Cone Penetration Test (CPT): How It Works, Measurements and Limits

How the cone penetration test works under ASTM D5778: rate, measurements, formulas, quality checks and why soil behaviour type is not soil classification.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

The cone penetration test (CPT) pushes an instrumented cone on the end of cylindrical push rods into the ground at a constant rate, usually 20 mm/s, and records tip resistance, sleeve friction and, with a piezocone, pore water pressure as it goes. The result is a near-continuous record of subsurface conditions that engineers read as stratigraphy and, with site-specific correlations, as soil properties for earthworks and foundations.

Definition and scope

ASTM D5778-20, Standard Test Method for Electronic Friction Cone and Piezocone Penetration Testing of Soils, defines the test as pushing a cone at the end of a series of cylindrical rods into the ground at a constant rate. The same standard notes that the procedure is also called cone sounding. The test is a field investigation method: the work happens in the ground at the site, not at a laboratory bench, which is why it sits in this site’s practice-oriented guides on protocols and techniques rather than in bench-science material. For the wider discipline see what civil engineering is and the civil and structural engineering discipline page.

The standard has deliberate boundaries. ASTM D5778 applies to electronic friction cones. It does not cover hydraulic, pneumatic or free-fall cones, and mechanical cones are handled by a separate ASTM standard, D3441. It also notes that offshore systems may differ from the onshore equipment it describes. At the international level, ISO 22476-1:2022 is the current ISO standard for the electrical cone and piezocone test; its 2012 edition was withdrawn in January 2023.

Friction cone and piezocone

A friction cone measures tip resistance and sleeve friction. A piezocone adds a pore pressure sensor. D5778 states that pore pressure can be measured when the piezocone is properly saturated, and that a dissipation test (stopping the push, unloading the rods and recording pore pressure against time) gives consolidation and permeability information. If the pore pressure settles to a constant value, that value is the equilibrium pore pressure, u0. The standard also allows further sensors on the same string: an inclinometer (recommended), seismic, resistivity, electrical conductivity, dielectric and temperature sensors.

How the test is used in practice

D5778 specifies that the cone is advanced at a constant rate of 20 mm/s while an electric transducer measures the force on the tip. Tip resistance, qc, is the vertical force divided by the cone base area. Readings are taken at penetration intervals of no more than 50 mm, and the standard notes that 20 mm or 10 mm intervals give better resolution.

Two cone sizes are standard: a 10 cm2 cone (maximum diameter 36.1 mm) and a 15 cm2 cone (maximum diameter 44.2 mm). The standard notes that 5 cm2 field cones and 1 cm2 laboratory research cones also exist, and that the friction sleeve is sized to match the cone.

D5778 describes the purpose of the data in two parts. First, the test gives a detailed record of tip resistance that can show stratigraphy, homogeneity, depth to firm layers and voids, and at suitable sites it is a rapid means of determining subsurface conditions. Second, with site-specific correlations, the measurements can be turned into engineering properties for earthworks and foundation design. Those correlations are local judgement, not part of the test method itself.

What the test measures, and how the numbers relate

The data table below sets out the measured and derived quantities in one place, with the formula or definition and the source for each. Two points explain most of the notation. Pore pressure at the shoulder position directly behind the tip (u2) is the standard location for the pore pressure reading, and the measured tip resistance is corrected for pore pressure acting on unequal areas to give the corrected tip resistance qt. In sands the correction is negligible, so qt equals qc; in soft clays it matters. The normalised parameters Qt, Fr and Bq then remove the effect of overburden stress so that soils at different depths can be compared on one chart.

Soil behaviour type is not soil classification

A common use of CPT data is to infer soil behaviour type from a chart. The Robertson normalised chart plotting Qtn against Fr is described in the open-access paper on cone penetration indices for soil behaviour type prediction as the most reliable of the commonly used charts. The index Ic (Robertson and Wride) approximates that chart with circles, and the same paper reports that it diverges significantly from it, which is why refined indices have been proposed.

The paper is also clear that soil behaviour type is not soil identification. The largest disagreements with the Unified Soil Classification System (USCS) come in mixed soils, where partial drainage during the push changes the response. Sleeve friction is considered less accurate than tip resistance and pore pressure, and thin layers are blurred because each reading reflects a zone of influence around the cone, not just the soil at the tip. A CPT profile therefore does not replace samples and laboratory classification where grain size or index properties are needed.

CPT and the standard penetration test

The standard penetration test (SPT) is a different in-situ method, driven by a falling hammer with a split-spoon sampler, and it is not covered by D5778. The CPT’s main contrast is the continuous electronic record at fine depth intervals instead of discrete blow-count intervals. Unlike the SPT, the CPT does not recover a soil sample.

Where it matters for site investigation and research practice

For researchers and project teams, the practical value of a CPT is reproducibility of the record. Because the measured values are defined by the test method itself, the quality controls in the standard are central to whether a sounding can be trusted. The same discipline of documented, calibrated, repeatable procedure applies to bench work; see the dictionary entries on the standard operating procedure and methods reproducibility.

Quality checklist drawn from ASTM D5778

  • Baselines. Zero-load readings are recorded before and after each sounding.
  • Calibration. The transducers are calibrated periodically against the interval the standard and the project specification set.
  • Piezocone saturation. Air must be removed from the pore pressure system; the filter element is replaced and the ports flushed after every sounding.
  • Verticality and rod condition. Bent push rods and drift give unreliable data, so inclination is monitored during the push.
  • Interferences. Coarse deposits with particles near the cone diameter can cause refusal, deflection or damage, and lithified deposits may cause refusal.

Common misunderstandings

  • “CPT identifies the soil.” It infers behaviour from resistance and pore pressure. The soil behaviour type chart does not give a USCS classification, especially in mixed soils.
  • “Any cone will do.” D5778 covers electronic friction and piezocones only; mechanical cones fall under D3441, and hydraulic, pneumatic and free-fall cones are outside it.
  • “Sleeve friction is as reliable as tip resistance.” The open-access literature treats sleeve friction as the less accurate channel.
  • “Thin layers show sharply.” The zone of influence around the cone averages across thin layers.
  • “CPT works everywhere.” Gravelly or lithified ground can stop or damage the cone.

Frequently asked questions

What is the difference between a CPT and a piezocone test?

A piezocone test is a CPT with a pore pressure sensor added to the friction cone. ASTM D5778 covers both, and the added sensor allows pore pressure and dissipation records alongside tip resistance and sleeve friction.

How fast is the cone pushed?

ASTM D5778 specifies a constant rate of 20 mm/s.

How often are readings taken?

Readings are taken at penetration length intervals of no more than 50 mm; 20 mm or 10 mm intervals give better resolution.

Can a CPT tell me the soil type?

It indicates soil behaviour type through normalised charts such as the Robertson Qtn-Fr chart. It is not a soil classification, and the largest disagreements with USCS occur in mixed soils.

What sizes of cone are used?

The standard sizes are 10 cm2 and 15 cm2. Smaller 5 cm2 field and 1 cm2 laboratory research cones exist.

Sources

  • ASTM D5778-20, Standard Test Method for Electronic Friction Cone and Piezocone Penetration Testing of Soils, catalogue entry, https://www.astm.org/d5778-20.html.
  • Cone penetration index for soil behaviour type prediction (open access), https://pmc.ncbi.nlm.nih.gov/articles/PMC9300735/ (checked 2026-11-14).
  • ISO 22476-1:2022, Geotechnical investigation and testing, Field testing, Part 1: Electrical cone and piezocone penetration test, title and edition status per national standards body listings (checked 2026-11-14).

Data: CPT measured and derived quantities with definitions and source clauses

Compiled from ASTM D5778-20 and an open-access paper on CPT soil behaviour type indices: each row gives a quantity reported or derived in cone penetration testing, its symbol, its definition or formula, and the source section it is drawn from.

CPT measured and derived quantities with definitions and source clauses
QuantitySymbolDefinition or formulaSource
Tip resistanceqcVertical force on the cone tip divided by the cone base areaASTM D5778-20, section 4.1
Corrected tip resistanceqtqt = qc + (1 - a) u2, where a is the cone area ratio; in sands qt equals qcPMC9300735
Sleeve frictionfsFriction measured on the friction sleeve behind the cone; considered less accurate than tip or pore pressureASTM D5778-20; PMC9300735
Pore pressure behind the tipu2Pore pressure at the standard location immediately behind the cone tipASTM D5778-20, section 13.5; PMC9300735
Normalised tip resistanceQtQt = (qt - sigma_vo) / sigma'_voASTM D5778-20, section 13.5
Normalised friction ratioFrFr = fs / (qt - sigma_vo)ASTM D5778-20, section 13.5
Pore pressure ratioBqBq = u2 / (qt - sigma_vo)ASTM D5778-20, section 13.5
Equilibrium pore pressureu0Constant pore pressure value reached in a dissipation testASTM D5778-20, section 1.3

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Cone Penetration Test (CPT): How It Works, Measurements and Limits

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →