Written and maintained by CASRAI Editorial Board
Published
On this page
A bromine safety data sheet (SDS) outlines the regulatory classifications, severe physiological hazards, strict occupational exposure limits, and specialized engineering controls required for handling elemental bromine (CAS 7726-95-6, UN 1744) in academic, clinical, and industrial laboratories. Bromine is an intensely corrosive, dense, fuming reddish-brown liquid classified under the Globally Harmonized System (GHS) as fatal if inhaled (Acute Toxicity Inhalation Category 1, H330), severely damaging to skin and eyes (Skin Corrosion Category 1A, H314; Serious Eye Damage Category 1, H318), and acutely toxic to aquatic ecosystems (Aquatic Acute Category 1, H400). Occupational exposure is tightly restricted by OSHA and NIOSH to an 8-hour permissible exposure limit of 0.1 ppm (0.7 mg/m³), requiring handling exclusively within certified chemical fume hoods, specialized Viton personal protective equipment, and dedicated spill neutralization protocols.
Definition and scope of bromine safety data sheets
The safety data sheet for elemental bromine serves as the foundational regulatory and operational safety document across research laboratories, chemical synthesis facilities, and environmental testing institutions. Structured in accordance with the 16-section standardized format established by the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) and codified under the OSHA Hazard Communication Standard (29 CFR 1910.1200), the document translates empirical toxicological, chemical, and physical property data into actionable laboratory safeguards.
Elemental bromine (molecular formula Br₂, molecular weight 159.81 g/mol) is one of only two elements in the periodic table that exists as a liquid under standard temperature and pressure conditions (0°C to 25°C and 1 atm). Due to its high vapor pressure (175 mmHg at 20°C) and substantial liquid density (3.102 g/cm³), the compound behaves fundamentally differently from common organic solvents or mineral acids. An SDS for bromine defines the specific parameters under which laboratory personnel can store, transport, manipulate, and neutralize this reagent without catastrophic chemical exposure or infrastructure degradation.
Within institutional safety programs, the bromine SDS directly informs chemical hygiene plans (CHPs), standard operating procedures (SOPs), designated work area allocations, and regulatory compliance under corrosive chemical handling and first aid protocols. Furthermore, because commercial bromine shipments are regulated as hazardous materials with severe toxicity by inhalation designations, SDS Section 14 provisions guide institutional receiving and internal shipping under DOT hazardous materials regulations under 49 CFR Part 172.
Bromine hazards: GHS classification and physiological effects
The hazard classification of elemental bromine is characterized by exceptional acute toxicity, aggressive tissue destruction, and profound environmental persistence. Under GHS criteria reflected across major manufacturer documentation, bromine is assigned the Signal Word DANGER and three mandatory pictograms: GHS05 (Corrosion), GHS06 (Skull and Crossbones), and GHS09 (Environment). Understanding these designations is essential for assessing operational risk at the laboratory bench.
The primary GHS hazard statements associated with pure elemental bromine include:
- H330: Fatal if inhaled (Category 1 / Category 2) — Inhalation of bromine vapors represents an immediate life-threatening hazard. Bromine vapor is intensely irritating to the entire respiratory tract, causing violent coughing, bronchial spasm, glottic edema, and chemical pneumonitis. Most critically, severe acute exposures can produce delayed non-cardiogenic pulmonary edema, which may manifest 24 to 48 hours after exposure without immediate warning symptoms.
- H314: Causes severe skin burns and eye damage (Category 1A) — Liquid bromine rapidly penetrates epithelial tissue, oxidizing organic macromolecules and generating hydrobromic acid within cellular water. This produces characteristic painful, deep, slow-healing burns that turn yellow-brown before ulcerating. Unlike superficial acid burns, bromine continues to penetrate dermal layers until thoroughly reduced and decontaminated.
- H318: Causes serious eye damage (Category 1) — Direct contact with liquid bromine or high concentrations of vapor causes immediate corneal opacification, severe conjunctival necrosis, and permanent loss of vision. Bromine is also a potent lachrymator at sub-lethal concentrations.
- H400: Very toxic to aquatic life (Acute Category 1) — Elemental bromine is exceptionally biocidal in aquatic environments, necessitating zero-discharge containment to prevent storm drain or municipal sewer contamination.
In comparison with other high-hazard laboratory reagents, such as those detailed in the phenol SDS and toxic exposure protocols or sodium azide laboratory safety guidelines, bromine presents an elevated volatility hazard combined with rapid dermal destruction. While systemic toxicity from absorption can lead to circulatory collapse, renal injury, and central nervous system depression, immediate localized tissue destruction and airway obstruction represent the primary lethal mechanisms in laboratory incidents.
Occupational exposure limits and airborne monitoring standards
Occupational exposure limits (OELs) established by federal regulatory agencies and occupational health organizations impose exceptionally stringent thresholds on permissible airborne concentrations of bromine in workplace air. Because bromine vapors cause immediate cellular damage upon contact with moist mucosal surfaces, regulatory authorities do not allow high time-weighted average exposures.
The authoritative occupational exposure limits for bromine (CAS 7726-95-6) include:
- OSHA Permissible Exposure Limit (PEL): 0.1 ppm (0.7 mg/m³) as an 8-hour time-weighted average (TWA), codified under 29 CFR 1910.1000 Table Z-1. OSHA enforces this ceiling to prevent cumulative respiratory impairment and chronic mucosal irritation among laboratory personnel.
- NIOSH Recommended Exposure Limit (REL): 0.1 ppm (0.7 mg/m³) TWA for up to a 10-hour workday during a 40-hour workweek, accompanied by a Short-Term Exposure Limit (STEL) of 0.3 ppm (2 mg/m³) over a 15-minute sampling period. The STEL ensures that transient exposure spikes during chemical transfers do not produce acute bronchial damage.
- NIOSH Immediately Dangerous to Life or Health (IDLH): 3 ppm. This critical benchmark represents the maximum airborne concentration from which a worker could escape within 30 minutes without irreversible health effects or escape-impairing symptoms. At 3 ppm, bromine vapor produces incapacitating glottic irritation and severe lacrimation that prevents unassisted egress.
- ACGIH Threshold Limit Value (TLV): 0.1 ppm 8-hour TWA, with an ACGIH STEL of 0.2 ppm, reflecting updated recommendations to minimize sub-clinical airway inflammation.
A critical safety limitation in laboratory practice is human odor perception. While the odor threshold for bromine is frequently cited between 0.05 ppm and 0.1 ppm—close to the legal PEL—olfactory fatigue occurs rapidly upon exposure. Personnel can quickly lose the sensory ability to detect rising vapor concentrations, making odor completely unreliable as a warning property. Consequently, institutional chemical hygiene programs require active engineering controls and direct-reading monitoring instruments, such as photoionization detectors (PIDs) calibrated with appropriate response factors or colorimetric detection tubes, during non-routine or pilot-scale operations.
Personal protective equipment and glove breakthrough standards
Selecting appropriate personal protective equipment (PPE) for bromine handling requires rigorous evaluation of chemical permeation resistance. Standard laboratory practices that rely on disposable nitrile or latex examination gloves represent a severe and potentially catastrophic hazard when manipulating liquid bromine.
Chemical degradation and permeation testing conducted by industrial hygiene researchers and glove manufacturers demonstrates dramatic differences across elastomer types:
- Viton (Fluoroelastomer): Viton provides the highest level of chemical permeation resistance against neat liquid bromine, exhibiting normalized breakthrough detection times exceeding 480 minutes (ASTM F739 rating of Level 6). Viton gloves (minimum 10 mil to 15 mil thickness) are the mandatory standard for direct handling, dispensing, and synthetic manipulation of liquid bromine.
- Silver Shield / 4H (Laminate Film): Polyethylene/ethylene vinyl alcohol laminates provide excellent barrier resistance against halogen permeation (>480 minutes breakthrough), making them ideal as protective under-gloves or for high-risk transfer procedures, although they offer limited tactile dexterity.
- Butyl Rubber: Butyl rubber exhibits moderate resistance to bromine vapor and dilute aqueous solutions (breakthrough times between 30 and 120 minutes depending on glove thickness), but is susceptible to swelling and degradation during prolonged liquid contact.
- Disposable Nitrile (Acrylonitrile Butadiene): Standard 4 mil to 8 mil disposable nitrile gloves provide virtually zero barrier protection against liquid bromine. Liquid bromine degrades and permeates disposable nitrile in less than 5 minutes, frequently causing the polymer to swell, turn dark red, and disintegrate while transferring bromine directly onto the wearer’s skin. Nitrile may only be used as a momentary secondary outer splash layer over Viton gloves to protect against superficial bench contamination.
- Neoprene and Natural Latex: Both materials react exothermically or soften rapidly upon contact with concentrated bromine and must never be used for primary chemical handling.
In addition to specialized gloves, laboratory personnel must wear indirect-vent chemical splash goggles meeting ANSI/ISEA Z87.1 requirements, paired with an 8-inch minimum polycarbonate face shield whenever decanting or pouring liquid bromine. Torso and limb protection requires a full-length, fire-resistant lab coat constructed of Nomex or heavy chemical-resistant treated cotton, supplemented by a heavy-duty vinyl or neoprene chemical apron. Open-toed shoes, porous canvas footwear, and synthetic leggings are strictly prohibited.
Physical properties, vapor density, and fume hood aerodynamic requirements
Understanding the unique physical and aerodynamic behaviors of bromine is essential for configuring engineering controls that prevent toxic exposures. Bromine possesses an extraordinary combination of high volatility, high liquid density, and heavy vapor density that dictates specialized handling protocols.
Key physical constants documented across manufacturer SDS specifications include:
- Boiling Point: 58.8°C (137.8°F), indicating rapid vaporization at elevated room temperatures.
- Melting / Freezing Point: -7.2°C (19°F), meaning bromine will freeze in refrigerated storage (4°C), requiring careful temperature stabilization before dispensing to avoid container rupture.
- Liquid Density / Specific Gravity: 3.102 g/cm³ at 25°C. Bromine is more than three times denser than water. A standard 1-liter bottle of bromine weighs approximately 3.1 kilograms (6.8 pounds), placing severe mechanical strain on glass bottles, carrying caddies, and laboratory apparatus.
- Vapor Pressure: 175 mmHg at 20°C (23.3 kPa), demonstrating substantial volatility under ambient conditions.
- Relative Vapor Density: 5.5 (Air = 1.0). Bromine vapor is five and a half times heavier than air.
The high relative vapor density of 5.5 has profound implications for chemical fume hood operation. When liquid bromine is exposed to air, the dense reddish-brown fumes do not disperse upward; instead, they immediately sink toward the hood work surface and flow along benchtop channels. If the fume hood’s lower aerodynamic baffles are obstructed by equipment, toxic bromine vapors will pool across the floor of the hood and spill over the lower airfoil into the laboratory breathing zone.
To ensure total containment, all open operations involving bromine must take place inside a certified chemical fume hood operating with an average face velocity of 80 to 120 feet per minute (fpm), with 100 fpm recognized as the optimal benchmark. The hood sash must be lowered to the designated operational height (typically 12 to 18 inches or lower). All equipment placed inside the hood must be elevated at least 2 inches above the work surface using lab jacks or slotted support stands to allow uninterrupted laminar airflow beneath the apparatus toward the rear lower exhaust slots.
Chemical incompatibilities, TRGS 510 storage class, and segregation rules
Bromine is a powerful oxidizing agent that undergoes violent, highly exothermic, and frequently explosive reactions upon contact with a broad spectrum of organic and inorganic laboratory reagents. Storing bromine within standard chemical cabinets alongside organic solvents or reducing agents invites severe disaster.
Critical chemical incompatibilities documented in SDS Section 10 include:
- Combustible Materials and Organic Solvents: Contact between liquid bromine and common organic solvents (e.g., diethyl ether, acetone, ethanol, tetrahydrofuran) can trigger immediate spontaneous ignition or violent thermal runaways. Alkenes, alkynes, and aromatic compounds undergo rapid, highly exothermic halogenation reactions that can violently eject reaction mixtures.
- Ammonia and Primary Amines: Mixing bromine with aqueous or anhydrous ammonia produces nitrogen tribromide (NBr₃) or related bromoamines, which are violently sensitive contact explosives capable of detonating upon slight mechanical agitation.
- Alkali and Alkaline Earth Metals: Elemental potassium, sodium, and lithium react explosively on contact with liquid bromine. Finely divided metal powders—including aluminum, titanium, magnesium, and zinc—burn vigorously in bromine vapor, producing metal bromide salts and massive thermal energy.
- Strong Reducing Agents: Hydrazine, hydroxylamine, sulfides, and phosphites undergo rapid, gas-generating exothermic oxidations that can pressurize closed systems and shatter reaction glassware.
- Moisture and Water: While bromine is partially soluble in water (~3.4 g/100 mL at 20°C, forming ‘bromine water’), the reaction generates hydrobromic acid (HBr) and hypobromous acid (HOBr). The resulting acidic mists aggressively attack structural metals, stainless steel ductwork, and cabinet hardware, necessitating corrosion-resistant exhaust systems similar to those required for formic acid chemical safety profiles.
Under European and international storage classification frameworks, such as the German Technical Rules for Hazardous Substances (TRGS 510), elemental bromine is typically assigned to Storage Class (Lagerklasse, LGK) 6.1B (Non-combustible acute toxic substances) or Class 8A (Corrosive substances). TRGS 510 joint storage matrices strictly prohibit co-storage of bromine with LGK 1 (Explosives), LGK 2A (Aerosols), LGK 3 (Flammable liquids), LGK 4.1A (Self-reactive substances), and LGK 5.2 (Organic peroxides).
In laboratory facilities, bromine must be stored in dedicated, corrosion-resistant acid/toxic storage cabinets equipped with active exhaust ventilation. Primary glass containers must be housed within secondary containment vessels constructed of fluoropolymers (PTFE or PFA), borosilicate glass, or lead-lined trays. Polyethylene and polypropylene secondary trays are acceptable only for short-term secondary containment, as halogen vapor diffusion causes gradual embrittlement and stress cracking of polyolefin plastics.
Manufacturer SDS comparison and primary document access
While all chemical manufacturers adhere to the standardized GHS format, subtle differences exist among commercial safety data sheets regarding product grades, packaging engineering, recommended glove specifications, and transport documentation. Laboratory managers and procurement specialists must review vendor-specific documentation before placing orders.
Major chemical manufacturers provide authoritative primary SDS documents for elemental bromine:
- MilliporeSigma (Sigma-Aldrich): Publishes SDS documentation for Reagent Grade Bromine (Product #207888, >=99.5% purity) and ACS Reagent Grade (Product #101948). The MilliporeSigma SDS provides rigorous European TRGS 510 storage class assignments (LGK 6.1B), explicit Viton glove barrier recommendations, and detailed aquatic ecotoxicity data (LC50 Daphnia magna: 1.07 mg/L over 48 hours). The document is accessible directly via the MilliporeSigma product portal.
- Fisher Chemical (Thermo Fisher Scientific): Supplies SDS documentation for Bromine Certified ACS (Catalog #B385-50, B385-250, and B385-1LB). The Fisher Scientific document emphasizes acute inhalation toxicity thresholds (Category 1), highlights lachrymatory properties in Section 2, and specifies specialized protective packaging requirements, including glass bottles with PTFE-lined cap inserts packaged inside sealed metal cans cushioned with inert vermiculite.
- Carl Roth GmbH: Provides European REACH-compliant SDS documentation (Product #5364, Bromine >=99.5% pure). The Carl Roth SDS details specific DNEL (Derived No Effect Level) worker inhalation thresholds (0.35 mg/m³ for systemic acute and chronic exposure) and PNEC (Predicted No Effect Concentration) environmental indicators, offering valuable quantitative benchmarks for European EHS auditors.
The dataset below compares the toxicological, regulatory, and engineering specifications across these leading manufacturer safety data sheets and federal agency monographs, providing a unified technical reference for laboratory safety officers.
Step-by-step spill neutralization and emergency decontamination protocols
Responding to a bromine spill demands immediate, disciplined chemical action. Because bromine vaporizes rapidly and attacks respiratory membranes, hesitation or improper neutralization techniques can rapidly escalate a minor bench incident into a building-wide hazmat emergency.
The universal chemical agent for neutralizing elemental bromine is aqueous sodium thiosulfate (Na₂S₂O₃), typically prepared as a 5% to 10% weight-to-volume solution and buffered with sodium carbonate (Na₂CO₃) or sodium bicarbonate (NaHCO₃). The chemical reaction is a redox reduction in which thiosulfate reduces molecular bromine to harmless, water-soluble bromide ions while being oxidized to sulfate and tetrathionate:
Na₂S₂O₃ + 4 Br₂ + 5 H₂O → 2 NaHSO₄ + 8 HBr
Because the generated hydrobromic acid is strongly acidic, adding sodium carbonate or bicarbonate buffers the solution to near-neutral pH, preventing secondary acid damage and toxic acid mist generation.
CRITICAL SAFETY WARNING: NEVER apply dry sodium thiosulfate powder directly onto liquid bromine. Mixing dry, solid thiosulfate powder with concentrated liquid bromine produces an uncontrolled, highly exothermic reaction that can boil unreacted bromine, causing violent spattering and massive vapor clouds. Neutralization must always be executed using an aqueous solution.
For small, manageable laboratory spills (less than 50 mL) occurring entirely inside a functional chemical fume hood, trained personnel should execute the following stepwise decontamination protocol:
- Evacuate Immediate Personnel & Lower Sash: Alert all laboratory occupants immediately. Lower the chemical fume hood sash to the minimum height necessary for arm access (approx. 6 to 8 inches) to maximize capture face velocity.
- Don Advanced PPE: Equip Viton chemical gloves (or double-glove with Viton over Silver Shield), indirect-vent splash goggles, full face shield, and chemical-resistant apron.
- Prepare Neutralizing Solution: Obtain a freshly prepared 5%–10% aqueous sodium thiosulfate solution buffered with 5% sodium bicarbonate. A pre-mixed, dedicated bromine spill neutralizing bottle should be stored within reach of the bromine storage area.
- Apply Neutralizer Inward from Edges: Slowly and gently pour the aqueous thiosulfate solution around the outer perimeter of the bromine spill, gradually working inward toward the center. This establishes a containment dike and prevents the heavy liquid from spreading across the bench.
- Monitor Colorimetric Endpoint: As the thiosulfate solution mixes with the liquid bromine, observe the dramatic color change. The dark reddish-brown color will fade through light orange and yellow, eventually becoming completely clear and colorless. Color clearance confirms that all toxic elemental bromine has been reduced to non-volatile bromide ions.
- Absorb and Package Decontaminated Slurry: Using inert absorbent pads or vermiculite, absorb the neutralized liquid. Transfer the wet absorbent into a heavy-duty polypropylene or high-density polyethylene (HDPE) waste container. Seal tightly and affix a hazardous chemical waste label stating ‘Neutralized Bromine Residue — Contains Sodium Bromide, Sodium Sulfate, and Excess Sodium Thiosulfate’.
- Wash and Decontaminate Work Surfaces: Thoroughly wash the contaminated benchtop, hood floor, and apparatus with warm water and laboratory detergent, followed by a final wipe-down with fresh thiosulfate solution.
If a bromine spill exceeds 50 mL, or if any volume of bromine spills outside a certified chemical fume hood, personnel must immediately pull the fire alarm, evacuate the laboratory suite, close all doors, and contact emergency response personnel and institutional EHS. Do not attempt unassisted cleanup of open-room spills.
Where bromine safety matters for labs, clinics, or supply decisions
The operational safeguards detailed in a bromine SDS directly impact daily workflow and financial decisions across multiple research and clinical environments. Far from being a mere compliance formality, SDS data drives procurement strategies, facility design, and analytical protocol development.
In academic and industrial synthetic organic chemistry laboratories, bromine is an indispensable electrophilic reagent utilized in brominations of aromatic rings, allylic and benzylic brominations (such as Wohl-Ziegler reactions using N-bromosuccinimide precursors), and the synthesis of pharmaceutical intermediates. Because bromine reacts violently with moisture to generate corrosive HBr, synthetic chemists must configure inert gas manifolds, Schlenk lines, and gas-scrubbing traps equipped with aqueous thiosulfate bubblers to neutralize exhaust vapors before they reach vacuum pump systems.
In water analysis and environmental testing facilities, bromine water solutions are routinely prepared to quantify chemical oxygen demand (COD), detect unsaturated hydrocarbons, and evaluate disinfectant by-products in municipal water supplies. Environmental labs must establish dedicated micro-dispensing protocols to minimize vapor generation during volumetric aliquoting.
For procurement officers, laboratory managers, and chemical hygiene officers, SDS review drives critical purchasing decisions:
- Specialized Packaging Requirements: Requisitioning smaller packaging volumes (e.g., 50 mL or 100 mL ampoules or coated glass bottles) rather than bulk 1-liter glass containers drastically reduces spill exposure risk and secondary containment costs.
- Dedicated Protective Gear Stocking: Procurement teams must maintain dedicated stocks of Viton gloves and pre-measured thiosulfate neutralization kits alongside every bromine order, ensuring bench workers are never forced to substitute inadequate nitrile gloves.
- Facility HVAC & Cabinet Maintenance: EHS officers use SDS physical data to audit fume hood exhaust duct materials, ensuring that exhaust stacks are constructed of halogen-resistant materials and located away from air intake vents on building rooftops.
Common misunderstandings regarding bromine laboratory safety
Decades of laboratory incident reviews reveal recurring misconceptions among research personnel regarding bromine behavior. Addressing these misunderstandings is essential for preventing catastrophic chemical exposures.
Key misunderstandings include:
- Misunderstanding 1: ‘Disposable nitrile gloves provide adequate splash protection for brief handling.’
Reality: Standard 4 mil to 8 mil disposable nitrile gloves offer virtually zero chemical barrier against liquid bromine. Neat liquid bromine degrades and permeates nitrile in less than 5 minutes. Workers wearing nitrile frequently suffer severe contact burns because the permeated bromine is trapped against the skin beneath the glove. Only Viton or Silver Shield gloves provide certified protection. - Misunderstanding 2: ‘Because bromine is non-flammable, it presents no laboratory fire risk.’
Reality: While elemental bromine does not sustain combustion itself, it is an aggressive, powerful oxidizer. Contact between liquid bromine and combustible materials (such as laboratory paper towels, cotton swabs, wooden bench fixtures, or organic solvents) can trigger immediate spontaneous ignition and explosive combustion. Bromine must be treated with the same fire-segregation discipline as concentrated nitric acid or organic peroxides. - Misunderstanding 3: ‘Bromine spills should be treated with dry chemical spill absorbent or neutralizing powder.’
Reality: Applying dry alkaline or reducing powders (such as dry sodium thiosulfate, dry carbonate, or clay-based floor dry) directly onto liquid bromine can generate an intense exothermic reaction that boils the bromine and violently spatters corrosive droplets into the room. Decontamination must strictly utilize aqueous buffered solutions applied from the edges inward. - Misunderstanding 4: ‘Personnel can rely on bromine’s sharp odor to detect hazardous leaks.’
Reality: Rapid olfactory fatigue occurs within moments of smelling halogen vapors. Furthermore, the human odor detection threshold (0.05–0.1 ppm) is approximately equal to the legal OSHA 8-hour PEL. Relying on smell to alert personnel of danger guarantees that toxic exposure has already occurred. - Misunderstanding 5: ‘Refrigerating bromine prevents vapor generation and makes it safer to handle.’
Reality: Bromine freezes at -7.2°C (19°F). While chilling liquid bromine reduces vapor pressure, freezing bromine in domestic-style laboratory freezers can crack glass bottles due to thermal stress upon uneven thawing. Furthermore, unvented spark-producing domestic freezers can ignite secondary solvent vapors present in the unit. Bromine should be stored in cool, ventilated, chemical-resistant cabinets (15°C to 25°C) rather than standard freezers unless an explosion-proof, temperature-monitored unit is specifically engineered for halogen service.
Frequently asked questions
What are the primary GHS hazard classifications for bromine?
Under GHS standards, elemental bromine is classified with the Signal Word DANGER and three pictograms: Corrosion (GHS05), Skull and Crossbones (GHS06), and Environment (GHS09). Its mandatory hazard classifications are Acute Toxicity Inhalation Category 1 (H330: Fatal if inhaled), Skin Corrosion/Irritation Category 1A (H314: Causes severe skin burns and eye damage), Serious Eye Damage Category 1 (H318: Causes serious eye damage), and Acute Aquatic Toxicity Category 1 (H400: Very toxic to aquatic life).
Which glove materials provide adequate protection against liquid bromine?
Viton (fluoroelastomer) gloves provide the highest chemical permeation resistance against liquid bromine, with breakthrough times exceeding 480 minutes (Level 6 protection). Laminate film gloves (Silver Shield / 4H) also provide superior chemical barrier protection. Standard disposable nitrile, neoprene, and latex gloves degrade and experience breakthrough in less than 5 minutes and are strictly prohibited for primary liquid bromine handling.
What is the OSHA Permissible Exposure Limit (PEL) for bromine?
The OSHA Permissible Exposure Limit (PEL) for bromine is an 8-hour time-weighted average (TWA) of 0.1 ppm (0.7 mg/m³), codified in 29 CFR 1910.1000 Table Z-1. NIOSH recommends a matching Recommended Exposure Limit (REL) of 0.1 ppm TWA, a 15-minute Short-Term Exposure Limit (STEL) of 0.3 ppm (2 mg/m³), and designates 3 ppm as Immediately Dangerous to Life or Health (IDLH).
How should a small laboratory bromine spill be neutralized safely?
A small bromine spill inside a chemical fume hood must be neutralized using a freshly prepared 5% to 10% aqueous sodium thiosulfate (Na₂S₂O₃) solution buffered with sodium bicarbonate or sodium carbonate. Pour the aqueous solution gently around the perimeter of the spill, working inward until the dark reddish-brown color completely disappears, indicating reduction to non-volatile bromide ions. Never apply dry sodium thiosulfate powder directly onto liquid bromine, as this causes violent exothermic spattering.
Why must bromine be stored separately from organic solvents and ammonia?
Bromine is an intense oxidizing agent that can spontaneously ignite combustible organic solvents like acetone, ethanol, and diethyl ether upon contact. Furthermore, mixing bromine with ammonia or primary amines generates nitrogen tribromide, a shock-sensitive contact explosive. Under TRGS 510 Storage Class 6.1B guidelines, bromine must be segregated in dedicated, vented, corrosion-resistant acid/toxic storage cabinets.
Sources
- National Institute for Occupational Safety and Health (NIOSH). NIOSH Pocket Guide to Chemical Hazards: Bromine (CAS 7726-95-6). Centers for Disease Control and Prevention. https://www.cdc.gov/niosh/npg/npgd0064.html (accessed 2026-11-16).
- Occupational Safety and Health Administration (OSHA). 29 CFR 1910.1000 Table Z-1: Limits for Air Contaminants — Bromine. United States Department of Labor. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1000TABLEZ1 (accessed 2026-11-16).
- National Center for Biotechnology Information (NCBI). PubChem Compound Summary for CID 24408: Bromine. National Library of Medicine. https://pubchem.ncbi.nlm.nih.gov/compound/Bromine (accessed 2026-11-16).
- MilliporeSigma (Sigma-Aldrich). Safety Data Sheet: Bromine, Reagent Grade (Product Number 207888). Merck KGaA. https://www.sigmaaldrich.com/US/en/sds/sial/207888 (accessed 2026-11-16).
- Fisher Scientific (Thermo Fisher Scientific). Safety Data Sheet: Bromine, Certified ACS (Catalog Number B385-50). Thermo Fisher Scientific Inc. https://www.fishersci.com/store/msds?partNumber=B38550 (accessed 2026-11-16).
- International Programme on Chemical Safety (IPCS). International Chemical Safety Card (ICSC 0107): Bromine. World Health Organization and International Labour Organization. https://www.ilo.org/dyn/icsc/showcard.display?p_card_id=0107 (accessed 2026-11-16).
- Federal Institute for Occupational Safety and Health (BAuA). TRGS 510: Storage of Hazardous Substances in Non-Stationary Containers. Federal Ministry of Labour and Social Affairs (Germany). https://www.baua.de (accessed 2026-11-16).
Data: Bromine Laboratory Safety & Manufacturer SDS Specification Matrix
Comparative technical dataset compiling physical, toxicological, and chemical safety specifications for bromine across primary manufacturer SDSs (MilliporeSigma and Fisher Chemical) and regulatory monographs (OSHA and NIOSH).
| Parameter | MilliporeSigma Reagent Grade | Fisher Chemical Certified ACS | OSHA / NIOSH Regulatory Monograph |
|---|---|---|---|
| CAS & UN Identification | CAS 7726-95-6, UN 1744 | CAS 7726-95-6, UN 1744 | CAS 7726-95-6, UN 1744, RTECS EF9100000 |
| GHS Signal Word & Pictograms | Danger (GHS05, GHS06, GHS09) | Danger (GHS05, GHS06, GHS09) | Danger (Corrosion, Skull and Crossbones, Aquatic) |
| Primary Hazard Statements | H314, H330, H400 | H314, H330, H400 | H314, H330, H400 |
| Inhalation Toxicity Classification | Acute Toxicity Category 1 (Fatal if inhaled) | Acute Toxicity Category 1 (Fatal if inhaled) | Inhalation Hazard Zone A, IDLH 3 ppm |
| Skin Corrosion Classification | Category 1A (Severe burns and eye damage) | Category 1A (Severe burns and eye damage) | Severe dermal corrosive, rapid blistering |
| Occupational Exposure Limits | TWA 0.1 ppm, STEL 0.2 ppm | TWA 0.1 ppm, STEL 0.3 ppm | OSHA PEL TWA 0.1 ppm, NIOSH REL TWA 0.1 ppm, STEL 0.3 ppm |
| Liquid Density at 20°C / 25°C | 3.102 g/cm³ | 3.12 g/cm³ | 3.102 g/cm³ (Specific Gravity 3.1) |
| Vapor Pressure at 20°C | 175 mmHg (23.3 kPa) | 175 mmHg | 175 mmHg (Vapor Density 5.5) |
| Mandatory Glove Material | Viton (>480 min breakthrough) | Viton or Silver Shield / 4H | Viton / Butyl (disposable nitrile prohibited) |
| Recommended Chemical Neutralizer | Aqueous sodium thiosulfate (5%–10%) | Aqueous sodium thiosulfate with carbonate buffer | Aqueous sodium thiosulfate solution (never dry powder) |
Sources
- MilliporeSigma SDS: Bromine Reagent Grade (207888) (accessed 2026-11-16)
- Fisher Scientific SDS: Bromine Certified ACS (B385) (accessed 2026-11-16)
- NIOSH Pocket Guide to Chemical Hazards: Bromine (accessed 2026-11-16)
- OSHA 29 CFR 1910.1000 Table Z-1: Bromine (accessed 2026-11-16)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.