Written and maintained by CASRAI Editorial Board
Published · Last updated
On this page
General information from FDA pages, not medical or regulatory advice for any individual device or patient. Sources checked 2026-11-01.
Short answer
An FDA safety communication is a public notice on FDA’s Medical Device Safety pages that, in FDA’s words, describes the agency’s analysis of a current issue and gives regulatory approaches and clinical recommendations for patient management. It is one of several FDA channels for medical device alerts. It is not the same thing as a recall entry, an early alert, or a letter to health care providers.
What an FDA safety communication is
FDA publishes safety communications (the plural, “FDA safety communications”, is the name of the list) on its Safety Communications page. The page lists entries by date posted, and each entry is labelled with a Product Area, for example Joint Replacement, Blood Glucose Monitoring System, Pacemakers, Patient Monitors, Diabetes Devices or In Vitro Diagnostics. Older entries sit under “Previous Safety Communications” (2024, 2023, and an archive for 2011-2022). Some entries are also offered in Spanish, Simplified Chinese and Tagalog.
For a worked example of how one safety communication connects to a recall record in practice, see our guide to the glucose meter recall.
Safety communication vs early alert vs recall vs provider letter
FDA’s Medical Device Safety hub groups these channels side by side. The table below states only what FDA’s own pages say about each one.
| Channel | What FDA says it is | Where it lives |
|---|---|---|
| Safety communication | FDA’s analysis of a current issue, with regulatory approaches and clinical recommendations for patient management | Safety Communications page |
| Early alert | A posting about corrective actions a company is taking that FDA believes are likely the most serious type of recall; the status column shows whether FDA is still collecting information | Medical Device Recalls and Early Alerts page |
| Recall entry | An entry in the same recalls and early alerts table whose status is “Recall Confirmed” | Medical Device Recalls and Early Alerts page |
| Letter to health care providers | Listed as its own item on the Medical Device Safety hub | Medical Device Safety hub |
| Medical Device Reporting (MDR) and MedSun | Listed on the hub as “How to Report Medical Device Problems” and the Medical Product Safety Network; FDA monitors reports of adverse events and other problems with medical devices | Medical Device Safety hub |
The practical difference: a safety communication explains an issue and what FDA recommends, while the recalls and early alerts table tracks the corrective action itself. For recall classes and records, see medical device recall; for searching classified recalls, see FDA enforcement reports.
How to find and subscribe to medical device alerts
The Safety Communications page carries a sign-up box for email updates on “medical device recalls, safety communications, and other safety information”, and RSS feeds are linked. FDA states it will keep the public informed and update its website as significant new information becomes available. Adverse events you observe are a separate path: see FDA MedWatch.
Reading an entry
“UPDATE:” in the title
FDA marks updated communications with an “UPDATE:” (or “Update:”) prefix in the title. An older notice you saved may have been superseded, so check the current title and date.
Product Area
The Product Area label is the quickest filter for matching an entry to the equipment you hold.
Status: Early Alert or Recall Confirmed
In the recalls and early alerts table, the status column reads “Early Alert – FDA collecting information” or “Recall Confirmed”, next to the date, issue title and product area. An early alert status means FDA is still collecting information, while Recall Confirmed means the recall has been confirmed.
Building a check into your equipment records
This routine is an editorial suggestion built on the features FDA describes above, not an FDA requirement.
- Subscribe to FDA’s email updates or RSS feed for recalls and safety communications.
- List the Product Areas that match the devices you keep, using the labels FDA uses.
- When an entry appears in one of those areas, compare it with your equipment inventory.
- Record the entry title, date and the action your facility took, then check the recall status for the same issue in the recalls and early alerts table.
Common misunderstandings
- A safety communication is not automatically a recall. FDA lists them as separate channels with separate pages.
- An early alert is not a confirmed recall. The status column distinguishes the two.
- Older entries can be updated. Look for the “UPDATE:” or “Update:” prefix and the archive years.
FAQ
What is an FDA safety communication?
A notice describing FDA’s analysis of a current device issue, with regulatory approaches and clinical recommendations for patient management.
Where do I find FDA safety communications?
On FDA’s Safety Communications page under Medical Device Safety, listed by date posted with a Product Area for each entry.
How do I get medical device alerts by email?
Use the email update sign-up on the Safety Communications page, or the RSS feeds it links.
Sources
- FDA, Safety Communications, checked 2026-11-01.
- FDA, Medical Device Safety, checked 2026-11-01.
- FDA, Medical Device Recalls and Early Alerts, checked 2026-11-01.