Skip to main content
v2026.11,986 entries · CC-BY 4.0

FARSITE: Fire Area Simulator, How the Model Works, Inputs and Limits

What FARSITE is, how it grows a fire perimeter, the raster and weather inputs it needs, and the limits stated in its own documentation.

Written and maintained by CASRAI Editorial Board

Published

On this page

FARSITE (Fire Area Simulator) is a two-dimensional, deterministic wildland fire growth model developed by Mark Finney at the USDA Forest Service Missoula Fire Sciences Laboratory. Given maps of terrain, fuel and canopy plus weather and wind streams, it projects how a fire perimeter spreads over time, and it reports the spread rate and fireline intensity along that perimeter. It is distinct from the “Farsite” distributed file system described in a 2002 USENIX OSDI paper.

Definition and scope

The model is documented in Finney’s research paper FARSITE: Fire Area Simulator: model development and evaluation (USDA Forest Service Rocky Mountain Research Station, Research Paper RMRS-RP-4, 1998, revised 2004, DOI 10.2737/RMRS-RP-4). That paper states its purpose plainly: it explains how the simulation was built and how the individual models inside it perform under simplified test conditions. It is a model description and an evaluation, not a field manual.

FARSITE does not invent new fire physics. It combines existing models of surface fire spread, crown fire spread, spotting (new ignitions ahead of the front from firebrands), point-source fire acceleration and dead fuel moisture, and it handles the geometry of growth over a landscape. Two words in the description matter for anyone reading a FARSITE result as a research output:

  • Two-dimensional: the fire is a perimeter drawn on a map. The model has no representation of the atmosphere above the fire.
  • Deterministic: the same inputs produce the same perimeters. Any uncertainty in the result comes from the inputs and from the component models, not from random draws inside the model.

The Wildland Fire Decision Support System (WFDSS) help page for “FARSITE (Near Term)” describes FARSITE as a module within FlamMap 6 (Basic), and says it uses hourly weather over the specified burn period or periods. It lists the products as wind vectors, spread vectors, fire perimeters and raster maps of fire behavior characteristics for the simulation footprint. The model description below follows the 1998/2004 research paper, so version-specific details of current software should be checked against the software’s own documentation.

How FARSITE works in practice

Perimeter growth by Huygens’ principle

FARSITE represents the fire edge as a polygon of vertices. It propagates that perimeter with a vector method based on Huygens’ principle: each vertex acts as a source of a small elliptical wavelet, and the new perimeter is the outer envelope of those wavelets. The shape and orientation of each ellipse come from the combined wind and slope vector, using a simple ellipse form attributed to Van Wagner (1969). Surface spread rate comes from the Rothermel (1972) equation. The user controls the space and time resolution of the simulation.

What a run produces

The output is a set of vector fire perimeters at specified time intervals. Each vertex carries a spread rate and a fireline intensity, and these are interpolated to raster maps of fire behavior. A time-of-arrival raster is built by inverse distance weighting. The data table below lists the spatial inputs and what each feeds.

Weather, wind and fuel moisture

In the original model description the weather stream is daily minimum and maximum temperature and humidity plus precipitation at a specified elevation, with the diurnal pattern following a cosine curve. Temperature is adjusted for elevation using a lapse rate of 1 °C per 100 m, and precipitation is treated as spatially constant. Wind is an event-driven stream of wind speed, direction and cloud cover, assumed uniform over the landscape portion being simulated. Because both streams are applied across the landscape, the paper notes that weather typically comes from a few representative stations.

Fuel moisture works differently. The user supplies initial dead and live fuel moisture by fuel model, and a conditioning period of days or weeks ahead of the simulation lets the model move 1-hour and 10-hour dead fuel moisture using the BEHAVE moisture model (Rothermel and others, 1986). The influence of the starting values fades as simulated time passes, which is why a conditioning period is part of the method rather than an optional extra.

Crown fire and spotting

For crown fire the model uses Van Wagner’s (1977) passive, active and independent classification, but independent crown fire is not incorporated in FARSITE. Active crown fire spread rate follows the Rothermel (1991) correlation (3.34 times the surface spread rate R10, with a 0.4 wind reduction factor), and an active crown fire needs a supporting surface fire. Spotting follows Albini (1979) for torching trees; the simulation is restricted to the contact locations of standard firebrands because few ember-production studies exist, and spot fires are assumed to burn independently of one another.

Acceleration

A fire that starts from a point takes time to reach its equilibrium spread rate. FARSITE includes an acceleration component for this: slower acceleration produces smaller fires, so the acceleration assumption affects early-time perimeters directly.

Model components, what they assume and what they leave out

The comparison below is compiled from the Finney paper. It puts each component’s basis next to its stated assumption or restriction, so a reader can see where a particular FARSITE result is leaning on a simplification.

Component Basis in the paper Stated assumption or restriction
Perimeter growth Huygens’ principle with elliptical wavelets; Van Wagner (1969) ellipse Fire behavior at each vertex is treated as independent of the others
Surface fire spread Rothermel (1972) equation Fuel is described by a fuel model (Anderson 1982 fuel models are cited)
Crown fire Van Wagner (1977, 1993); Rothermel (1991) Independent crown fire not incorporated; active crown fire needs supporting surface fire; could not be verified against empirical data under the paper’s restricted test conditions
Spotting Albini (1979) torching-tree model Restricted to contact locations of standard firebrands; spot fires assumed independent; could not be verified against empirical data under the paper’s test conditions
Dead fuel moisture BEHAVE moisture model (Rothermel and others, 1986) Needs user-supplied initial moisture and a conditioning period
Weather Cosine diurnal curve; elevation lapse rates Precipitation spatially constant; wind uniform over the landscape portion; few stations
Atmosphere Not modeled No fire-atmosphere feedback

FARSITE sits among several different kinds of fire tools, and conflating them is a common source of confusion in methods sections.

  • Fire behavior at a point versus fire growth over an area. Rothermel-type spread equations give a rate at one location under given conditions. FARSITE’s contribution is to run that behavior across a landscape and through time to produce a growing perimeter.
  • Landscape data versus the model. The fuel, canopy and terrain rasters are inputs prepared elsewhere. The CASRAI guide to forest management gives context on the stands and fuel conditions those rasters describe.
  • Fire danger versus fire growth. Rating systems indicate potential for fires to start and spread on a given day; a growth simulation projects the path of a specific fire. See fire danger for the rating side.
  • Fire growth models versus monitoring. Satellite and sensor tools observe fires that are already burning; see FIREMON for a monitoring and inventory protocol.

Where it matters for research and for research offices

A FARSITE run is only as good as the rasters and weather behind it, so the research-practice question is what to record. The Finney paper treats these as the spatial inputs: elevation, slope, aspect, fuel model, canopy cover, crown height, crown base height and crown bulk density, with raster resolutions of 25 to 50 m the most commonly available and seen as an acceptable level of detail. A publication or data package that uses FARSITE output should therefore report the sources and resolutions of those themes, the weather and wind streams and stations used, the starting fuel moisture and conditioning period, and the simulation time and space steps, so that another group can rerun it. The principle is the one described under methods reproducibility.

The same paper is also a guide to what not to claim. It states that plume-dominated fires, fire whorls and mass fires cannot be reliably modeled, and that the crown fire and spotting simulations could not be verified against empirical data under its restricted test conditions. A study that reports FARSITE perimeters for such a fire, or presents crown-fire or spotting output as validated, goes beyond what the model’s own documentation supports.

Common misunderstandings

“FARSITE predicts where a fire will go”

It projects growth conditional on the supplied terrain, fuel, weather and wind. A different weather stream gives a different perimeter, and the model does not forecast the weather itself.

“It models the smoke plume and fire weather it creates”

It does not. The paper lists the absence of fire-atmosphere feedback as a limitation, and plume-dominated fires are outside what it can reliably model.

“Finer rasters always mean better output”

The paper names 25 to 50 m rasters as commonly available and acceptable. It does not claim that finer resolution removes the other limitations, such as uniform wind and independent vertices.

“FARSITE is the file system”

The name is shared with an unrelated distributed file system in computer science (the USENIX OSDI 2002 paper). Searches for the fire model are best qualified with “fire”, “wildland” or “Finney”.

“FARSITE is a standalone download”

The WFDSS help describes it as a module within FlamMap 6 (Basic). Check the current software documentation for packaging and version details rather than relying on older descriptions.

Sources

  • Finney, M.A. 1998 (rev. 2004). FARSITE: Fire Area Simulator: model development and evaluation. USDA Forest Service, Rocky Mountain Research Station, Research Paper RMRS-RP-4. DOI 10.2737/RMRS-RP-4. research.fs.usda.gov/treesearch/4617 (read 2026-11-18).
  • Wildland Fire Decision Support System help, “FARSITE (Near Term)”, page last modified 2024-10-22. wfdss.firenet.gov (read 2026-11-18).
  • Finney, M.A. and Andrews, P.L. 1998. Application and status of the FARSITE fire area simulator. Proceedings, III International Conference on Forest Fire Research / 14th Conference on Fire and Forest Meteorology, Luso, Portugal, 16 to 20 November 1998, pp. 755-760 (cited as further reading).

Data: FARSITE spatial input themes and the model component each feeds

Compiled from Table 1 and the model-development sections of Finney's FARSITE research paper (RMRS-RP-4): each GIS raster theme, how FARSITE uses it, and the cited basis. Compiled 2026-11-18.

Period covered: 1998/2004.

FARSITE spatial input themes and the model component each feeds
Raster themeHow FARSITE uses itCited basis in the paper
ElevationAdiabatic adjustment of temperature and humidity from the reference elevationWeather stream elevation adjustment
SlopeCombines with wind to set the spread ellipse and directionRothermel (1972); wind-slope vector
AspectSolar incidence angle and surface-to-horizontal transformTerrain geometry
Fuel modelSurface fuel description: loadings by size class and dead/live, surface-area-to-volume ratios, bulk depthAnderson (1982); Rothermel (1972)
Canopy coverShading and the wind reduction factor from a 6.1 m reference height above vegetationCanopy and wind adjustment
Crown heightDescribes canopy structure for crown fireVan Wagner (1977)
Crown base heightCrown-fire transition together with fireline intensity and foliar moistureVan Wagner (1977)
Crown bulk densityThreshold for active crown fireVan Wagner (1977, 1993)

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about FARSITE: Fire Area Simulator, How the Model Works, Inputs and Limits

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →