Skip to main content
v2026.11,986 entries · CC-BY 4.0

Fracture Mechanics: K, G, J and the ASTM Tests

How fracture mechanics links flaw size, toughness and stress, with a worked example and a comparison of the main ASTM fracture test methods.

Written and maintained by CASRAI Editorial Board

Published

On this page

Fracture mechanics is the branch of solid mechanics that treats a crack or flaw as part of the structure and asks when it will grow. Its central result links three quantities: the size of the defect, the material’s resistance to cracking (its fracture toughness or crack growth rate), and the applied stress. If any two are known, the third can be estimated. Laboratories use it to measure toughness and fatigue crack growth rate on precracked specimens under ASTM standards, and engineers use those measurements to decide whether a flaw is tolerable.

Definition and scope

Ordinary strength calculations assume a sound, uncracked body and compare stress with yield or ultimate strength. Fracture mechanics starts from the opposite assumption: a crack exists, and the question is whether it stays put, grows slowly, or runs unstably. ANSYS’s mechanical documentation describes it as the field that “accounts for the cracks or flaws in a structure” (vendor documentation, read 2026-11-13). A 1986 NASA contractor report on fracture mechanics life technology states the core idea most directly: the equations “effectively link three parameters — the defect size, the material/environment’s intrinsic fracture toughness or sub-critical crack growth rate, and the applied stress, so that if any two of these are known, the third can be quantified.”

The field is usually traced to A. A. Griffith, who developed an energy-based explanation of why brittle materials such as glass fail well below their theoretical strength. His glass experiments with artificial surface cracks found that the product of the square root of flaw length and the stress at fracture was nearly constant. Later work by G. R. Irwin and colleagues at the U.S. Naval Research Laboratory brought in plasticity for ductile metals and introduced the stress intensity factor, K, which Irwin related to Griffith’s energy release rate (Wikipedia, “Fracture mechanics”, read 2026-11-13; the page is a secondary summary, so treat the attribution as background rather than a citation for the physics).

This page covers the concepts a laboratory needs in order to read a fracture test report: loading modes, K, G, J, the critical flaw size relation and its fatigue analogue. It does not reproduce the validity criteria of the test standards, which are in the standards themselves.

How fracture mechanics is used in practice

Crack-tip loading modes

Near a crack tip only three kinds of relative movement of the crack faces occur. In Mode I the faces are pulled apart (opening or tensile mode); in Mode II they slide over one another perpendicular to the leading edge (shearing mode); in Mode III they tear parallel to the leading edge (out-of-plane tearing). The NASA report notes that Mode I is generally regarded as by far the most common, and ANSYS notes that real fractures are usually a combination of modes. For that reason most standard toughness tests are Mode I tests.

The stress intensity factor K

For each mode, a stress intensity factor K sets the magnitude of the stress field near the crack tip. In the NASA report’s notation for a Mode I crack, K = σ·F·√(πa), where σ is the applied stress (kept below yield, σ < σy), a is the crack length, and F is a dimensionless correction factor that depends on flaw size, geometry, loading mode, stress gradients and boundary conditions. F equals 1 for a centre-cracked, infinitely wide plate under uniform tension, where a is the half-length of the crack. When K reaches a critical value Kc, the crack extends in an unstable manner. A material’s Kc, measured under plane-strain conditions, is reported as the plane-strain fracture toughness KIc.

Because K combines stress and crack size in one number, a short crack at high stress and a long crack at low stress can be equally severe. That is why a toughness value measured on a laboratory specimen can be applied to a part with a different geometry, provided the correction factor F is handled properly.

Worked illustration: critical flaw size

If Kc is treated as a fixed property and F is roughly constant, rearranging the fracture condition gives a critical flaw size, ac = (1/π)(Kc/σ)² (NASA report, Eq. 1-2). The numbers below are hypothetical and chosen only to show the arithmetic; they are not data for any real material.

  • Assume Kc = 50 MPa√m, σ = 200 MPa and F = 1 (the centre-crack plate case above).
  • Kc/σ = 0.25 √m, so (Kc/σ)² = 0.0625 m, and ac = 0.0625/π ≈ 0.0199 m, or about 20 mm.
  • Doubling the stress to 400 MPa gives (0.125)² = 0.015625 m and ac ≈ 0.0050 m, about 5 mm. Critical flaw size falls with the square of the stress, so a doubling of stress cuts it to a quarter.

The practical reading is the one the NASA report states: with two of the three parameters fixed, the third follows. If a lab measures Kc and the design stress is set, the largest tolerable flaw is the unknown that inspection must be able to detect.

Energy release rate G and the J-integral

The second criterion is energetic. The energy release rate G is the potential energy released as the crack advances; fracture occurs when G reaches a critical value Gc. In linear elastic fracture mechanics (LEFM) the K and energy criteria are equivalent in some circumstances (ANSYS documentation). For a thin plate, the Griffith result is G = πσ²a/E, where E is Young’s modulus. The J-integral extends the energy idea to nonlinear elastic-plastic materials; ANSYS describes it as one of the most widely accepted fracture mechanics parameters, and for a linear elastic crack it equals the energy release rate.

Fatigue crack growth

Cracks can also grow below the critical level. In fatigue, the growth per cycle is a function of the stress intensity factor range: da/dN = f(ΔK), where ΔK = Kmax − Kmin = (1 − R)Kmax and R is the ratio of minimum to maximum load. For stress corrosion and creep, the growth rate per unit time is a function of K: da/dt = g(K). Integrating from an initial flaw size ai to a final size af, or to ac, gives a life estimate. The NASA report observes that the final flaw size usually has very little effect on life compared with the initial flaw size, which is why the size of the flaw you can reliably find at inspection matters so much.

In the laboratory, the standard way to characterise a material is a specimen with a saw-cut slot, cycled at low stress until a fatigue crack grows out of the slot. Crack length is recorded against cycle count, converted to growth rate, and plotted as da/dN against ΔK on logarithmic axes. The same logic of a fatigue-grown, sharp starter crack underlies the precracking required by the toughness standards below.

Linear elastic versus elastic-plastic fracture mechanics

LEFM works when the plastic zone at the crack tip is small relative to the crack length and the specimen. When the material yields substantially at the tip, as many ductile metals do, K alone no longer describes the situation and parameters such as J or crack-tip opening displacement (CTOD, δ) are used. A secondary source adds that plastic deformation blunts the crack and that LEFM is of limited use for structural steels that deform plastically (Wikipedia, read 2026-11-13). This distinction is the reason there are several ASTM toughness standards rather than one.

Which ASTM standard answers which question

The data table below compares four ASTM test methods, each read from its ASTM store page on 2026-11-13. In brief: E399 is the route to plane-strain KIc for metals behaving mainly in a linear-elastic way; E1820 covers K, J and CTOD for elastic-plastic behaviour and sends KIc determinations to E399; E647 measures fatigue crack growth rate; and E1921 handles the cleavage transition range of ferritic steels. Each requires fatigue-precracked specimens or an equivalent sharp crack, and each has validity conditions that are in the standard and are not repeated here. A report that quotes a toughness value without naming the method and edition is incomplete.

Where it matters for labs

For a laboratory, fracture mechanics is mostly a matter of choosing the right test and recording enough to make the result reusable.

  • Match the method to the material behaviour. A brittle or high-strength metal that stays mainly elastic points to E399. A tougher metal that yields at the tip points to E1820. A ferritic steel being assessed across its ductile-to-brittle transition points to E1921. Slow crack growth under cycling points to E647.
  • Specimen thickness and type are part of the result. E399 applies to fatigue-precracked specimens of thickness 1.6 mm (0.063 in.) or greater and notes that there is no standard method for thinner brittle materials. E647 allows compact, middle-tension and eccentrically loaded single-edge crack tension specimens.
  • Keep the crack-length record. Fatigue growth rate depends on a crack length-versus-cycles record; without it da/dN cannot be reconstructed.
  • Report the method, edition and temperature. E1921, for example, is defined for a stated loading-rate range (0.1 < dK/dt < 2 MPa√m/s) and yield strengths of 275 to 825 MPa.

Fracture mechanics also links to other pages on this site. Environmental cracking is treated by the same da/dt = g(K) logic; see the guides on stress corrosion cracking and hydrogen embrittlement. The more basic stress, strain and tensile-testing concepts are in the solid mechanics guide, and the wider field is introduced in what is materials science.

Common misunderstandings

  • “Fracture toughness is the same as Charpy energy.” It is not. A Charpy impact test reports absorbed energy in joules for a notched bar, a different quantity from K, which is a stress-field amplitude with units of MPa√m. Charpy results rank materials; they are not substituted directly into the K equations.
  • “A higher yield strength means a tougher material.” The two are separate properties. The fracture equations are stated for stresses below yield, and strength alone does not tell you the critical flaw size.
  • “Kc is a single number for a material.” The NASA report’s critical flaw relation assumes Kc is a fixed property, and says so as an assumption. In practice, toughness depends on thickness, temperature and loading rate, which is why the standards specify them.
  • “The final crack size decides the life.” For fatigue, the initial flaw size has far more influence on life than the final size, per the NASA report.
  • “LEFM applies everywhere.” It applies when the plastic zone is small. Outside that, J or CTOD methods are needed.
  • “The NASA report is the current method.” That report dates from 1986. It is cited here for the underlying relations, not for current testing practice, which is in the current ASTM editions.

FAQ

What is fracture mechanics in simple terms?

It is the study of how and when a crack in a material or structure will grow, using the crack size, the material’s toughness or crack-growth behaviour, and the applied stress.

What do K, G and J mean?

K is the stress intensity factor, the amplitude of the stress field near a crack tip. G is the energy release rate as the crack advances. J is the J-integral, an energy-based parameter that also applies to elastic-plastic materials and equals G for a linear elastic crack.

Which ASTM standard measures plane-strain fracture toughness?

ASTM E399 determines KIc for metallic materials under mainly linear-elastic plane-strain conditions. E1820 covers K, J and CTOD where behaviour is elastic-plastic and refers KIc determinations to E399.

How is fatigue crack growth measured?

ASTM E647 measures da/dN against ΔK on precracked specimens, from near-threshold growth to instability controlled by Kmax.

What is the difference between Mode I, II and III?

Mode I is opening, Mode II is in-plane shearing and Mode III is out-of-plane tearing. Mode I is generally the most common.

Sources

  • Besuner, P. M., Harris, D. O., Thomas, J. M. A Review of Fracture Mechanics Life Technology, NASA Contractor Report 3957, February 1986, sections 1.2-1.3. NASA NTRS. Read 2026-11-13.
  • ANSYS Mechanical APDL documentation, “Introduction to Fracture Mechanics” (vendor documentation). ANSYS Help. Read 2026-11-13.
  • ASTM E399-23, Standard Test Method for Linear-Elastic Plane-Strain Fracture Toughness of Metallic Materials. ASTM. Read 2026-11-13.
  • ASTM E1820-23, Standard Test Method for Measurement of Fracture Toughness. ASTM. Read 2026-11-13.
  • ASTM E647-23, Standard Test Method for Measurement of Fatigue Crack Growth Rates. ASTM. Read 2026-11-13.
  • ASTM E1921-23, Standard Test Method for Determination of Reference Temperature, T0, for Ferritic Steels in the Transition Range. ASTM. Read 2026-11-13.
  • Wikipedia, “Fracture mechanics” (secondary background for history and LEFM validity). Read 2026-11-13.

Data: ASTM fracture and fatigue crack growth test methods compared: what each measures and its scope limits

Compares four current ASTM test methods used in fracture mechanics laboratories by quantity measured, material class, specimen types and scope limits. Compiled from the scope statements on each standard's ASTM store page, read 2026-11-13.

Period covered: 2023 editions.

ASTM fracture and fatigue crack growth test methods compared: what each measures and its scope limits
StandardTitleQuantity measuredMaterial or regimeSpecimen types or scope limit
ASTM E399-23Standard Test Method for Linear-Elastic Plane-Strain Fracture Toughness of Metallic MaterialsKIc (mandatory); KIsi optional (Appendix X1)Metallic materials under mainly linear-elastic plane-strain conditionsFatigue-precracked specimens, thickness 1.6 mm (0.063 in.) or greater; no standard method for thinner brittle materials; cleavage referred to E1921, elastic-plastic to E1820
ASTM E1820-23Standard Test Method for Measurement of Fracture ToughnessK, J and CTOD (delta); R-curve or single-point valuesMetallic materials, Mode I, elastic-plastic behaviourSE(B), C(T) and DC(T) specimens with fatigue-precracked notches; KIc no longer evaluated under E1820, referred to E399
ASTM E647-23Standard Test Method for Measurement of Fatigue Crack Growth Ratesda/dN versus delta-KNear-threshold (region I) to Kmax-controlled instability (region III); delta-K defined by linear elasticityCompact (A1), middle tension (A2) and eccentrically loaded single edge crack tension (A3) specimens; any thickness or strength provided no buckling and predominantly elastic behaviour
ASTM E1921-23Standard Test Method for Determination of Reference Temperature, T0, for Ferritic Steels in the Transition RangeReference temperature T0 from cleavage KJc instabilitiesFerritic steels, yield strength 275 to 825 MPa, ductile-to-brittle transition rangeSE(B) and C(T) or DC(T) fatigue-precracked specimens; quasi-static loading rate 0.1 < dK/dt < 2 MPa sqrt(m)/s; weld metal after stress-relief if strength mismatch is 10% or less

Sources

Compiled by CASRAI from the sources above. Free to reuse under CC BY 4.0 with attribution.

Follow CASRAI

Research-administration guidance, standards updates and independent tool reviews.

Ask CASRAI · full access

Ask about Fracture Mechanics: K, G, J and the ASTM Tests

Full access: large monthly usage, up to 10 source passages behind each answer, and MCP and API access for Claude Code, Codex and other CLIs. Cancel any time.

An AI assistant for research: funder rules, compliance, methods and publishing. It links the sources behind its answers and labels answers that come from a web search.

Answers draw on CASRAI's guides and dictionary plus the federal and funder documents we index: Federal Register, Grants.gov, Regulations.gov and UKRI.

Works on this site and inside Claude, Cursor and the AI tools you already use.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays open to read, with no account and no card.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →