

Static electricity mitigation is mandatory during bulk transfer. Because benzene is a low-conductivity organic liquid (dielectric constant 2.28), electrical charges accumulate during pouring, pumping, or agitation. Dispensing from metal drums or safety cans requires mechanical bonding and grounding cables to equalize electrical potential between vessels and earth ground, preventing electrostatic spark discharge below the -11 °C flash point threshold.

Benzene Disposal: RCRA Waste Codes and Laboratory Protocols

Disposal of laboratory benzene waste is strictly regulated under the Resource Conservation and Recovery Act (RCRA, 40 CFR Parts 260–268). Chemical hygiene officers and laboratory staff must accurately assign federal hazardous waste codes based on chemical origin, matrix state, and solvent concentration before staging waste for collection.

Laboratory benzene waste streams typically fall under three distinct RCRA regulatory classifications:

  1. U019 (Commercial Chemical Products): Applies to unused commercial formulations, off-specification reagents, expired stock bottles, or residue remaining from cleanups of unused commercial benzene (40 CFR § 261.33). If an unopened or pure reagent bottle of benzene is discarded, it must be designated and manifested as U019 toxic waste.
  2. F005 (Spent Non-Halogenated Solvents): Governs spent solvent mixtures derived from extraction, degreasing, chromatography, or synthetic wash operations where the solvent formulation contained 10% or more benzene by volume before use (40 CFR § 261.31). Routine laboratory solvent carboys containing spent benzene washings carry the F005 listing along with other co-solvents like toluene or acetone, as detailed in our guide to RCRA hazardous waste codes and F, K, P, and U determinations.
  3. D018 (Toxicity Characteristic): Pertains to solid wastes, contaminated soil, aqueous rinsates, or laboratory debris that release benzene at or above the regulatory threshold of 0.5 mg/L (500 ppb) when evaluated by the Toxicity Characteristic Leaching Procedure (TCLP, EPA Method 1311; 40 CFR § 261.24). Waste failing the TCLP threshold exhibits the toxicity characteristic and must be managed as D018 hazardous waste.

Under no circumstances may benzene waste or aqueous extracts be poured into sanitary sewer sinks or allowed to evaporate inside a fume hood. Liquid benzene waste must be collected in compatible, vapor-tight, dedicated waste containers (such as safety cans or fluoropolymer carboys) labeled with the words ‘Hazardous Waste’, the specific chemical constituents, and the applicable EPA waste codes. Contaminated solid labware, including pipette tips, disposable transfer pipettes, wiping tissues, and personal protective equipment, must be segregated into sealed, heavy-gauge polyethylene waste bags and designated as hazardous solid waste subject to licensed high-temperature incineration.

Common Laboratory Misunderstandings and Compliance Pitfalls

Evaluating safety data sheets across academic and industrial laboratories reveals recurring compliance pitfalls regarding benzene safety. Correcting these misunderstandings is essential for maintaining an audit-ready chemical hygiene plan:

1. Relying on Odor Threshold for Warning: Benzene possesses a detectable aromatic odor, but human olfactory thresholds range between 1.5 ppm and 5.0 ppm. Because the odor threshold significantly exceeds both the 0.5 ppm Action Level and the 1.0 ppm OSHA PEL, odor provides zero reliable warning of hazardous vapor concentrations. Personnel who smell benzene are already experiencing airborne exposures exceeding federal statutory limits.

2. Assuming Toluene or Xylene Are Direct Drop-In Replacements Without Protocol Adjustments: While toluene and xylene frequently serve as less toxic chemical substitutes for benzene, they possess different boiling points, vapor pressures, and metabolic pathways, as compared in the CASRAI toluene SDS hazards, storage, and disposal guide. Substituting solvents requires re-optimizing reflux temperatures, rotary evaporator vacuum depths, and extraction kinetics rather than assuming identical physical behavior.

3. Using Disposable Nitrile Gloves for Splash Protection Without Immediate Changing: Many researchers believe that disposable nitrile gloves offer sufficient protection for short, accidental splashes. In reality, liquid benzene permeates 4-mil nitrile within seconds, trapping volatile solvent against the warm skin of the hand, where cutaneous absorption accelerates. Any glove exposed to a benzene droplet must be stripped immediately, hands washed with non-abrasive soap and copious water, and a fresh glove donned.

4. Treating Fume Hood Evaporation as a Waste Treatment Method: Allowing open beakers of spent benzene to evaporate inside a chemical fume hood violates EPA RCRA regulations prohibiting unpermitted atmospheric disposal of hazardous waste. All solvent volumes must be captured in closed containment vessels.

Frequently asked questions

What is the OSHA Permissible Exposure Limit (PEL) for benzene in laboratories?

Under OSHA standard 29 CFR 1910.1028, the statutory Permissible Exposure Limit (PEL) for benzene is 1.0 ppm (parts per million) as an 8-hour time-weighted average (TWA). OSHA also enforces a Short-Term Exposure Limit (STEL) of 5.0 ppm over a 15-minute sampling period, and an Action Level of 0.5 ppm as an 8-hour TWA. Exposure at or above the 0.5 ppm Action Level triggers mandatory environmental monitoring every six months and enrollment in an employer-provided medical surveillance program.

Why are standard disposable nitrile gloves unsafe for handling benzene?

Standard 4-mil to 5-mil disposable nitrile gloves provide virtually no barrier protection against liquid benzene. Under standard ASTM F739 continuous permeation testing, benzene permeates nitrile polymers in less than 2 to 5 minutes, causing swelling, loss of elasticity, and rapid breakthrough to the skin. Laboratory personnel handling benzene must wear fluoropolymer gloves such as Viton or multi-layer laminate barriers such as Silver Shield / 4H, which provide breakthrough times exceeding 480 minutes (8 hours).

What is the closed cup flash point of benzene and what storage class applies?

Benzene has a closed-cup flash point of -11 °C (12.2 °F), an autoignition temperature of 498 °C (928 °F), and an explosive flammability range between 1.2% (LEL) and 7.8% (UEL) in air. Under NFPA 30 standards, benzene is classified as a Class IB flammable liquid (flash point below 22.8 °C and boiling point at or above 37.8 °C). Quantities exceeding bench aliquots must be stored within heavy-gauge double-walled steel flammable storage cabinets with grounding and bonding protocols applied during liquid dispensing.

When is medical surveillance mandatory under OSHA 29 CFR 1910.1028?

Medical surveillance is legally required for any laboratory employee who is exposed to airborne benzene concentrations at or above the 0.5 ppm Action Level for 30 or more days per year, or at or above the 1.0 ppm PEL for 10 or more days per year. The program must be supervised by a licensed physician at no cost to the employee, incorporating initial baseline and annual medical examinations, occupational history, and complete blood count (CBC) testing with differential leukocyte and platelet counts to monitor bone marrow function.

How should spent benzene waste and contaminated debris be classified under RCRA?

Under EPA RCRA regulations, pure unused discarded benzene is designated as U019 toxic hazardous waste (40 CFR § 261.33). Spent solvent mixtures containing 10% or more benzene before use are listed as F005 hazardous waste (40 CFR § 261.31). Contaminated labware, soils, or aqueous solutions releasing benzene at or above 0.5 mg/L via the Toxicity Characteristic Leaching Procedure (TCLP) are regulated under characteristic code D018 (40 CFR § 261.24). Benzene waste must never be discharged to municipal drains or evaporated inside fume hoods.

Sources

  • Occupational Safety and Health Administration (OSHA). 29 CFR 1910.1028 — Benzene Standard. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1028 (accessed 2026-11-14).
  • National Institute for Occupational Safety and Health (NIOSH). NIOSH Pocket Guide to Chemical Hazards: Benzene (CAS 71-43-2). https://www.cdc.gov/niosh/npg/npgd0049.html (accessed 2026-11-14).
  • MilliporeSigma. Safety Data Sheet: Benzene (Product Number 270709, CAS 71-43-2). https://www.sigmaaldrich.com (accessed 2026-11-14).
  • Fisher Scientific. Safety Data Sheet: Benzene, ACS Reagent Grade (Catalog B245 / B414). https://www.fishersci.com (accessed 2026-11-14).
  • American Conference of Governmental Industrial Hygienists (ACGIH). Threshold Limit Values (TLVs) and Biological Exposure Indices (BEIs): Benzene. https://www.acgih.org (accessed 2026-11-14).
  • United States Environmental Protection Agency (EPA). 40 CFR Part 261 — Identification and Listing of Hazardous Waste (Codes U019, F005, D018). https://www.epa.gov (accessed 2026-11-14).
  • ASTM International. ASTM F739 — Standard Test Method for Permeation of Liquids and Gases through Protective Clothing Materials under Conditions of Continuous Contact. https://www.astm.org/f0739-20.html (accessed 2026-11-14).

Data: Chemical Glove Permeation and Breakthrough Times for Benzene

Standardized continuous permeation resistance, breakthrough duration, and laboratory suitability ratings for common protective glove materials exposed to liquid benzene, compiled from ASTM F739 permeation tests and manufacturer EHS resistance data.

Period covered: 2024/2026. Coverage: United States.

Chemical Glove Permeation and Breakthrough Times for Benzene
Glove MaterialASTM F739 Breakthrough Time (min)Degradation RatingLab Suitability Verdict
Silver Shield / 4H (PE/EVOH Laminate)480ExcellentRecommended (universal chemical barrier; ideal inner liner beneath work gloves)
Viton (Fluoroelastomer)480Good to ExcellentRecommended (high dexterity and vapor resistance; avoid mechanical puncture)
Polyvinyl Alcohol (PVA)480Good (Anhydrous)Conditional (strictly anhydrous only; water-soluble and degrades in sweat)
Neoprene (Polychloroprene)20Poor to FairNot Recommended (rapid swelling and breakthrough under continuous contact)
Nitrile (Disposable 4-5 mil)5PoorNot Recommended (dangerously rapid permeation; incidental micro-splash only)
Natural Rubber (Latex)5PoorProhibited (immediate degradation and swelling; zero barrier protection)

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Benzene SDS: Laboratory Hazards, Exposure Limits, and Safety Protocols

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →