General product and regulatory information only. This page is not medical advice and does not describe how to use any airway device on a patient.
Short answer
An esophageal obturator airway (EOA) is an emergency ventilation device that blocks the esophagus so that positive pressure ventilation goes to the trachea. Under 21 CFR 868.5650 it is a closed-end, semirigid esophageal tube attached to a face mask. FDA classifies it as Class II under product code CAO, “Airway, Esophageal (Obturator)”.
Definition and scope
The federal regulation defines the device in one sentence. According to 21 CFR 868.5650(a) in the eCFR (checked 2026-10-31), an esophageal obturator is “a device inserted through a patient’s mouth to aid ventilation of the patient during emergency resuscitation by occluding (blocking) the esophagus, thereby permitting positive pressure ventilation through the trachea.” The same paragraph states that the device “consists of a closed-end semirigid esophageal tube that is attached to a face mask.”
Two features of that wording set the scope of the term. First, the regulation names the esophagus as the structure the device blocks, which is why it is called an obturator. Second, the face mask is part of the identified device, so the regulatory description is a tube-plus-mask assembly rather than a tube alone. This page uses the regulation’s wording as its definition and does not extend it to other airway devices.
How it is described in the regulation and in practice
The regulatory description of intended use is limited to emergency resuscitation: the device aids ventilation by occluding the esophagus so that ventilation reaches the trachea. The regulation does not give instructions for use, and neither does this page. Anyone who needs procedural detail should consult a manufacturer’s instructions for use and the training standards of their own clinical or emergency medical services program.
For historical context, an ACEP Now article on the 50-year evolution of emergency airway management (checked 2026-10-31) describes the EOA as the emergency medical services airway before the early 1980s, “a co-esophageal blocker married to a face mask” that “still had all the deficiencies of mask ventilation.” The article calls it “a good vomit directional device” but says it “was not a significant improvement in ventilation or oxygenation over mask ventilation.” It also reports that the Combitube later “became the default airway solution for EMS agencies.” The article does not state that the EOA was directly replaced by that device, and this page does not claim it.
The FDA record in one place
The regulatory identity is easier to find when the identifiers sit together. The table below combines the eCFR text and the openFDA device classification record (last updated 2026-10-19, checked 2026-10-31).
| Field | Value | Source |
|---|---|---|
| Regulation | 21 CFR 868.5650, “Esophageal obturator” | eCFR |
| Device name in FDA classification | Airway, Esophageal (Obturator) | openFDA classification |
| Product code | CAO | openFDA classification |
| Device class | Class II (performance standards) | eCFR; openFDA lists device class 2 |
| Review panel / specialty | AN, Anesthesiology | openFDA classification |
| Life-sustain or life-support flag | Y | openFDA classification |
| GMP exempt flag | N | openFDA classification |
| Implant flag | N | openFDA classification |
| Third-party review flag | N | openFDA classification |
The openFDA service carries its own disclaimer that its data are unvalidated and should not be used to make decisions about medical care. Treat the record as a pointer to the regulatory identity of the device, and confirm any decision against the current regulation and FDA databases.
Related concepts
The regulation and the classification record each cover a single device type. Other airway topics on CASRAI are separate subjects, and the table below only points to them without comparing performance.
| Topic | Why it is related | Page |
|---|---|---|
| Tracheostomy tube | Another airway device, but one that goes into the trachea | What is a tracheostomy tube |
| LMA and endotracheal tube | Other airway devices covered on CASRAI | LMA vs ETT |
| Video laryngoscope | Equipment used in airway management, not an airway device itself | Video laryngoscope |
Where it matters for labs, clinics and supply records
A device that is no longer in routine use can still appear in legacy inventories, old equipment lists, regulatory databases and historical emergency medical services documents. The identifiers above give a record-matching checklist drawn from the sources cited:
- Match on the FDA device name, “Airway, Esophageal (Obturator)”, and on product code CAO rather than on a brand or an abbreviation.
- Match on the regulation number, 21 CFR 868.5650, which is the citation that appears in the classification record.
- Note the flags in the record: life-sustain or life-support Y, GMP exempt N, implant N.
- Check whether the item described is a tube with a face mask, which is the regulation’s description, or a different airway device that happens to be stored nearby.
For how FDA treats consensus standards in device review, see the CASRAI term FDA recognized consensus standards.
Common misunderstandings
“Obturator” means the same thing as any airway tube
It does not. In 21 CFR 868.5650 the term refers to a closed-end tube that occludes the esophagus and is attached to a face mask. The word describes what the tube does to the esophagus, not a general category of airway device.
The regulation proves the device is in current use
It does not. A regulation and a product code show how FDA classifies a device type. They do not show how often it is used. The ACEP Now article cited above describes the EOA as the EMS airway before the early 1980s.
Product code CAO covers every airway device
It does not. CAO is the code for “Airway, Esophageal (Obturator)” only; the openFDA record for it lists a single regulation, 21 CFR 868.5650.
Frequently asked questions
What is an esophageal obturator airway?
It is a device identified in 21 CFR 868.5650 as a closed-end semirigid esophageal tube attached to a face mask, used to aid ventilation during emergency resuscitation by blocking the esophagus.
How does FDA classify it?
As Class II (performance standards) under 21 CFR 868.5650, product code CAO, with Anesthesiology (AN) as the review panel, per the eCFR and the openFDA classification record checked on 2026-10-31.
What is product code CAO?
CAO is the FDA product code whose device name is “Airway, Esophageal (Obturator)”.
Is this page medical advice?
No. It gives regulatory and product-identity information only, and it contains no instructions for placing or using the device.
Sources
- eCFR, 21 CFR 868.5650 Esophageal obturator, checked 2026-10-31.
- FDA openFDA, device classification record for product code CAO, data last updated 2026-10-19, checked 2026-10-31.
- ACEP Now, Emergency medicine’s 50-year evolution of airway management, checked 2026-10-31 (historical context only).