Written and maintained by CASRAI Editorial Board
Published
On this page
Emergy is the available energy of one kind that was previously used, directly and indirectly, to make a product or service. It is measured in emjoules, and most studies express everything in solar emjoules (seJ). Where energy asks how much is left to do work, emergy asks how much was already spent to make the thing. The concept comes from the systems ecologist Howard T. Odum, and it is used to compare ecological, industrial and economic flows on a single energy-based scale.
Definition and scope
Ortega’s course notes on Odum’s emergy evaluation (University of Campinas, read 2026-11-12) define emergy as “available energy of one kind previously required directly and indirectly to make a product or service”, and describe it as a way of evaluating “the work previously done” to make that product or service. Two points follow from the definition:
- It counts history, not content. A product’s emergy is not the energy it could release. It is the accumulated available energy used up along every pathway that led to it. The same notes state that “there is no emergy in degraded energy”: heat that has already lost its ability to do work does not add emergy.
- It needs a reference kind of energy. Emergy is expressed relative to one chosen kind of energy. Most applications use solar emjoules (seJ), so that wind, rain, fuel, labour and materials can all be stated as the solar energy their formation required.
The notes also warn that it is “quite invalid” to treat joules of one kind of energy as equivalent to joules of another when comparing contributions without converting them. That is the problem emergy tries to solve: a joule of sunlight, a joule of coal and a joule of electricity differ in how much prior work stands behind them.
How an emergy evaluation is done
The same source lists the working steps of an evaluation:
- Define the system window and draw a systems diagram, usually in energy-language symbols.
- Identify the important pathways and assemble data for each line item (flows and storages).
- Multiply each energy flow or storage by its transformity to obtain emergy values.
- Divide emergy by an emergy/money ratio to express it in emdollars (em$), the portion of economic product attributable to that emergy contribution.
- For mixed flows, trace the emergy of each input separately until its last available energy is used up, then add the results.
The notes give a worked case: a partial emergy table for 84 hectares of mangroves in Lee County, Florida. It lists tidal exchange (transformity 2.4 E4 sej/J), freshwater inflow (4.9 E4 sej/J) and rain used (1.8 E4 sej/J), with a total of about 320 thousand em$ of real wealth and 2,556 thousand em$ of value attracted. The notes caution that this table is a partial analysis and rests on an assumed regional emergy investment ratio of 7/1 for Florida.
Core quantities: emergy, empower and transformity
Three quantities carry most of the vocabulary, and they are easy to confuse. The data table below sets them beside the sustainability indicators, with each definition tied to the source that states it.
Emergy versus empower
Empower is emergy per unit time (emjoules per unit time), so it is a flow, whereas emergy is an amount. A forest’s stored emergy and the empower it receives each year are different measures.
Transformity
Transformity is the emergy of one kind of available energy required, directly and indirectly, to make one joule of another kind (emjoules per joule, sej/J). It places a flow in an energy hierarchy: the more transformations behind a form of energy, the higher its transformity. By definition, the transformity of sunlight absorbed by the Earth is 1.0 (Wikipedia, “Emergy”, read 2026-11-12).
Specific emergy and mass emergy
For materials, the notes speak of emergy per unit mass. They illustrate it with lead, whose emergy per mass rises as its concentration rises. Emergy-based studies often report such figures in seJ per gram.
Sustainability indicators: EYR, ELR and the sustainability index
Penn State’s course EME 807 (read 2026-11-12) defines three ratios for an emergy-evaluated system, where Y is a product directly related to the function of the system, F is non-local (purchased) resources, N is non-renewable local resources and R is renewable local resources:
- Emergy yield ratio (EYR) = Y / F. It characterises the system’s capability to exploit local resources, renewable or not. The more the system depends on imported resources or services (higher F), the lower the EYR.
- Environmental loading ratio (ELR) = (F + N) / R. More renewable use in the denominator gives a lower ELR, which the course describes as beneficial for the environment.
- Sustainability index (SI) = EYR / ELR, combining the two. Wikipedia lists the same index as the emergy sustainability index (ESI).
A related ratio in Ortega’s notes is the net emergy ratio: the emergy of the yield Y divided by the emergy of feedback F from the economy. The notes observe that because human services carry high emergy, the net emergy contribution of some biomass-ethanol and solar technologies can be small or negative.
Penn State describes its own treatment as “just a single illustration” and notes that results may not answer other questions that different stakeholders have, and that studies should state objectives, definitions and assumptions.
Where emergy came from, and why baselines matter
According to the Wikipedia article on emergy (a secondary source; dates below are as that article reports them), Odum studied ecosystem energy flows in the 1950s and 1960s, first stated the concept in 1973, and published energy quality factors in 1975 on a fossil-fuel basis, later on coal equivalents and by 1977 on a solar basis. In the early 1980s the work used “embodied energy” before moving to “embodied solar calories” and “transformity ratios”, because other groups used “embodied energy” differently. In 1986 David Scienceman suggested the term “emergy” and the unit “emjoule”.
The reference baseline, the total annual emergy of the biosphere used to anchor all transformities, has been revised several times. Because the revisions rescale values, a transformity quoted from one era should not be compared directly with one from another.
| Period | Baseline or reference as reported |
|---|---|
| 1983 to 1986 | Global annual sources of 9.44E24 solar joules per year; fossil fuels set at 40,000 seJ/J |
| 2000 to 2016 | Biosphere emergy revised to 15.83E24 seJ/yr; coal about 6.7E4 seJ/J |
| 2016 to present | Biosphere emergy revised to 12.0E24 seJ/yr; earlier values adjusted by 1.27 (from the 9.44 basis) and 0.76 (from the 15.83 basis) |
Where it matters for labs and sustainability studies
Emergy is an accounting framework used in environmental and sustainability research, not a laboratory procedure. For laboratory and research-operations readers it is mainly something to recognise when it appears in a sustainability study of a facility, a process or a supply chain, and to read critically. Our guide to life cycle inventory covers a different, widely used accounting approach, and the dictionary term on laboratory equipment lifecycle assessment and the guide to lab sustainability place impact accounting in a lab setting. Emergy results answer a different question from those methods, so numbers should not be mixed between them.
A checklist for reading an emergy study
Each item below comes from a limitation stated in the sources above.
- Which baseline? Check the biosphere emergy baseline (9.44, 15.83 or 12.0 E24 seJ/yr) and whether transformities were converted to a common one.
- Which transformity method? Ortega’s notes record that ten ways of calculating transformities have been suggested, so results depend on the method chosen.
- Double counting? The notes state that care has to be taken not to double count the same emergy when flows recombine.
- Averages applied to services? Allocating emergy by an average does not evaluate many services correctly, because some services are unpaid and transformities vary widely.
- Observed or theoretical transformity? Observed values can be much higher than theoretical minimums in new or inefficient systems; the two answer different questions.
- Scope stated? Penn State’s guidance is that objectives, definitions and assumptions must be stated; a ratio without them is hard to interpret.
Common misunderstandings
“Emergy is just embodied energy.”
The term grew out of “embodied energy”, but the early-1980s shift to “transformity” and the 1986 coining of “emergy” came because other groups used “embodied energy” in different ways. Emergy is stated in a reference energy kind and weighted by energy quality.
“A joule is a joule.”
Emergy theory holds that joules of different kinds are not equivalent. Critics disagree: Wikipedia reports that many find it counterintuitive that a calorie of sunlight is not equivalent to a calorie of fossil fuel, and that critics including Sciubba (2010) argue emergy analysis conflicts with the Second Law of thermodynamics. Others argue the sunlight required to produce a quantity of oil cannot be measured objectively, and economists object that it disregards market values. Supporters, per the same article, describe the aim as an ecocentric valuation that supplements rather than replaces economic value.
“Emdollars are market prices.”
Emdollars are emergy divided by an emergy/money ratio. Ortega’s notes give a United States ratio of 1.33 E12 sej per dollar, derived from total emergy use divided by gross product, and note that emdollar values are usually larger than market values because economic values only cover the services involved.
“A higher or lower ratio settles the question.”
The ratios depend on how F, N and R are classified and on the system boundary. Treat them as one lens, not a verdict.
FAQ
What does emergy mean?
It is the available energy of one kind that was previously used, directly and indirectly, to make a product or service, usually expressed in solar emjoules (seJ).
What is the unit of emergy?
The emjoule, most often the solar emjoule (seJ). Transformity is in seJ per joule, empower in emjoules per unit time, and specific or mass emergy per unit mass such as seJ per gram.
Who developed emergy?
Howard T. Odum developed the underlying energy-quality ideas; David Scienceman suggested the name “emergy” in 1986, as reported by the Wikipedia article on emergy.
Is emergy accepted in mainstream economics and thermodynamics?
The Wikipedia article states it has been controversial within academe, including in ecology, thermodynamics and economics; see the criticisms above.
Sources
- Ortega, E. Emergy evaluation (course notes based on Odum), University of Campinas, www2.unicamp.br/fea/ortega/agroecol/emergy.htm, read 2026-11-12.
- Penn State, EME 807, emergy indicators, courses.ems.psu.edu/eme807/node/761, read 2026-11-12.
- Wikipedia, “Emergy” (secondary source, used for history, baseline revisions and criticisms, attributed above), en.wikipedia.org/wiki/Emergy, read 2026-11-12.
Data: Emergy quantities and sustainability indicators: definitions, units and variables compared
Compiled from course notes on Odum's emergy evaluation (University of Campinas) and Penn State EME 807: each emergy quantity or indicator with its definition, formula or unit, and the source that states it.
| Measure | Definition or formula | Unit | Source |
|---|---|---|---|
| Emergy | Available energy of one kind previously required directly and indirectly to make a product or service | emjoule (usually solar emjoule, seJ) | Ortega, University of Campinas |
| Empower | Emergy flow per unit time | emjoule per unit time | Ortega, University of Campinas |
| Transformity | Emergy of one kind of available energy required to make one joule of another kind | seJ per joule | Ortega, University of Campinas |
| Net emergy ratio | Emergy of the yield Y divided by the emergy of feedback F from the economy | dimensionless ratio | Ortega, University of Campinas |
| Emergy yield ratio (EYR) | EYR = Y / F, where Y is a product related to the system function and F is purchased non-local resources | dimensionless ratio | Penn State EME 807 |
| Environmental loading ratio (ELR) | ELR = (F + N) / R, where N is non-renewable local and R is renewable local resources | dimensionless ratio | Penn State EME 807 |
| Sustainability index (SI) | SI = EYR / ELR | dimensionless ratio | Penn State EME 807 |
Sources
- Ortega, Emergy evaluation course notes, University of Campinas (accessed 2026-11-12)
- Penn State EME 807, emergy indicators (accessed 2026-11-12)
Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.