A carbon dioxide safety data sheet (SDS) classifies CO2 as a gas under pressure (GHS hazard statement H280, signal word Warning), not as a flammable or toxic substance, and the supplier SDSs add that it can displace oxygen in enclosed spaces and cause rapid suffocation. For lab staff the practical content is storage of cylinders upright and below 52 °C (125 °F), ventilation where the gas can accumulate, and the 5,000 ppm OSHA exposure limit.

Short answer

Carbon dioxide (CAS 124-38-9) is a colourless, odourless gas. OSHA’s chemical database lists its synonyms as carbonic acid gas and dry ice, a molecular weight of 44.0, a vapour density of 1.53 (air = 1) and a sublimation point of -109 °F. Under the GHS it is classified as a liquefied gas under pressure (H280). Two of the three supplier SDSs compared below also describe it as an asphyxiant in high concentrations, and the Linde US sheet gives it the classification “simple asphyxiant”. The full side-by-side comparison of the three sheets is in the data table at the end of this page.

Definition and scope: what a carbon dioxide SDS covers

An SDS is the 16-section document a supplier issues under the OSHA Hazard Communication Standard (29 CFR 1910.1200). The Airgas sheet for compressed CO2 states that the material is considered hazardous under that standard. Which sheet applies depends on the form you hold: compressed or liquefied gas in a cylinder, refrigerated liquid in a dewar or bulk tank, or solid dry ice each have their own supplier SDSs. This page covers the cylinder-gas sheets from three suppliers. Dry ice is mentioned only where the same hazards carry over; for contact injury from solid CO2, see what happens if you touch dry ice.

The same structure applies to other cylinder gases. The sibling guide nitrogen gas SDS reads a nitrogen sheet section by section; the asphyxiation logic is similar, but CO2 differs in being heavier than air and in carrying its own exposure limits.

Reading the carbon dioxide SDS in practice

Section 2: hazard classification and label elements

All three sheets read for this page assign the pictogram-and-text combination of a liquefied gas under pressure: signal word Warning and H280, “Contains gas under pressure; may explode if heated”. The sheets differ in what they add. Airgas lists two “hazards not otherwise classified”: it may displace oxygen and cause rapid suffocation, and it may increase respiration and heart rate. Linde US lists the same two as supplemental statements (OSHA-H01 and CGA-HG03), adds a frostbite statement (CGA-HG01) and classifies the gas as a simple asphyxiant (SIAS). The Air Liquide Malaysia sheet lists “asphyxiant in high concentrations” and “contact with liquid may cause cold burns/frostbite” under other hazards that do not result in classification.

Two practical points follow. First, CO2 is not flammable and the sheets do not classify it as acutely toxic; the hazard that matters in a lab is pressure plus oxygen displacement. Second, a sheet that omits a hazard line is not saying the hazard is absent: Airgas does not use the term simple asphyxiant in its classification block, yet its own text states the gas may displace oxygen and cause rapid suffocation.

Precautionary statements (P-statements)

The Airgas sheet prints only one: P410 + P403, “Protect from sunlight. Store in a well-ventilated place”, and marks the prevention, response and disposal statements as not applicable. The Air Liquide Malaysia sheet also prints only P410 + P403. The Linde US sheet is the longest: P202 (do not handle until all safety precautions have been read and understood), P261 (avoid breathing gas), P262 (do not get in eyes, on skin, or on clothing), P271 + P403 (use and store only outdoors or in a well-ventilated place) and P280 (wear protective gloves, clothing, eye and face protection). If your institution requires a label with a specific set of P-statements, check which supplier’s sheet your cylinder actually ships with.

Sections 7 and 8: storage, handling, ventilation and PPE

Storage guidance is consistent in direction and differs in numbers. Airgas and Linde US both state that cylinders should not be exposed to temperatures above 52 °C (125 °F); Air Liquide Malaysia states that the container should be kept below 50 °C in a well-ventilated place. All three describe keeping cylinders upright and secured, with valve caps or guards in place. Airgas adds that cylinders should not be dragged, rolled, slid or dropped, that a hand truck should be used, that a back-flow preventer belongs in the piping, and that the valve should be closed after each use. Linde US adds that full and empty cylinders are stored separately and that stock is used first-in, first-out.

On engineering controls the sheets are not equivalent. Airgas states that good general ventilation should be sufficient to control worker exposure. Air Liquide Malaysia calls for adequate general and local exhaust ventilation and says oxygen detectors should be used where asphyxiating gases may be released. Linde US notes the gas is heavier than air, tends to accumulate near the floor of an enclosed space, and that oxygen-deficient atmospheres can occur near the floor, so the space should be ventilated and oxygen verified before entry.

PPE is likewise scenario-based rather than uniform. Airgas calls for chemical-resistant gloves and safety glasses with side shields where a risk assessment indicates them. Linde US specifies work gloves and metatarsal shoes for cylinder handling, safety glasses for handling cylinders and cold insulating gloves when transfilling or breaking transfer connections. Air Liquide Malaysia refers to cold insulating gloves (EN 511) and goggles (EN 166) for transfilling or breaking connections, and mechanical-protection gloves (EN 388) when handling containers.

Sections 10 and 13: incompatibilities and disposal

The incompatibility field shows the widest variation. The Linde US sheet lists alkali metals, alkaline earth metals, acetylide-forming metals, chromium, titanium above 550 °C, uranium above 750 °C and magnesium above 775 °C, and notes that electrical discharge or high temperature can produce carbon monoxide and oxygen. The Airgas sheet leaves its incompatible-materials entry blank in the text read, and Air Liquide Malaysia gives “None” with a pointer to ISO 11114 for compatibility information. For disposal, Airgas directs surplus product to a licensed waste disposal contractor, Linde US says not to attempt to dispose of residual or unused quantities and to return the container to the supplier, and Air Liquide Malaysia says unused product should be returned to the supplier in the original container and that small amounts may be vented to atmosphere only in a well-ventilated place where accumulation cannot become dangerous.

Exposure limits for carbon dioxide

Exposure limits are where a reader most often finds an apparent contradiction: the Airgas sheet’s exposure-limit table prints “None” for carbon dioxide, while OSHA, NIOSH and the other suppliers list numbers. The numbers come from regulators and standard-setting bodies, not from the supplier, so a supplier can omit them. The table collects the values read from the OSHA Occupational Chemical Database (last updated 05/23/2024, which also reports the NIOSH values) and the Linde US and Air Liquide Malaysia sheets.

Limit Value Where it is stated
OSHA PEL, 8-hour TWA 5,000 ppm (9,000 mg/m³) OSHA database; Linde US SDS
NIOSH REL, TWA 5,000 ppm OSHA database
NIOSH REL, short-term (STEL) 30,000 ppm (54,000 mg/m³) OSHA database
Cal/OSHA PEL-TWA and PEL-STEL 5,000 ppm and 30,000 ppm OSHA database
ACGIH TLV, TWA and STEL 5,000 ppm and 30,000 ppm (TLV basis: asphyxia) Linde US SDS; Air Liquide Malaysia SDS
IDLH 40,000 ppm OSHA database; Linde US SDS
UK WEL, TWA and STEL 5,000 ppm and 15,000 ppm Air Liquide Malaysia SDS (citing EH40/2005)

Note that the UK short-term limit (15,000 ppm) is half the US NIOSH and ACGIH short-term value (30,000 ppm). A lab working under both regimes should read the value that applies to its jurisdiction. The OSHA database lists the skin notation as N and does not list carbon dioxide as a carcinogen, and names direct-reading detector tubes and infrared instruments among the on-site methods for measuring it.

Where it matters for labs and supply decisions

Carbon dioxide reaches a lab in several forms, and each pulls different parts of the SDS to the front.

  • Cylinders (incubators, gassing, calibration). Sections 7 and 8 govern: upright and secured storage, valve caps, temperature ceiling, and the floor-level accumulation warning for small rooms and cold rooms. Cylinder dimensions are covered in compressed gas cylinder sizes.
  • Dry ice (sample shipping and cold packaging). Solid CO2 sublimes, so the gas-accumulation hazard applies to closed rooms, walk-in cold rooms and vehicles. Carbon dioxide, solid, is also a regulated shipping item; see Class 9 dangerous goods for the transport category.
  • Refrigerated liquid. The frostbite and cold-burn statements on the Linde US and Air Liquide Malaysia sheets apply to contact with the liquid or cold equipment; the cold-insulating glove requirement on both sheets applies at transfilling and when breaking connections.

When SDS files are collected for a chemical inventory, record which supplier’s sheet and which revision belongs to each cylinder. The three sheets compared here carry revision dates of 3/28/2025 (Airgas), 3/24/2022 (Linde US) and 7/31/2024 (Air Liquide Malaysia), and they do not agree on every field.

Common misunderstandings

“Carbon dioxide is harmless because it is in the air.”

The sheets treat the pure gas as hazardous: Airgas notes the OSHA Hazard Communication Standard hazardous status, and all three describe pressure and oxygen displacement. The limits above (5,000 ppm TWA, 40,000 ppm IDLH) are the regulators’ own numbers for workplace air.

“It is not on the SDS, so it is not a hazard.”

As shown above, an empty exposure-limit table (Airgas) or an unclassified asphyxiant line does not remove the hazard. Compare the supplier text with the regulator’s value.

“Carbon dioxide hazards are only about breathing.”

The sheets also cover pressure (H280, may explode if heated), cold contact (frostbite from liquid), and the heavier-than-air behaviour that makes enclosed low spaces the risk point. Hazard classification is separate from fire: Air Liquide Malaysia’s transport entry describes it as a liquefied, non-flammable gas.

“All suppliers’ sheets say the same thing.”

They do not, as the cross-walk shows: P-statements, storage ceilings (52 °C or 50 °C), incompatibility lists and exposure-limit tables all differ. Use the sheet supplied with your own cylinder.

Sources

Data: Carbon dioxide cylinder-gas SDS cross-walk: Airgas, Linde US and Air Liquide Malaysia

Side-by-side comparison of how three supplier safety data sheets for carbon dioxide gas present GHS classification, signal word, precautionary statements, asphyxiant listing, storage temperature ceiling, incompatible materials and revision date. Compiled by reading each supplier's published SDS text.

Carbon dioxide cylinder-gas SDS cross-walk: Airgas, Linde US and Air Liquide Malaysia
SDS fieldAirgas (US, v8.02)Linde (US, v2.3)Air Liquide (Malaysia)
Revision date3/28/202503/24/20227/31/2024
GHS classificationGases under pressure, liquefied gas (H280)Press. Gas (Liq.) H280 and Simple asphyxiant (SIAS)Gases under pressure, liquefied gas (H280)
Signal wordWarningWarningWarning
Precautionary statements printedP410+P403 only; prevention, response, disposal not applicableP202, P261, P262, P271+P403, P280 (plus response statements)P410+P403 only
Oxygen displacement / asphyxiant wordingMay displace oxygen and cause rapid suffocation (hazards not otherwise classified)OSHA-H01 may displace oxygen and cause rapid suffocation; NFPA special hazard SAAsphyxiant in high concentrations (other hazards, no classification)
Storage temperature ceiling52 C (125 F)52 C (125 F)50 C
Incompatible materials listedEntry blankAlkali metals, alkaline earth metals, acetylide-forming metals, chromium, titanium, uranium, magnesium at stated temperaturesNone; refers to ISO 11114
Exposure limits in the sheetNone listedACGIH TWA 5000 ppm, STEL 30000 ppm; OSHA PEL 5000 ppm; IDLH 40000 ppmTRGS 900 and UK WEL 5000 ppm TWA; UK STEL 15000 ppm; ACGIH 5000/30000 ppm
Disposal instructionLicensed waste disposal contractorReturn container to supplier; do not dispose of residual quantitiesReturn unused product to supplier; may be vented in a well-ventilated place

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about Carbon Dioxide SDS: GHS Hazards, Exposure Limits and Storage

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →