An EEG cap with electrodes is a head-worn textile cap with labelled holes at set scalp positions, into which electrodes are fitted so a recording can be made from the skin of the scalp. The electrodes themselves are regulated in the United States as cutaneous electrodes, a Class II device type. Clinic staff, lab buyers and students use this page to tell cap types apart: by hole layout (10-20, 10-10, 10-5) and by head-circumference size.
What it is
An EEG cap holds electrodes in a fixed arrangement on the head so the same scalp positions are used from one recording to the next. Under US federal regulation, an electrode of this kind falls under 21 CFR 882.1320: a cutaneous electrode is “an electrode that is applied directly to a patient’s skin either to record physiological signals (e.g., the electroencephalogram) or to apply electrical stimulation,” and it is classified as Class II (performance standards). That classification applies to the electrode; the regulation text does not describe the cap fabric.
Who uses it: neurophysiology and sleep clinic staff, research laboratories running EEG studies, and students learning scalp electrode placement.
How it is built
One manufacturer’s textile cap line, MCScap, is sewn from elastic material with labelled electrode holes, so it fits the head closely. Its large openings are designed for access to the scalp and to the electrodes, and they also improve ventilation. The cap material is described as retaining conductive gel or paste under each electrode, according to the maker’s product page. For what the gel does at the skin, see conductive gel; for the electrode types that go in the holes, see silver/silver chloride electrodes and dry EEG electrodes.
Types and variants
Caps differ mainly in which international electrode-position system their holes follow. The 10-20 layout is explained in the 10-20 system guide, and how layout density relates to recording channels is covered in EEG channels. For a headband-style alternative, see EEG headband. The table lists the cap models in one manufacturer’s textile-cap range (source: MKS, checked 2026-10-31).
| Model (MKS MCScap range) | Hole layout / feature stated by the maker |
|---|---|
| MCScap 10-10 | Textile cap labelled to the international 10-10 system |
| MCScap 10-20 with fixing rings | Printed textile cap with pre-installed fixing rings, international 10-20 system |
| MCScap-51 with fixing rings | Printed textile cap with pre-installed fixing rings, international 10-10 modified |
| MCScap 10-5 | Textile cap labelled to the international 10-5 system |
The same range also lists further models (10-10 black, 10-10 with fixing rings, LIGHT and 5-5). The maker states that, depending on the model, the electrode mounting holes correspond to the 10-20, 10-10 or 10-5 system. Its COVER and DISPOSABLE COVER products are protective covers, not caps. The related term “EEG net” is outside the scope of this page, which covers the textile cap form only.
Sizes that matter
The same manufacturer states that 12 size options fit head circumferences from 24 to 66 cm, with the size identified by the colour of the cap material or seam. That range belongs to this one maker’s line and should not be assumed for other brands. Cap size is therefore chosen by head circumference, measured against the maker’s own size chart.
| Specification | Value stated | Source |
|---|---|---|
| Number of cap sizes | 12 | MKS textile caps page |
| Head circumference range | 24 to 66 cm | MKS textile caps page |
| Size identification | Colour of the cap material or seam | MKS textile caps page |
How to choose
Two criteria can be taken from the published specifications. First, the hole layout (10-20, 10-10 or 10-5) must match the electrode positions the recording protocol calls for. Second, the size must match the head circumference. Everything else, including electrode count and electrode material, is stated by the maker per model and should be taken from that model’s own documentation.
Safe use and handling basics
Because the electrode sits directly on the skin, it is regulated as a cutaneous electrode (21 CFR 882.1320). Refer to the electrode and cap maker’s instructions for use. This page gives no individual medical advice.
Common mistakes
- Treating a size range from one maker as universal: the 24 to 66 cm span above is MKS-specific.
- Choosing a layout by electrode count alone rather than by the positions a protocol requires.
- Confusing a protective cover with a cap: the maker lists its covers separately from its caps.
FAQ
What is an EEG cap with electrodes?
It is a textile cap with labelled holes at standard scalp positions that holds electrodes against the head for EEG recording. The electrodes are cutaneous electrodes under 21 CFR 882.1320 (Class II).
How are EEG cap sizes chosen?
By head circumference. One manufacturer offers 12 sizes covering 24 to 66 cm and marks them by material or seam colour.
What do 10-20, 10-10 and 10-5 mean on a cap?
They name the international electrode-position system the holes follow. See the 10-20 system guide for the base layout.
Related supplies for diagnostic work are listed under diagnostic, monitoring and imaging supplies.
Sources
- US eCFR, 21 CFR 882.1320 Cutaneous electrode, https://www.ecfr.gov/current/title-21/part-882/section-882.1320 (checked 2026-10-31).
- MKS, Textile caps (MCScap), https://mks.ru/en/products/textile-caps (checked 2026-10-31).