Skip to main content
v2026.11,986 entries · CC-BY 4.0

Bridge Engineering: Design, Inspection and Standards

Bridge engineering in the U.S.: the 20-foot legal definition, AASHTO design editions in 23 CFR 625.4 and NBIS inspection intervals side by side.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Bridge engineering is the branch of civil engineering that plans, designs, builds, inspects and maintains bridges. In the United States, federal regulation gives it an unusually precise legal frame: a “bridge” is a structure with an opening of more than 20 feet measured along the roadway centerline, federal-aid highway bridges are designed to the AASHTO specifications that 23 CFR 625.4 incorporates, and every bridge on public roads is inspected on intervals set by 23 CFR 650.311, with the results recorded in the National Bridge Inventory.

Short answer

Bridge engineering covers three linked activities, and U.S. federal rules govern each through a different document. Design follows the AASHTO specifications listed in 23 CFR 625.4. Inspection follows the National Bridge Inspection Standards (NBIS) in 23 CFR Part 650, Subpart C. Record-keeping follows the National Bridge Inventory (NBI), which FHWA governs through the Specifications for the National Bridge Inventory (SNBI). This page cross-walks the three and compares the inspection intervals side by side.

Definition and scope

The NBIS definitions in 23 CFR 650.305 (read 2026-11-12) define a bridge as a structure, including supports, erected over a depression or an obstruction such as water, a highway or a railway, with a track or passageway for carrying traffic or other moving loads, and with an opening measured along the center of the roadway of more than 20 feet between the under copings of abutments, the spring lines of arches, or the extreme ends of openings for multiple boxes. The definition also covers multiple pipes where the stated clear-distance condition is met. A structure shorter than that opening is therefore not a “bridge” for NBIS purposes, however it is described locally.

Bridge engineering is a specialty inside the structural and transportation branches of civil engineering. Its work products include structure-type selection, structural analysis and design, construction specifications, load rating, inspection programmes and rehabilitation decisions. For how civil engineering as a whole sits among neighbouring disciplines, see civil engineering vs. environmental engineering.

How bridge engineering is used in practice

Selecting a structure type

The Steel Bridge Design Handbook, originally published by FHWA and now maintained by the National Steel Bridge Alliance and AISC, devotes Chapter 5 to “Selecting the Right Bridge Type”. It treats rolled steel beam, plate girder, truss, arch, cable-stayed and suspension options, and states that selecting the right structure type is probably the most important aspect of designing a cost-effective bridge. The handbook is a design reference for steel bridges specifically; it is not a statement of which type suits which span, and this page does not give span ranges.

Design standards: what 23 CFR 625.4 incorporates

23 CFR 625.4 (read 2026-11-12) lists the standards that apply to highway bridge design on federal-aid projects. Among the AASHTO documents it incorporates by reference are the LRFD Bridge Design Specifications, 8th Edition (2017), the LRFD Bridge Construction Specifications, 4th Edition (2017), the Standard Specifications for Highway Bridges, 17th Edition (2002), and the LRFD Movable Highway Bridge Design Specifications, 2nd Edition (2007) with interim revisions through 2018. The rule also references the AASHTO/AWS D1.5 Bridge Welding Code. The edition named in the regulation is the edition that is legally incorporated, which can differ from the newest edition AASHTO has published; check the current text of 625.4 and any FHWA notice before citing an edition in a project document.

Inspection: the NBIS

The NBIS sets how bridges are inspected, who may lead an inspection team and how often inspections occur. 23 CFR 650.305 defines the terms inspection records depend on:

  • Routine inspection: a regularly scheduled comprehensive inspection of observations and measurements needed to determine the physical and functional condition of the bridge and identify changes from previously recorded conditions.
  • In-depth inspection: a close-up, detailed inspection of one or more members above or below water, using visual or nondestructive evaluation techniques, to find deficiencies not readily detectable in a routine inspection.
  • Hands-on inspection: inspection within arm’s length of the member, using visual techniques that may be supplemented by nondestructive evaluation.
  • Special inspection: an inspection scheduled at the owner’s discretion to monitor a known or suspected deficiency or unusual details.
  • Damage inspection: an unscheduled inspection to assess structural damage from environmental factors or human actions.
  • Load rating: the analysis that determines the safe vehicular live load carrying capacity of a bridge, using plans supplemented by measurements and inspection information. Load posting refers to the regulatory signs showing the maximum vehicular live load the bridge may safely carry.
  • Critical finding: a structural or safety-related deficiency that requires immediate action to ensure public safety.
  • Scour critical bridge: a bridge with a foundation member that is unstable, or may become unstable, as determined by the scour appraisal.
  • Nonredundant steel tension member (NSTM): a primary steel member fully or partially in tension and without load path redundancy.

FHWA’s bridge inspection page (read 2026-11-12) points to the NBIS, an Inspection Interval Guidance memorandum dated 13 June 2022, the Bridge Inspector’s Reference Manual (2022 NBIS version) and National Highway Institute training.

Inventory: the NBI and SNBI

The FHWA National Bridge Inventory page (read 2026-11-12) states that the NBI is governed by the Specifications for the National Bridge Inventory (SNBI) and offers downloadable NBI data, the SNBI schema, a validation module and the Long-Term Bridge Performance InfoBridge web portal for querying and visualising data. The interval rules below refer to NBI items by name, for example the Scour Condition Rating and the Inventory Load Rating Factor, so the inspection regulation and the inventory are designed to be read together.

Inspection intervals compared

The intervals below are compiled from 23 CFR 650.311 (read 2026-11-12) and sets Method 1 (simplified risk) maximum intervals for three inspection types.

In prose: routine inspections run on a 24-month regular interval, shortened to 12 months and extendable to 48 months when the criteria are met. Underwater inspections run on a 60-month regular interval, shortened to 24 months and extendable to 72. Nonredundant steel tension member inspections run on a 24-month regular interval, shortened to 12 months and extendable to 48. The full set of intervals, including the Method 2 risk categories, is in the downloadable dataset on this page.

What triggers the reduced interval

  • Routine (12 months): any of the deck, superstructure, substructure or culvert components rated 3 or less (“serious or worse”), or a Scour Condition Rating of 3 or less, as recorded in the NBI. Owners must also document their own criteria for reducing intervals below 24 months, considering structure type, design, materials, age, condition ratings, scour, environment, traffic, vehicle-impact history, loads and safe load capacity, and other known deficiencies.
  • Underwater (24 months): underwater portions, channel or channel protection rated 3 or less, or a Scour Condition Rating of 3 or less.
  • NSTM (12 months): an NSTM Inspection Condition rating of 4 or less.

What is required before an interval is extended

Extended intervals are allowed only when every listed criterion is met and the owner has a documented extended-interval policy and has notified FHWA in writing before implementation. For routine inspection up to 48 months, the criteria include all main components rated 6 or greater, channel condition rated 6 or greater, an Inventory Load Rating Factor of at least 1.0 with unrestricted routine permit loads, no Category E or E’ fatigue details on a steel bridge, roadway vertical clearances of at least 14 feet 0 inches, a limited set of superstructure materials and types, and stable scour conditions. For NSTMs up to 48 months, the criteria include construction after 1978 under a fracture control plan, no fatigue details with finite life, no history of fatigue cracks, a rating of 6 or greater, and no pin and hanger assemblies. Underwater inspections can extend to 72 months only where the underwater portions, channel and scour condition are all rated 6 or greater and the bridge is stable for potential scour.

Method 2 and service inspections

Method 2 replaces the simplified categories with a more rigorous risk assessment developed by a Risk Assessment Panel of at least four people, at least two of them professional engineers, including the NBIS program manager. The policy goes to FHWA for approval. Bridges classified in poor condition cannot exceed a 24-month routine interval, and bridges in fair condition cannot exceed 48 months. When a risk-based routine interval exceeds 48 months, a service inspection must be performed midway between routine inspections. A new, rehabilitated or structurally modified bridge must receive an initial inspection, be in service for 24 months and receive its next routine inspection before it is eligible for intervals above 24 months.

Scour has no interval of its own in this section; it works through the routine and underwater rules above. Deterioration modes that a Method 2 assessment must consider include section loss, fatigue and fracture in steel members, flexural and shear cracking and reinforcement corrosion in concrete members, and settlement, rotation, overload, vehicle or vessel impact and scour in the structure as a whole.

Cross-walk: which document answers which question

Question Where the answer sits
Is this structure a “bridge”? 23 CFR 650.305 (opening of more than 20 feet along the roadway centerline)
Which design specifications apply on federal-aid projects? 23 CFR 625.4 (AASHTO LRFD Bridge Design Specifications, 8th Edition 2017, among others)
How often must it be inspected? 23 CFR 650.311 (Method 1 or approved Method 2)
Where are condition ratings recorded and queried? National Bridge Inventory under the SNBI; FHWA InfoBridge portal
What training and method guidance exists for inspectors? Bridge Inspector’s Reference Manual and National Highway Institute courses, via FHWA
How is a steel bridge type chosen? Steel Bridge Design Handbook, Chapter 5

Where it matters for researchers and research facilities

Editorial interpretation: because the NBI is public and downloadable with its schema and a validation module, bridge condition work can be reproduced from the same data owners report to FHWA, and a study that uses NBI fields should cite the SNBI schema version it downloaded. Research that touches inspection, such as nondestructive evaluation or structural health monitoring, sits next to the NBIS terms above: “hands-on” and “in-depth” have regulatory meanings, so a monitoring method is not automatically equivalent to either. For materials and testing questions that sit upstream of bridge work, see recycled asphalt pavement for the laboratory limits of one road-surface material, and SAP2000 for one widely used structural analysis package. Entering a bridge’s enclosed spaces is a separate safety topic covered under confined space entry rules.

Common misunderstandings

  • “A bridge is any structure that crosses something.” For NBIS, the 20-foot opening threshold applies; shorter structures fall outside the definition.
  • “Every bridge is inspected every two years.” 24 months is the regular maximum under Method 1, but reduced intervals of 12 months, and extended intervals of 48 or more months where criteria and approvals are met, also exist. Underwater and NSTM inspections run on their own schedules.
  • “The newest AASHTO edition is the legal one.” The regulation names specific incorporated editions; a newer edition may be optionally approved without replacing them.
  • “Load rating and load posting are the same thing.” Load rating is an analysis; load posting is the signage that reflects the maximum safe load.
  • “A scour rating sets its own inspection date.” Scour ratings influence the routine and underwater intervals but do not create a separate interval.

FAQ

Under 23 CFR 650.305, a bridge is a structure carrying traffic or other moving loads over a depression or obstruction such as water, a highway or a railway, with an opening of more than 20 feet measured along the roadway centerline.

How often must bridges be inspected?

Under Method 1 of 23 CFR 650.311, routine inspections may not exceed 24 months, drop to 12 months when listed condition or scour ratings are 3 or less, and can reach 48 months when every extended-interval criterion is met. Underwater and NSTM inspections have separate intervals shown in the table.

Which design specifications do federal-aid highway bridges follow?

23 CFR 625.4 incorporates the AASHTO LRFD Bridge Design Specifications, 8th Edition (2017), together with companion construction, movable-bridge and welding documents. Check the current regulation text for changes.

What is a nonredundant steel tension member?

It is a primary steel member that is fully or partially in tension and has no load path redundancy, so its failure is not backed up by another load path. NSTMs have their own inspection interval.

Where can I find bridge condition data?

FHWA’s National Bridge Inventory page provides downloadable NBI data, the SNBI schema, a validation module and the InfoBridge portal.

Sources

Data: NBIS maximum bridge inspection intervals by inspection type (Method 1 and Method 2), 23 CFR 650.311

Maximum inspection intervals in months for routine, underwater and nonredundant steel tension member inspections under the National Bridge Inspection Standards, compiled from the text of 23 CFR 650.311: Method 1 regular, reduced and extended intervals, the Method 2 risk-category intervals, and the reduced-interval trigger.

Period covered: 2026. Coverage: United States.

NBIS maximum bridge inspection intervals by inspection type (Method 1 and Method 2), 23 CFR 650.311
Inspection typeMethod 1 regular interval (months)Method 1 reduced interval (months)Method 1 extended interval (months)Method 2 risk-category intervals (months)Reduced-interval trigger (NBI rating)
Routine inspection24124812, 24, 48, 72Reduced: deck, superstructure, substructure or culvert condition rating 3 or less, or Scour Condition Rating 3 or less
Underwater inspection60247224, 60, 72Reduced: underwater, channel or channel protection condition 3 or less, or Scour Condition Rating 3 or less
Nonredundant steel tension member (NSTM) inspection24124812, 24, 48Reduced: NSTM Inspection Condition rating 4 or less

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Bridge Engineering: Design, Inspection and Standards

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →