EZ-IO: Needle Sizes, Drill, Kit Parts and FDA Class

EZ-IO explained as a device: 15, 25 and 45 mm needle sets, the reusable driver, kit parts, MR Conditional labeling and FDA Class II identity.

Written and maintained by CASRAI Editorial Board

Published · Last updated

On this page

General product and regulatory information for laboratory, clinic and supply staff. It is not medical advice and not a procedure guide; always follow the manufacturer’s current instructions for use (IFU).

Short answer

EZ-IO is the Teleflex (Arrow) intraosseous vascular access system: a reusable cordless driver (the “drill”) plus single-use, sterile needle sets in three lengths, 15 mm, 25 mm and 45 mm, all 15 gauge. FDA cleared it in 510(k) K180395 as a Class II device under 21 CFR 880.5570, product code FMI. Needle length is matched to labeled patient weight, and the IFU says depth markings, not weight alone, are the most accurate guide to correct needle selection.

Definition and scope

The FDA 510(k) summary for K180395 names the product the “EZ-IO Intraosseous Vascular Access System” and describes it as a driver plus a needle set made of a stylet and a catheter, intended to allow intraosseous infusion. The submitter is Arrow International, a Teleflex subsidiary. The device is listed under the regulation for a hypodermic single lumen needle (21 CFR 880.5570), Class II, and K180395 cites K141117 as its predicate. This page covers the product’s components, labeled needle sizes and regulatory identity only. Insertion sites, technique and drug administration are clinical topics governed by the IFU and by clinical protocols, and are outside this page.

What is in the system

EZ-IO needle sets

Per the Teleflex IFU (document 8088B Rev 02, English, PDF dated 2021-08-23), a needle set comprises a cannula with a Luer-lock connection, a stylet and a safety cap. The needles are 15 gauge, 304 stainless steel, supplied sterile and non-pyrogenic, and are intended for use with the EZ-IO Power Driver. K180395 adds that the hubs are polycarbonate with a color additive and that black lines on the needle set serve as depth markers. The IFU states that needle sets are single use only and must not be recapped or reassembled after separation.

EZ-IO drill (Power Driver)

People searching “ez io drill” are looking for the driver. K180395 describes it as a reusable cordless driver powered by lithium batteries with a battery-power indicator light. It is the only reusable component named in the 510(k) summary; the needle sets are not.

EZ-IO kit contents

“EZ-IO kit” is not a single defined configuration in the FDA or Teleflex documents. K180395 states that an EZ-Connect extension set (a needleless connector with a Luer lock adapter) is included with every needle set, and that the EZ-Stabilizer dressing is an optional securement accessory. Teleflex’s product listing for the 25 mm needle set also notes that the listing is not a substitute for the IFU.

EZ-IO needle sizes

The labeled weight ranges in the IFU and in K180395 agree with each other:

Needle set Labeled patient weight Color family in Teleflex listing Gauge and material
15 mm 3-39 kg Pink 15 gauge, 304 stainless steel
25 mm 3 kg or over Blue 15 gauge, 304 stainless steel
45 mm 40 kg or over Yellow 15 gauge, 304 stainless steel

Source: Teleflex EZ-IO IFU, FDA K180395 summary and the Teleflex needle set product listing (full links under Sources).

K180395 gives the 15 gauge diameter as 0.071 in (1.8 mm). The IFU states that black depth marks on each cannula function as depth measuring guides, and that the most accurate determinant of correct needle selection is use of depth markings rather than weight alone.

How the EZ-IO differs from “an IO needle” in general

“IO needle” is a generic phrase for any intraosseous needle. The EZ-IO is one branded system, and the 510(k) places it under the general hypodermic single lumen needle regulation rather than a category of its own. When a procurement or clinical engineering team compares products, the regulatory identity above (Class II, 21 CFR 880.5570, FMI) is the part that can be checked against FDA records; other manufacturers’ systems have their own 510(k) numbers and labeling.

Where it matters for labs, clinics and supply decisions

MRI labeling

The IFU labels the needle sets “MR Conditional.” The stated conditions are a static magnetic field of 1.5 T or 3 T, a maximum spatial field gradient of 4,000 G/cm (40 T/m), and a maximum whole-body averaged specific absorption rate of 2.0 W/kg in Normal Operating Mode. Under those conditions the IFU reports a maximum temperature rise of 5.1 C or less after 15 minutes of continuous scanning, and an image artifact extending approximately 6.3 cm from the device with spin-echo or gradient-echo imaging at 3 T. These conditions apply to the scanner setup; confirm them against the current IFU.

Common misunderstandings

  • Color is not size by itself. Color families in the Teleflex listing map to the 15, 25 and 45 mm lengths, but the IFU identifies depth markings as the more accurate selection guide.
  • The drill is reusable; needles are not. The driver is reusable; the IFU states needle sets are single use only.
  • “EZ-IO kit” is not one thing. Needle set, driver, EZ-Connect and stabilizer are described as separate components.

For related device pages, see what an IV catheter is, what a hypodermic needle is, what a central venous catheter is, what an IV start kit contains and arterial line vs central line.

FAQ

What are the EZ-IO needle sizes?

Three lengths, all 15 gauge: 15 mm (labeled 3-39 kg), 25 mm (3 kg or over) and 45 mm (40 kg or over), per the Teleflex IFU and FDA K180395. The IFU says black depth markings are the most accurate determinant of correct needle selection.

What is the EZ-IO drill?

It is the EZ-IO Power Driver: a reusable cordless driver powered by lithium batteries with a battery-power indicator light, used with the single-use needle sets.

What comes in an EZ-IO kit?

A needle set (cannula with Luer lock, stylet, safety cap) ships with an EZ-Connect extension set. The EZ-Stabilizer dressing is an optional accessory, and the driver is a separate reusable item.

Is the EZ-IO MRI safe?

The IFU labels it MR Conditional, not MR Safe, with the field strength, gradient and SAR limits listed above.

Sources

Date checked: 2026-10-31.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · free to try

Ask about EZ-IO: Needle Sizes, Drill, Kit Parts and FDA Class

2 free questions a day, no account.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →