Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General product information only, not medical advice and not a procedure guide.
Short answer
A Desmarres retractor is a handheld manual ophthalmic instrument used as an eyelid (lid) retractor. In the United States it falls under FDA product code HNI (“Retractor, Ophthalmic”) and the manual ophthalmic surgical instrument regulation, 21 CFR 886.4350, which classifies the generic type as Class I with an exemption from 510(k) premarket notification, subject to the limitations in 21 CFR 886.9. Listings differ on whether the instrument arrives sterile and single-use or must be sterilized before each use.
Definition and scope
21 CFR 886.4350 defines a manual ophthalmic surgical instrument as “a nonpowered, handheld device intended to aid or perform ophthalmic surgical procedures.” The regulation’s list of included generic types has no entry named “Desmarres”; it names, among others, the eyelid clamp, the ophthalmic retractor, the ophthalmic hook and the iris retractor clip. Devices registered in the FDA’s AccessGUDID database under the name “Desmarres” carry product code HNI, so the name is a manufacturer-level product description inside the broader ophthalmic retractor category (checked 2026-10-31).
This page covers what the instrument is, how it is classified and how to read a product listing. It does not describe surgical technique.
How it is used in practice
The general function, as described in product listings, is to hold back an eyelid while a clinician works on or around the eye. Technique, positioning and patient-specific decisions belong to the surgeon and the manufacturer’s instructions for use (IFU), and are outside this page.
Related instruments in the same regulation
Lid retractors and the ophthalmic retractor entry
The Desmarres retractor sits with other eyelid-holding instruments. For the speculum family see eyelid speculum types and FDA class; for the wider range of eye instruments see ophthalmic surgical instruments; for retractors across specialties see what is a surgical retractor.
Iris retractors and iris hooks
21 CFR 886.4350 lists “iris retractor clip” and “ophthalmic hook” as separate generic types within the same classification. They are named separately from the ophthalmic retractor and from the eyelid clamp, so a search for iris retractors or iris hooks leads to different products from a Desmarres lid retractor, even though all sit under the same Class I regulation.
Where it matters for supply decisions
The table compares two real AccessGUDID records, both with product code HNI, checked on 2026-10-31. It shows why two products with the same name can need different handling. Treat it as a checklist of fields to read in any listing, not as a recommendation.
| Field | Blink Medical “Desmarres Retractor 14mm” (model 90-9013) | Aurora Surgical “Desmarres Lid Retractor” (AS1-242T) |
|---|---|---|
| Description in record | No description | “Desmarres Lid Retractor, Size 2, Titanium” |
| Packaged as sterile | Yes | No |
| Requires sterilization prior to use | No | Yes |
| For single use | Yes | No |
| Clinically relevant size field | “No Device Sizes” (14 mm appears only in the name) | “No Device Sizes” (Size 2 appears only in the description) |
| Contains natural rubber latex | No | No |
What the comparison shows
- Sterile single-use and reusable versions both exist. The first record is sterile and single-use; the second is non-sterile, requires sterilization before use and is not single-use. Reprocessing steps for a reusable instrument come from the manufacturer’s IFU.
- Size labels are not standardized in the database. Both records leave the structured size field empty, so a size such as “14mm” or “Size 2” is whatever the manufacturer wrote in its own name or description. Check what a given supplier’s number means before treating sizes from different makers as interchangeable.
- Regulatory class does not vary by version. Both records share the HNI product code, so both fall under the same Class I, 510(k)-exempt category in 21 CFR 886.4350.
Common misunderstandings
- “Class I and exempt means no rules.” General controls still apply, and the exemption is subject to the limitations in 21 CFR 886.9.
- “A Desmarres retractor is a speculum.” The regulation lists ophthalmic specula and the ophthalmic retractor as separate generic types.
- “All Desmarres retractors are reusable steel.” The two records above show a sterile single-use device and a non-sterile reusable titanium one.
FAQ
What is a Desmarres retractor?
A handheld manual ophthalmic instrument sold as an eyelid retractor, registered in AccessGUDID under product code HNI, “Retractor, Ophthalmic”.
What is the FDA class of a Desmarres retractor?
The generic type in 21 CFR 886.4350 is Class I (general controls), exempt from 510(k) premarket notification subject to the limitations in 21 CFR 886.9.
Are Desmarres retractors sterile?
It depends on the product. One AccessGUDID record is packaged sterile and single-use; another requires sterilization before use and is reusable. Read the IFU and the listing for the specific model.
What do the sizes mean?
The two AccessGUDID records checked have no structured size value. The size appears in the manufacturer’s own name or description, so confirm what each maker’s number means.
What are iris retractors and iris hooks?
21 CFR 886.4350 lists the iris retractor clip and the ophthalmic hook as their own generic types, distinct from the eyelid-oriented instruments above.
Sources
- U.S. eCFR, 21 CFR 886.4350, Manual ophthalmic surgical instrument, checked 2026-10-31.
- NLM AccessGUDID, device record 05060480408562 (Blink Medical), checked 2026-10-31.
- NLM AccessGUDID, device record 08175700104081 (Aurora Surgical), checked 2026-10-31.
- Related CASRAI reading: FDA 510(k) premarket notification.