Skip to main content
v2026.11,986 entries · CC-BY 4.0

Centrifugal Pump Cavitation: Causes, Types and Prevention

How cavitation forms in centrifugal pumps, why NPSHR means NPSH3, how air aspiration differs, and which fix matches which symptom.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

Cavitation in a centrifugal pump is the formation of vapour bubbles in the liquid where local pressure falls below the liquid’s vapour pressure, followed by the violent collapse of those bubbles when the flow carries them into higher-pressure regions. In a centrifugal pump the bubbles usually form at the impeller eye, where pressure is lowest, and collapse as the liquid is pressurised toward the discharge. It is prevented by keeping the net positive suction head available (NPSHA) above the net positive suction head required (NPSHR), and fixed by finding which of five distinct causes is operating.

What is the process of cavitation?

Wilo’s pump-basics training describes the sequence this way: the liquid accelerates into the impeller eye, local pressure falls below the vapour pressure, and vapour bubbles form. The flow then carries them toward the discharge, and they collapse as the pressure rises. If a bubble collapses close to a surface such as the impeller or a guide vane, the collapse can damage that surface. Pumps and Systems describes the same event as bubbles that “violently collapse or implode” on entering higher-pressure areas.

Three details matter for diagnosis:

  • Where it starts. The impeller eye is the lowest-pressure region, so that is where bubbles first appear (Wilo).
  • What it needs. Cavitation occurs when the available NPSH is lower than the required NPSH (Wilo). Pumps and Systems states the rule in the other direction: NPSHa should always exceed NPSHr.
  • What makes it worse. Higher flow raises the NPSH the pump requires, a higher liquid temperature raises the vapour pressure, and high fluid velocity (often from overspeed) lowers local pressure (Wilo).

How a centrifugal pump is built, and where pressure is lowest

A centrifugal pump moves liquid by adding energy through a rotating impeller inside a casing. Liquid enters the impeller at the eye, is accelerated by the vanes, and leaves into the casing, where velocity is converted into pressure. Because the liquid speeds up as it enters the eye, the pressure there drops. That local drop, not the pressure measured at the suction flange, is what vapour formation responds to, which is why a pump can cavitate even when a gauge on the suction line reads a healthy value.

KSB’s pump lexicon adds that the head of a centrifugal pump is proportional to the square of pump speed, one reason overspeed operation appears among the causes Wilo lists. For related equipment families, see our guides to turbomachinery, the progressing cavity pump and the rotary vane pump, which work on different principles and do not fail in the same way.

What are the three types of centrifugal pumps?

Centrifugal pumps are commonly grouped by impeller type into radial, mixed-flow and axial. KSB’s lexicon states that a centrifugal pump’s impeller “may be a radial, mixed flow or axial impeller,” and that the choice depends on the pump’s specific speed. Specific speed is derived from flow and head at the best efficiency point (BEP) and lets impellers of different sizes be compared.

Impeller type Specific speed (KSB) Flow path Construction notes (KSB)
Radial Low specific speeds Radial through the impeller Open (no shroud) or closed (with shroud) channels
Mixed-flow (“diagonal”) A higher specific-speed range Between radial and axial Open or closed channels
Axial (propeller) The highest specific speeds Axial Can be cast in one piece with the hub, or have blades attached to the hub so pitch can be adjusted

KSB also notes that as specific speed rises, the flow path shifts from radial toward axial. Volute casings must grow as specific speed rises while the flow stays radial, and at high specific speeds the flow can only leave axially, for example through tubular casings. The impeller class matters for cavitation because the suction behaviour (NPSHR) belongs to the specific pump and impeller, and you read it from the manufacturer’s curve for that pump rather than from the type name.

NPSHA versus NPSHR: the comparison that decides cavitation

KSB’s NPSH article separates two quantities. NPSHA is what the system supplies: the total pressure at the suction reference point, referred to the impeller centre, minus the vapour pressure, with head losses in the suction line included. NPSHR is what the pump needs. Comparing the two tells you whether cavitation is expected.

NPSHR is not a single physical threshold, which is the part most competing explainers omit. KSB reports that the commonly agreed NPSHR is NPSH3, the suction condition at which the pump’s head drops by 3 percent. Other criteria exist, such as the incipient NPSHi, below which bubbles begin to form. KSB states that if NPSHA is above NPSHi no bubbles form, but that determining criteria other than NPSH3 needs demanding and expensive testing. In practice, a pump operating with NPSHA between NPSH3 and NPSHi is therefore not necessarily free of cavitation: the 3 percent head drop is a performance criterion, not a guarantee that the impeller is undamaged.

KSB further notes that the location of cavitation depends on flow. Suction-side cavitation appears when the flow is below the shock-free flow rate, pressure-side cavitation when it is above, and the vapour trail lengthens as NPSHA falls, especially at low flow and in overload.

Types of cavitation and air aspiration

Pumps and Systems distinguishes five conditions that people loosely call cavitation: vaporization, turbulence, vane syndrome, internal recirculation and air aspiration. The data table below lists each with its stated cause and fix. The distinction that matters most for troubleshooting is between true vapour cavitation and air aspiration. In vaporization the bubbles are the pumped liquid’s own vapour, produced by low pressure. In air aspiration, air enters through failing valves or loose joints and forms bubbles that then collapse under pump pressure. The noise can be similar, but raising NPSHA will not cure a leak at a joint.

What are the symptoms and the damage?

Wilo lists rumbling, cracking or popping noises, increased vibration, lower efficiency and output, fluctuating pressure readings, irregular power consumption, pitting or erosion on the impeller and casing, and more frequent repairs from premature wear. Pumps and Systems adds damage to the shaft and other internal parts and erosion and corrosion at weakened points. Wilo states that cavitation is a leading cause of pump failure. Atlas Copco describes the noise as like pumping rocks and advises shutting the pump down at the first sign.

How do you fix cavitation?

Work from symptom to cause rather than applying every fix at once. The table below links what you observe to the cause and the remedy each source names.

Observation Likely cause Remedy stated by the source Source
Crackling noise and vibration, pump far above its normal flow Operating away from the best efficiency point; higher flow raises required NPSH Run the pump close to its BEP; size the pump on maximum, normal and minimum flow Wilo; Pumps and Systems
Noise with the discharge valve closed or nearly closed Internal recirculation Maintain minimum flow with bypass lines, control valves or variable speed pumping Pumps and Systems
Problems after a screen, filter or strainer has loaded up Suction restriction lowering inlet pressure Keep filters, strainers and valves clean and fully open Wilo
Bubbles or noise with a loose joint or low liquid level Air aspiration Seal pipe connections, maintain minimum submergence and suction head, prime properly, avoid intake vortices Pumps and Systems
Cavitation that appears as the liquid warms Higher temperature raises vapour pressure Cool the fluid, which also raises NPSHA Wilo; Pumps and Systems
High suction lift or long, small-bore suction line with many bends Low inlet pressure and high suction losses Lower the pump or raise the supply level, enlarge or shorten the suction line, use long-radius bends and full-bore valves Wilo; Pumps and Systems

If a pump is already running with audible cavitation, Atlas Copco’s guidance for its pumps is to shut down at the first sign and, where applicable, reduce engine speed. Continuing to run a cavitating pump is how modest erosion becomes impeller replacement.

How is cavitation prevented in pumps?

Prevention is design and operating discipline, not a single device. The measures named by Wilo and Pumps and Systems fall into four groups:

  1. Raise NPSHA. Lower the pump relative to the source or raise the supply level, shorten or enlarge the suction line, and cool the liquid.
  2. Cut suction losses. Short, straight suction piping with few bends, long-radius bends, full-bore valves, and limited screens and filters.
  3. Keep the operating point sensible. Stay near the best efficiency point and above minimum flow; keep fluid velocity within recommended limits.
  4. Keep air out and boost inlet pressure if needed. Seal connections, maintain submergence and prime properly; Wilo lists an inducer as an option when inlet pressure needs a boost.

Pumps and Systems also lists impeller design, liners and monitoring among its reduction measures. Because the vane syndrome and turbulence conditions come from the impeller being too large for its housing or from poorly suited fittings at the inlet, they are design and selection problems, which operating adjustments only partly address.

Who deals with pump cavitation

Plant and facility engineers, maintenance technicians and pump specifiers meet it most often, including in research facilities that run circulating, cooling-water and transfer pumps. The practical point from the sources is that the condition is diagnosed from the system (suction piping, liquid temperature, valve positions, air leaks) as much as from the pump itself, so checking NPSHA against NPSHR before replacing a damaged pump addresses the cause rather than only the symptom.

Common mistakes

  • Treating every noisy pump as the same problem; air aspiration and vapour cavitation need different fixes.
  • Reading NPSHR as a hard line rather than as the NPSH3 convention (KSB).
  • Running with the discharge valve closed, which Pumps and Systems identifies as a common cause of internal recirculation.
  • Letting a strainer or filter clog, which lowers inlet pressure (Wilo).
  • Sizing only for maximum flow instead of maximum, normal and minimum flow (Pumps and Systems).

FAQ

What are the three types of centrifugal pumps?

Radial, mixed-flow and axial, grouped by impeller design and specific speed (KSB). See the table above.

How do you fix cavitation?

Identify the cause first, then act on it: raise NPSHA, reduce suction losses, restore minimum flow, seal air leaks or cool the liquid. The symptom-to-remedy table above maps each observation to the source’s remedy.

What is the process of cavitation?

Local pressure falls below the liquid’s vapour pressure, bubbles form, and they collapse violently when carried into higher pressure.

How is cavitation prevented in pumps?

By keeping NPSHA above NPSHR, minimising suction losses, operating near the best efficiency point and keeping air out of the suction line.

For wider context on equipment practice, see the lab operations hub, and for another pump with air- and fluid-handling constraints, the guide to peristaltic pump tubing.

Sources

Data: Pump cavitation types: cause and stated remedy

Five cavitation conditions in centrifugal pumps compiled from a single trade-engineering article, giving each condition's stated cause and the remedy the article ties to it or to the closest related guidance.

Pump cavitation types: cause and stated remedy
Cavitation typeStated causeStated remedySource
VaporizationLiquid accelerates into the impeller eye, pressure drops and the liquid boilsKeep NPSHa above NPSHr: lower the pump or raise suction level, enlarge suction piping, cut fitting losses, limit screens and filters, cool the fluidPumps and Systems
TurbulenceElbows, valves, filters or strainers unsuited to the liquid or flow create vortices and pressure differences at the inletGeneral advice: avoid turbulent flow at the intake; long-radius bends and full-bore valvesPumps and Systems
Vane syndromeImpeller too large or housing coating too thick reduces clearance, raising velocity and lowering pressureImpeller design and pump sizingPumps and Systems
Internal recirculationPump cannot discharge at the required rate, e.g. closed discharge valve, so liquid recirculates around the impellerMaintain minimum flow with bypass lines, control valves or variable speed pumpingPumps and Systems
Air aspirationAir enters through failing valves or loose joints and forms bubbles that collapse under pump pressureSeal pipe connections, maintain submergence and suction head, prime properly, avoid intake vorticesPumps and Systems

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Centrifugal Pump Cavitation: Causes, Types and Prevention

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →